USNS Mercy, Leica Histocore Peloris 3 Maintenance

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

DEPT OF THE NAVY

Contract Value

Not provided

Codes & Classification
Solicitation Number

45110917

NAICS

-

Classification Code

J065

Additional Details
Set Aside

NONE

Place of Performance

San Diego, California, UNITED STATES

SourceSAM
Documents1
The Department of the Navy has issued a Special Notice indicating its intent to award a sole source contract for the provision of preventive maintenance, calibration, and repair services for a Leica Biosystems Histocore Peloris 3 tissue processor onboard the USNS Mercy, homeported at Naval Base San Diego, California. This procurement is critical to ensuring the operational readiness of the USNS Mercy’s Directorate for Clinical Support Services (DCSS), as the tissue processor is essential for processing patient tissue samples during deployments and activation periods. The scope of this requirement encompasses comprehensive on-site preventive maintenance and calibration services, to be performed at twelve-month intervals, in strict accordance with the Original Equipment Manufacturer (OEM) specifications, the Naval Medical Command P-5132 Equipment Management Manual (NAVMED-P5132), local command instructions, and Joint Commission Hospital Accreditation Program requirements. The contractor will be responsible for providing all necessary labor, supplies, and technician transportation to the ship, ensuring that all work is executed by fully qualified field engineers and technicians who have completed OEM training. Proof of such training, including certificates detailing training location, completion, and expiration dates, must be furnished upon request prior to the commencement of any services. The contract is anticipated to cover a base year (01 December 2026 – 30 November 2027) with four additional one-year option periods, potentially extending through 30 November 2031. All work will be performed onboard the USNS Mercy, located at Pier 1, Naval Base San Diego, CA 92136. Key deliverables under this contract include: - Scheduled on-site calibration and preventive maintenance for the Leica Histocore Peloris 3 tissue processor, ensuring consistent and standardized equipment performance. - Submission of detailed Field Service Reports (FSRs) itemizing all maintenance, calibration, and repair activities, to be provided to the government upon completion of each service event. - Provision of all supplemental parts required for calibration and preventive maintenance. - For repairs not covered under routine maintenance, the contractor must obtain prior approval from the USNS Mercy Biomed Medical Repair Section before proceeding. Any such repairs will require a separate purchase order, and all associated costs must be submitted in writing for approval. No modifications to the equipment’s original design or function are permitted without written authorization from both the manufacturer and the Biomedical Repair Division. This notice is not a solicitation for competitive proposals. However, interested parties are invited to submit capability statements demonstrating their technical and management qualifications, relevant experience, and pricing information. Submissions must not exceed five pages and should include business size and CAGE code. All responses must be sent electronically in Microsoft Word or Adobe PDF format to the primary contact, Curtis E. Cardoza ([email protected]), by 2:00 PM local time on 19 November 2026. The procurement is classified under Product Service Code J065 (Maintenance, Repair, and Rebuilding of Equipment—Medical, Dental, and Veterinary Equipment and Supplies). There are no set-aside restrictions associated with this opportunity. This requirement is managed by the Department of the Navy, a federal agency under the Department of Defense. The notice remains active and further details, including any attachments, can be accessed via the official SAM.gov opportunity listing (SAM.gov Opportunity ID: 226a45f9a34e4da8bce5f79110ac7861). Contractors with demonstrated expertise in OEM-certified maintenance of Leica Biosystems equipment, and the ability to meet the stringent requirements of a shipboard medical environment, are encouraged to review the notice and consider submitting a capability statement if interested.