Gas Leak Repair, Valve Installation, and Asphalt Patching Services

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

SPECIAL MISSION TRAINING CENTER (SMTC)

Contract Value

Not provided

Codes & Classification
Solicitation Number

75110PR270000104

NAICS

237120 - Oil and Gas Pipeline and Related Structures Construction

Classification Code

Z2NA

Additional Details
Set Aside

SBA

Place of Performance

Birmingham, Alabama, UNITED STATES

SourceSAM
The Special Mission Training Center (SMTC), a federal entity, has issued Solicitation 75110PR270000104 as a Request for Quotation (RFQ) for commercial services related to gas leak repair, valve installation, and associated site restoration at the Coast Guard Training Center Birmingham Southern, located at 900 Arkadelphia Road, Birmingham, Alabama 35204. This procurement is set aside exclusively for small business concerns under the North American Industry Classification System (NAICS) code 237120 (Oil and Gas Pipeline and Related Structures Construction), with a small business size standard of $45.0 million. The applicable Product Service Code is Z2NA. The primary objective of this solicitation is to address a gas leak within the facility’s parking lot, ensuring the safe and compliant repair of the gas line, installation of a new shutoff valve, and full restoration of the affected area. The scope of work is comprehensive, encompassing detection and repair of the gas leak, excavation and spoil removal, installation and testing of a new gas valve, gravel backfill, asphalt patching, and thorough site cleanup and demobilization. The contract will be awarded as a firm-fixed-price agreement, with all work—including final cleanup—required to be completed within ten (10) business days from the date of award. Key requirements and deliverables are organized into four Contract Line Item Numbers (CLINs): - **CLIN 0001: Gas Leak Detection, Excavation, Spoil Removal, and Gravel Backfill** The contractor is responsible for locating the gas leak, saw-cutting and excavating the parking lot (approximately 6 feet by 6 feet, up to 6 feet deep), implementing all necessary safety measures, removing and disposing of excavated materials, and placing and compacting clean gravel or approved backfill after repair and testing. The government will provide utility markings, but the contractor retains responsibility for safe excavation practices. - **CLIN 0002: Gas-Line Repair, Valve Installation, Testing, and Test Record** The contractor must supply all labor, materials, equipment, pipe, fittings, connectors, and one new gas shutoff valve required to repair the identified gas leak. The repaired line and valve must be tested prior to backfill, with a written test record provided to the Government Technical Representative (GTR) and Contracting Officer. Gas service may not be restarted until successful testing and any required utility approvals are obtained. - **CLIN 0003: Asphalt Repair** Following completion of the gas-line repair and backfill, the contractor will prepare the base and install an asphalt patch that matches the existing pavement as closely as possible. The patch must be properly compacted, level with the surrounding surface, and safe for normal parking-lot traffic, with all edges and joints sealed as needed. - **CLIN 0004: Site Cleanup and Demobilization** The contractor is required to remove all debris, spoils, excess materials, equipment, signage, barriers, and temporary items from the work area, leaving the site clean, orderly, and safe for normal use. All work must adhere to the requirements outlined in the attached Statement of Work (SOW) referenced in the solicitation. Contractors are expected to comply with all incorporated provisions and clauses, which are accessible via www.acquisition.gov and are current through Federal Acquisition Circular 2026-01 (effective 03/13/2026). An organized site visit is scheduled for November 5, 2026, at 10:00am CST at the Training Center Birmingham main gate. Interested vendors must submit visitor information—including company name, contact details, visitor name, last four digits of SSN, date and place of birth, and Real ID driver’s license number—via email to the primary contact, John Caicedo ([email protected]), prior to the visit. All visitors must meet Coast Guard facility access requirements; individuals with felony convictions are not permitted. Offerors must submit signed and dated offers by the specified response date of December 11, 2026, at 16:11. Submissions must include the solicitation number, offeror’s contact information, Unique Entity Identifier (UEI), information necessary for evaluation under provision 52.212-2, required representations and certifications, and a statement of agreement with all solicitation terms and conditions. Offers must remain valid for at least 30 calendar days from the date of receipt. This opportunity is ideal for small businesses with expertise in gas utility repair, excavation, site restoration, and related construction services, particularly those familiar with federal contracting requirements and safety protocols. The project’s defined scope, short period of performance, and clear deliverables make it suitable for contractors with the capacity to mobilize quickly and execute specialized repair and restoration work in a secure, regulated environment. For further details, including access to the full solicitation and attachments, interested parties should refer to the official notice on SAM.gov (Opportunity ID: b10c6b4beb5948b1b88c26c511fb2e06) or contact John Caicedo at 206-815-1586 or [email protected].
Documents7