J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

245-NETWORK CONTRACT OFFICE 5 (36C245)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24527Q0061

NAICS

561210 - Facilities Support Services

Classification Code

J065

Additional Details
Set Aside

None

Place of Performance

-

SourceSAM
Documents1
The Department of Veterans Affairs (VA), through its Network Contract Office 5 (NCO 5), has issued a presolicitation notice for HVAC upgrades at the VA Maryland Health Care System (VAMHCS), specifically targeting Building 1 Community Living Center (CLC) at the Loch Raven Campus. This solicitation, identified by procurement number 36C24527Q0061, seeks a qualified contractor to provide comprehensive facilities support services under NAICS code 561210 (Facilities Support Services), with a product service code of J065. Purpose and Scope: The primary objective of this procurement is to enhance the HVAC infrastructure within designated areas of the CLC, ensuring improved air quality, operational efficiency, and compliance with VA and industry standards. The scope encompasses both mechanical upgrades and integration with existing building automation systems, with a focus on critical areas such as the Covid Ward (2nd floor B wing) and the kitchen basement. Key Requirements and Deliverables: The contractor will be responsible for furnishing all necessary materials, labor, equipment, and supervision to complete the following tasks: - Covid Ward (2nd floor B wing): - Upgrade exhaust fans and air handling unit (AHU-B) located in the attic. - Replace and upgrade exhaust fans EF-1A and EF-1B for higher CFM outputs. - Install heat tracing for chillers, including wiring and junction box work in room G-15, and coordinate termination to an emergency electrical panel in G-17 (panel selection TBD). - Install a 20-amp GFPE circuit breaker for heat tracing. - Kitchen Basement: - Replace cooling coil(s) and fan motor in AHU-E (located in attic), ensuring the new motor is rated for 60Hz fan speed. - Replace the variable frequency drive (VFD) attached to AHU-E with an ABB-manufactured unit. - Controls Integration: - Coordinate with the VA’s existing Johnson Controls International (JCI) contract to ensure seamless integration with the facility’s Building Automation System (BAS). - Provide or update hardware and connections for BAS monitoring as required. - Testing, Adjusting, and Balancing (TAB): - Conduct TAB post-modification, performed by a certified vendor per TABB or other ANAB-accredited programs. - Notify and request attendance of the Contracting Officer’s Representative (COR) for TAB activities. - Submit TAB reports for VA review and approval prior to contract closeout and final payment. - Warranty, Operations & Maintenance (O&Ms), and Shop Drawings: - Provide warranty documentation covering workmanship, materials, and equipment, with a designated point of contact. - Submit O&M manuals for all new equipment and components requiring preventative maintenance. - Deliver training to VA staff on new systems. - Update as-builts, shop drawings, and manufacturer diagrams as applicable, subject to COR determination. Administrative and Compliance Considerations: - Contractors must provide cost/unit for each deliverable and track quantities in pay applications, with unused amounts returned to the government. - Pay applications must not exceed the purchase order balance; contract modifications are required for overages. - Additional work outside the contract scope requires written authorization from the Contracting Officer (CO). - Compliance with VA guidelines, federal and state codes, and industry standards is mandatory. - Contractors are responsible for maintaining cleanliness and stewardship of work areas, including attics and mechanical spaces. - Adherence to VA permitting, safety practices, and risk assessments (ICRA, PCRA, LOTO, PPE, etc.) is required. - Parking is limited and subject to facility guidelines; coordination is necessary for work impacting patient care or utilities, with a minimum 14-day written notice for shutdowns. Contracting Entity and Contact Information: The contracting entity is the VA’s Network Contract Office 5 (NCO 5), a federal office under the Department of Veterans Affairs. The primary point of contact for this solicitation is Keysha Gorman, who can be reached at [email protected]. Location and Period of Performance: All work will be performed at the Loch Raven Campus of the VA Maryland Health Care System, specifically within Building 1 CLC. The period of performance is set at 90 calendar days. Procurement Type and Status: This is a federal solicitation, currently active, with a presolicitation notice posted on December 11, 2026. Responses are due by November 30, 2026. The opportunity is listed on SAM.gov under Opportunity ID fc29e3904eb3405bab37833cd265b531. Contractors interested in this opportunity should carefully review the requirements for HVAC upgrades, BAS integration, compliance, and documentation, ensuring alignment with their technical capabilities and experience in VA medical facility environments. The scope and deliverables are clearly defined, with an emphasis on quality, safety, and operational continuity throughout the contract lifecycle.