Radiant Heating Panel Replacement

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

NETWORK CONTRACT OFFICE 19 (36C259)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C25927Q0048

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Classification Code

J045

Additional Details
Set Aside

SBA

Place of Performance

Aurora, Colorado, UNITED STATES

SourceSAM
Documents3
The Department of Veterans Affairs, through its Network Contract Office 19 (36C259), has issued a combined synopsis/solicitation (RFQ #: 36C25927Q0048) for the replacement of hydronic radiant heating panels at the Rocky Mountain Regional VA Medical Center (RMRVAMC) in Aurora, Colorado. This procurement is classified under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors), with a small business size standard of $19.0 million, and is set aside exclusively for small businesses. **Purpose and Scope** The primary objective of this contract is to address the failure and corrosion of existing hydronic radiant heating panels located at the main entrances of the RMRVAMC, including the Colfax entrance, South entrance, North entrance, and the employee breezeway from the garage. These failures have resulted in inadequate heating and potential slip hazards. The contractor will be responsible for the one-time removal and replacement of approximately 238 feet of radiant heating panels, ensuring restored and reliable heating at all affected locations. **Key Requirements and Deliverables** The contractor must provide all labor, materials, supplies, tools, equipment, and qualified personnel necessary to: - Remove and dispose of failed heating panels. - Prepare existing locations to prevent future leaks or failure points. - Install new heating panels matching the length, pressure, and connection points of the originals. - Verify proper pressure and leak-free operation of new panels and connections. - Test and confirm full operational restoration. Site-specific requirements include: - Radiators rated for low, medium, and high pressure, with a working pressure of 74 PSIG. - Model PRF radiators, supplied with all mounting brackets for noise-free operation. - Standard ½” female tapered NPT connections and 1/8” female tapered NPT air vent connections. - Radiator expansion not to exceed 0.016 inches at 215°F to accommodate piping expansion and contraction. Contractors must demonstrate prior experience in hydronic heating panel removal and installation, including labor, start-up, and commissioning. They are required to maintain appropriate liability and property damage insurance and take necessary precautions to protect people and property during performance. The government reserves the right to accept or reject contractor personnel based on performance or conduct. A report in Microsoft Word format must be furnished within one week of each space completion, submitted via email to the designated FMS point of contact. **Contract Terms and Conditions** The government anticipates awarding a firm-fixed price contract. Delivery and acceptance are F.O.B. Destination at the RMRVAMC, 1700 N. Wheeling Street, Aurora, CO 80045. The contract incorporates numerous FAR and VAAR clauses, including those related to labor standards, subcontracting limitations, equal opportunity, and electronic payment submission. Contractors must comply with all applicable federal, state, and local regulations. Work is scheduled Monday through Friday, 7:30am to 4:00pm, with minimal impact on medical center operations. Any disruptions must be coordinated in advance with the Contracting Officer (CO) or Point of Contact (POC). Contractor personnel must check in and out with the POC in Building L (ENC). **Submission and Evaluation** Quotes must be submitted electronically (email only, 4MB limit) to Chris Hollingsworth at [email protected] by 2:00pm ET, November 20, 2026. Questions regarding the solicitation are due by 4:00pm ET, November 13, 2026, and will be addressed via amendment. Offerors must submit four volumes: 1. Technical capability/quality to meet requirements. 2. Price, using the provided pricing schedule. 3. Past performance (up to three recent and relevant contracts). 4. Completion of VAAR 852.219-75 (Limitations on Subcontracting Certificate). Evaluation will be based on technical capability, price, past performance, and compliance with subcontracting limitations. The government will use a comparative evaluation process and reserves the right to select a proposal that provides additional benefits beyond minimum requirements. **Contracting Entity and Contact Information** - Contracting Entity: Network Contract Office 19 (36C259), Department of Veterans Affairs - Place of Performance: Rocky Mountain Regional VA Medical Center, Aurora, Colorado, USA - Primary Contact: Chris Hollingsworth, Email: [email protected], Phone: 303-712-5724 **Constant Elements Throughout Contract Lifecycle** - The contract is a firm-fixed price, small business set-aside under NAICS 238220. - All work is performed at the RMRVAMC in Aurora, CO. - Contractor must provide all resources and comply with federal, state, and local regulations. - Strict adherence to reporting, scheduling, and check-in procedures is required. - Payment is made in arrears upon satisfactory completion and proper invoicing. - Compliance with VA records management and training requirements is mandatory. Contractors with relevant experience in hydronic heating panel installation and maintenance, who can meet the technical, scheduling, and reporting requirements, and who qualify as small businesses under NAICS 238220, are encouraged to review the solicitation and consider submitting a quote. For full details and attachments, visit the official notice at [SAM.gov](https://sam.gov/opp/974f9b5eb51f4ade85b43f47c548e773/view).