C1DA--Project # 596A4-27-101 - A/E Upgrade Fire Alarm System

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

249-NETWORK CONTRACT OFFICE 9 (36C249)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24927R0019

NAICS

541330 - Engineering Services

Classification Code

C1DA

Additional Details
Set Aside

SDVOSBC

Place of Performance

Lexington, Kentucky, UNITED STATES

SourceSAM
Documents1
The Department of Veterans Affairs, through its Network Contract Office 9 (36C249), has issued a presolicitation notice for Architect/Engineering (A/E) Design Services under project number 596A4-27-101, titled "A/E Upgrade Fire Alarm System." This opportunity is specifically set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC) and is governed by NAICS code 541330 (Engineering Services), with a small business size standard of $25.5 million. The place of performance is the Lexington VA Healthcare System, Troy Bowling Campus, located in Lexington, Kentucky. Purpose and Scope: The primary objective of this procurement is to secure comprehensive A/E design services for the replacement and upgrade of the fire alarm system across multiple facilities at the Troy Bowling Campus, including Building 1, Building 1A, and Building 4. The scope encompasses hospital spaces, a parking garage, and crawl spaces, covering a total facility area of 537,542 square feet. The new fire alarm system must be designed to interface with various hospital systems such as door magnets, elevators, HVAC, kitchen hood systems, sprinkler and specialty fire suppression systems, door locking mechanisms, smoke dampers, duct detectors, and other related systems. The project aims to address and correct several Facility Condition Assessment (FCA) deficiencies, specifically items 338139, 45058, 49003, 49909, 49035, 49963, and 49935. Key Requirements and Deliverables: - The selected A/E firm will conduct thorough field investigations, including above-ceiling surveys, with VA assistance for access. - The existing fire alarm system must remain operational until the new system is fully functional, requiring careful phasing and cutover planning by the A/E. - The firm will be responsible for validating and supplementing limited digital as-built documentation, including independent review of hard copy drawings and flat files. - Design documents must comply with all applicable VA standards, codes, and program guides, ensuring the medical center remains operational throughout construction with minimal disruption. - Drawings and specifications must be detailed enough for qualified general contractors to prepare accurate proposals. - The A/E must provide a detailed sequence of work to minimize impact on hospital operations. - The estimated construction magnitude for this project is between $10,000,000 and $20,000,000. - The total cost of A/E services contracted must not exceed 6% of the estimated construction cost, per VAAR 836.606-73. - The firm must maintain a four-hour response time during both the design and construction period services phases. Contracting and Submission Details: - The procurement will follow the Brooks Act and FAR Part 36.6, with selection based on demonstrated competence and qualifications. - Only SDVOSBCs verified by the SBA and visible in the DSBS database at the time of submission, interview, and award will be considered. - Interested firms must submit their SF-330 Architect/Engineer Qualifications package electronically to Matthew Whisman ([email protected]) by December 3, 2026, at 2:00 PM EST. Submissions are limited to 50 pages and must adhere to specified electronic formats; .zip files and password-protected documents are not permitted. - The contract will be awarded as a Negotiated Firm-Fixed Price Contract. - All architectural, structural, mechanical, electrical, civil, or other engineering features must be reviewed/designed by professionals registered in a U.S. state, Puerto Rico, or the District of Columbia. Selection Criteria: Firms will be evaluated based on: - Professional qualifications for satisfactory performance - Specialized experience and technical competence, including energy conservation and sustainability - Capacity to accomplish the work within required timelines - Past performance with government and private contracts - Knowledge of the local area and proximity to the project site - Reputation and standing of the firm and its principals - Record of significant claims due to improper or incomplete services - Experience and qualifications of proposed personnel and their teamwork history Special Considerations: - The solicitation is strictly for SDVOSBCs; non-qualifying firms will not be considered. - The awarded A/E firm cannot be awarded the construction contract for the same project, per FAR 36.209, unless specifically approved. - The medical center must remain fully operational during construction, requiring careful planning and sequencing. - All submissions must be virus-free and readable; unreadable or infected files will be treated as non-responsive. Contact Information: Primary contact for this opportunity is Matthew Whisman, reachable at [email protected] or 859-281-3883. Additional details and the SF-330 form can be accessed via the GSA Forms Library or the official SAM.gov opportunity page (https://sam.gov/opp/fe55df3f1a75416f8dac41214550e0eb/view). This presolicitation notice represents a significant opportunity for qualified SDVOSBC A/E firms with relevant experience in fire alarm system upgrades for healthcare facilities. Firms should carefully review the requirements and ensure compliance with all submission and verification protocols to be considered for this contract.