J048--NEW - Energy Center Steam Header& Boilers valves, gaskets, and vent replacement

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

257-NETWORK CONTRACT OFFICE 17 (36C257)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C25727Q0078

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Classification Code

J048

Additional Details
Set Aside

SDVOSBC

Place of Performance

Dallas, TX

SourceSAM
Documents1
The Department of Veterans Affairs (VA), through its Regional Procurement Office (RPO) West and Network Contracting Office 17 (NCO 17), is conducting market research via a Sources Sought notice to identify qualified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) and Veteran-Owned Small Businesses (VOSBs) for an upcoming requirement at the Dallas VA Medical Center. This initiative is part of the VA’s VETS First Program and is anticipated to be a total set-aside for SDVOSB and VOSB concerns, in accordance with VA Acquisition Regulation (VAAR) Subpart 819.70. **Purpose and Scope** The primary objective of this procurement is the comprehensive replacement of valves, gaskets, and vent lines on the main steam header and Boilers 1, 2, and 3 at the Energy Center (Building 70) of the Dallas VA Medical Center, located at 4500 S. Lancaster Road, Dallas, TX 75216. The existing components, originally installed in 1994, have reached the end of their serviceable life, impeding effective maintenance and reliable operation. The intended outcome is to restore the integrity and functionality of the steam distribution system, ensuring compliance with current industry standards and supporting the ongoing mission of the VA North Texas Health Care System. **Key Requirements and Deliverables** The selected contractor will be responsible for providing all labor, materials, equipment, supervision, and management necessary to execute the following tasks: - Coordinate equipment shutdowns with the facility representative or Contracting Officer’s Representative (COR) prior to commencing work. - Implement lockout/tagout (LOTO) procedures on all affected equipment to ensure safety. - Remove existing valves, vent lines, and associated components from the main steam header and boilers. - Inspect the interior of the main steam header and check the drip leg for blockages. - Clean flange faces and install new spiral-wound gaskets. - Install new steam valves, steam balancing, and vent lines using Schedule 80 carbon steel piping and full-port, three-piece bolted ball valves (allowing internal access without unthreading from the supply line). - Install new removable high-temperature insulation jackets on all steam valves. - Replace boiler steam stop, isolation, and vent valves, including new vent piping, on Boilers 1, 2, and 3. - Perform leak checks during boiler startup and campus pressurization to 110 psi, in coordination with the COR and Utilities Systems Operator (USO). All replacement components must meet or exceed the specifications of the current installation and comply with applicable steam industry standards and regulations. The anticipated contract type is firm-fixed-price, awarded under FAR Part 12 for commercial products and services. **Contracting Entity and Location** - **Contracting Office:** Department of Veterans Affairs, RPO West | NCO 17, Lab Services Support (LSS), 5441 Babcock Road, Suite 302, San Antonio, TX 78240 - **Place of Performance:** Dallas VA Medical Center, Energy Center (Building 70), 4500 S. Lancaster Road, Dallas, TX 75216 **Classification and Codes** - **Product Service Code (PSC):** J048 – Maintenance, Repair, and Rebuilding of Equipment – Valves - **NAICS Code:** 238220 – Plumbing, Heating, and Air-Conditioning Contractors (Small business size standard: $19.0 million average annual receipts) **Set-Aside and Eligibility** This opportunity is anticipated to be a total set-aside for SDVOSB and VOSB firms. To be eligible, firms must: - Be registered and active in SAM.gov at the time of response and award. - Hold current SBA certification as an SDVOSB or VOSB under 13 CFR Part 128. - Meet the small business size standard for NAICS 238220. **Special Considerations** Given the nature of the work, contractors should be prepared to comply with the Davis-Bacon Act and FAR Part 22, Subpart 22.4 (Construction Wage Rate Requirements). All work must be performed in accordance with applicable safety and regulatory standards. The Government emphasizes that this notice is for market research only and does not constitute a solicitation or a commitment to contract. **Response Instructions** Interested SDVOSB and VOSB firms are invited to submit a capability package (maximum 10 pages) that includes: - Company information (legal name, UEI, CAGE code, addresses, website, and primary contact details) - Business status and certifications (including SBA SDVOSB/VOSB certification details) - Relevant experience with similar steam distribution, boiler, or industrial piping projects within the past three years - Technical capability and staffing, including applicable Texas licenses and welding certifications - Comments or feedback on the scope, NAICS code, or acquisition strategy Responses must be submitted electronically in Word or PDF format to Ognian D. Ivanov, Contract Officer, at [email protected], using the subject line: “Sources Sought – Steam Header and Boiler Valve Replacement – [Company Name]”. The deadline for submission is 2:00 p.m. Central Time on November 9, 2026. Questions must be submitted in writing via email; no telephone inquiries will be accepted. **Contact Information** - **Primary Point of Contact:** Ognian D. Ivanov, Contract Officer - **Email:** [email protected] - **Phone:** 210-694-6302 **Additional Information** This Sources Sought notice is for planning and market research purposes only. No contract will be awarded directly from this notice, and the Government is not obligated to reimburse any costs incurred in responding. If a solicitation is issued, it will be announced separately. All proprietary information should be clearly marked in submissions. For further details and updates, interested parties should refer to the official notice at [SAM.gov Opportunity ID 616b66e8af494e9ba365bdbb907a9176](https://sam.gov/opp/616b66e8af494e9ba365bdbb907a9176).