J061--ELECTRICAL TESTING (SOLICITATION)

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

246-NETWORK CONTRACTING OFFICE 6 (36C246)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24627Q0081

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Classification Code

J061

Additional Details
Set Aside

SBA

Place of Performance

Hampton, Virginia, UNITED STATES

SourceSAM
Documents2
The Department of Veterans Affairs, through its 246-Network Contracting Office 6, has issued a solicitation for a comprehensive three-year contract focused on electrical testing and repair services at the Hampton Veterans Affairs Medical Center in Hampton, Virginia. This procurement, identified by solicitation number 36C24627Q0081, is classified under NAICS code 238210 (Electrical Contractors and Other Wiring Installation Contractors) and product service code J061. The opportunity is set aside for SBA-qualified contractors, emphasizing the agency’s commitment to supporting small business participation. The primary objective of this contract is to ensure the ongoing reliability, safety, and compliance of the medical center’s electrical power distribution system, which operates on a 4160-volt primary system and includes various secondary voltages, as well as both emergency and normal power sources. The scope encompasses a wide range of activities, including inspections, repairs, testing, cleaning, calibrations, and adjustments of electrical equipment and systems. The contractor will be responsible for furnishing all necessary supplies, materials, equipment, labor, and technical supervision to execute these tasks within the contract’s specified timeframe. Key requirements include adherence to the latest standards and codes from ANSI, IEEE, ICEA, NETA, NEMA, NFPA, JCAHO, and VA regulations, as well as compliance with original equipment manufacturer criteria. The contractor must supply all portable power needed for testing, as use of the facility’s normal or emergency power is prohibited. Coordination with Dominion Virginia Power, station supervisory personnel, and VA test personnel is required for scheduling system shutdowns and tests. The VA Medical Center Electrical Staff will manage scheduled outages and reenergizing of circuits, with lockout/tagout procedures performed jointly with the contractor. Testing and repairs are to be conducted primarily outside normal working hours, with outages scheduled at night (5:00 p.m. to midnight) and on weekends (7:00 a.m. to 5:00 p.m.), and contractors should anticipate overtime to ensure timely restoration of power. Testing must be completed within nine consecutive days, beginning on a Saturday and ending the following Sunday, with all outages scheduled two weeks in advance and subject to approval by the Contracting Officer’s Technical Representative (COTR). The contract includes a set-aside line item not to exceed $50,000 for repair or replacement parts, with all repairs invoiced under this line item and paid at actual cost plus markup, up to the specified limit. Prior written approval from the Contracting Officer is required to exceed this amount. The performance work statement details minimum test and inspection requirements for a variety of equipment, including 5 KV air circuit breakers, enclosed air break switches, oil-filled and dry-type transformers, switchgear, low voltage air circuit breakers, oil disconnect switches, molded case circuit breakers, protective relays, instrumentation, watt-hour meters, and transformer/circuit breaker insulating oil. Each equipment type has specific procedures for cleaning, inspection, testing, calibration, and adjustment, with results to be recorded and reported. Contractors must meet stringent qualification criteria. The testing firm must be an independent organization, professionally unaffiliated with equipment manufacturers or suppliers, and a full member of the InterNational Electrical Testing Association (NETA). The firm must have at least five years of experience in electrical testing, with proof included in the proposal. All work must be supervised by a Registered Professional Engineer, and field engineers/technicians must be certified by NICET and/or NETA, with a minimum of five years’ experience. The proposal must include names, certification numbers, and resumes of all personnel involved. The testing organization must maintain a calibration program for test instruments, traceable to NIST standards, with visible calibration labels. A comprehensive equipment list is provided, detailing the types, quantities, and ratings of switchgear, transformers, switchboards, molded case breakers, and associated devices across multiple buildings. Formal reporting requirements include submission of three copies of a comprehensive inspection and testing report, itemized by building, within 30 calendar days of testing completion. Immediate written notification to the COTR is required for any equipment found in a critical state, with recommendations for corrective action. Certification by a Registered Professional Engineer is mandatory. The contracting entity is the 246-Network Contracting Office 6, a federal office within the Department of Veterans Affairs. The primary point of contact for this solicitation is Kenneca B Crump, who can be reached at [email protected]. The solicitation is currently active, with a post date of June 11, 2026, and a response deadline of October 11, 2026. Interested contractors can access the full solicitation and attachments via the SAM.gov opportunity ID ada1bb600cea47db8ae9dd2e7a8adea2. This opportunity is well-suited for experienced electrical testing organizations with the requisite certifications, technical expertise, and capacity to manage complex, large-scale electrical systems in a healthcare environment. The contract’s requirements for after-hours work, strict adherence to industry standards, and comprehensive reporting underscore the VA’s commitment to maintaining a safe and reliable electrical infrastructure for its medical center operations.