Inspect and Repair of 13.2KV Main Switchgear

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

USCG ACADEMY

Contract Value

Not provided

Codes & Classification
Solicitation Number

70ZH1526QCGA00009

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Classification Code

J061

Additional Details
Set Aside

SBA

Place of Performance

New London, Connecticut, UNITED STATES

SourceSAM
Documents3
The U.S. Coast Guard Academy, located in New London, Connecticut, is seeking a qualified and licensed electrical contractor to undertake a comprehensive inspection, repair, and restoration of its Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear. This procurement, identified by solicitation number 70ZH1526QCGA00009, is issued as a Combined Synopsis/Solicitation and is currently active, with responses due by December 11, 2026. The primary scope of work centers on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor will be responsible for inspecting Cabinet 5 for any damage or missing/cannibalized components, removing and replacing three Eaton 15CLE-250E fuses, and procuring and delivering three additional matching fuses to be kept as on-site spares. Additionally, the contractor must perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards, ensuring the integrity and safety of the electrical system. Certified test and field-service reports are required as deliverables, documenting all inspection, repair, and testing activities. The contractor must coordinate all necessary outages and lockout/tagout procedures with the Government to ensure safety and minimize operational disruption. Upon successful completion of repairs and testing, the contractor will safely re-energize the cabinet and feeder. All work must be performed in strict compliance with applicable OSHA regulations, NFPA 70E standards, and relevant federal, state, and local requirements. This includes the use of properly licensed personnel, appropriate arc-flash personal protective equipment, site protection measures, thorough cleanup, and responsible disposal of waste materials. The procurement is classified under NAICS Code 238210 (Electrical Contractors and Other Wiring Installation Contractors) and Product Service Code J061, with a Small Business Administration (SBA) set-aside, indicating preference for qualified small business entities. The contracting entity is the USCG Academy, a federal office, and the primary point of contact for this opportunity is Jerome Manuel ([email protected]). Secondary contact is CDR Avery Weston, available at [email protected] or (787) 729-2339. Contractors interested in this opportunity should ensure they possess the necessary licensing, expertise in medium-voltage switchgear systems, and familiarity with ANSI/NETA testing protocols. The project requires strict adherence to safety and regulatory standards, as well as the ability to coordinate effectively with government personnel. Further details, including attachments, can be accessed via the official SAM.gov notice at https://sam.gov/opp/74ff5bb933da4d4ea11b225bd7b96b82/view. This contract represents a critical maintenance activity for the Coast Guard Academy’s electrical infrastructure, with outcomes focused on ensuring reliable, safe, and compliant operation of the main switchgear serving Smith Hall.