6632--Cath Lab GEM 5000

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

246-NETWORK CONTRACTING OFFICE 6 (36C246)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24627Q0130

NAICS

334516 - Analytical Laboratory Instrument Manufacturing

Classification Code

6632

Additional Details
Set Aside

None

Place of Performance

-

SourceSAM
Documents1
The Department of Veterans Affairs, Network Contracting Office (NCO) 6, has issued a Special Notice regarding its intent to negotiate a sole source contract with WERFEN USA LLC for the acquisition of a GEM Premier 5000 Blood Gas Analyzer. This procurement is specifically designated for the Cardiac Catheterization Laboratory at the Durham VA Medical Center (VAMC), and is structured as a reagent rental agreement. Purpose and Scope: The primary objective of this procurement is to equip the Cardiac Cath Lab with a state-of-the-art blood gas analyzer capable of rapid, automated analysis of critical blood parameters. The GEM Premier 5000 system is designed to measure pH, pCO2, PO2, Ca2+, Na2+, K+, lactate, glucose, and hematocrit from whole blood samples, supporting both laboratory and operating room environments. The analyzer will be integrated with the VA VistA hospital information system, ensuring seamless data management and reporting. Reference values for blood gas parameters will be established upon installation to support clinical decision-making. Key Requirements and Deliverables: The contract encompasses the following components and deliverables: - One (1) GEM Premier 5000 analyzer - GEMWEB Plus 500 System for data management - GEM PAKs (self-contained reagent packs that do not require refrigeration) - Consumables including solution and paper printer supplies - Warranty coverage: 12 months standard, with an extended 48-month warranty included A notable feature of the GEM Premier 5000 is its iQM2 with Intraspect technology, which provides real-time quality assurance for every sample analyzed. This system performs checks before, during, and after analysis, enabling immediate, automatic correction and documentation. The all-in-one GEM PAKs facilitate both analysis and quality checks, enhancing reliability and minimizing errors. Contracting Entity and Contact Information: The procurement is managed by the 246-Network Contracting Office 6 (NCO 6), a federal office within the Department of Veterans Affairs. The primary point of contact for this notice is Ayeshia Tucker, who can be reached via email at [email protected] or by phone at 757-315-3956. Classification and Location: - NAICS Code: 334516 (Analytical Laboratory Instrument Manufacturing) - Product Service Code: 6632 - Location: Durham VA Medical Center, under the jurisdiction of NCO 6 Procurement Type and Special Considerations: This acquisition is being conducted as a sole source procurement, justified under Revolutionary FAR Overhaul (RFO) 12. The period of performance includes a base year plus four option years. The notice explicitly states that it is not a request for competitive quotations; no solicitation documents are available, and telephone inquiries will not be accepted. However, businesses that believe they can meet the requirements and possess relevant experience are invited to submit written responses with supporting evidence by 2:30 P.M. EST on November 18, 2026. The government reserves the right to determine whether to compete the acquisition based on responses received. Constant Elements: Throughout the contract lifecycle, the following elements will remain consistent: the requirement for a high-performance blood gas analyzer with integrated quality assurance, the use of GEM PAKs and associated consumables, the extended warranty coverage, and the integration with VA VistA systems. The sole source nature of the procurement and the focus on supporting the Cardiac Cath Lab’s clinical testing needs are also enduring aspects. Summary for Contractors: Contractors evaluating this opportunity should note the specialized nature of the equipment, the integration requirements with VA systems, and the extended warranty provisions. The procurement is limited to WERFEN USA LLC under a sole source justification, but interested parties with demonstrable capability and relevant past performance may submit written evidence for consideration. All inquiries and responses must be directed to the designated contact via email. For further details, the official notice can be accessed at: https://sam.gov/opp/e0c3f331007f43e0887936a919f8ab4a/view