STA Sand Key Repair Fuel Lines and Tank

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

BASE MIAMI BEACH

Contract Value

Not provided

Codes & Classification
Solicitation Number

30321PR270000001

NAICS

237120 - Oil and Gas Pipeline and Related Structures Construction

Classification Code

Z2PZ

Additional Details
Set Aside

SBA

Place of Performance

Clearwater Beach, Florida, UNITED STATES

SourceSAM
Documents2
The United States Coast Guard (USCG), under the Department of Homeland Security, has issued a combined synopsis/solicitation for the repair, remediation, testing, and coating of fuel lines, storage tanks, and associated fuel system infrastructure at USCG Station Sand Key, located at 1375 Gulf Boulevard, Clearwater Beach, Florida. This procurement is being conducted in accordance with Federal Acquisition Regulation (FAR) Subpart 12.6 and Part 13, utilizing simplified acquisition procedures, and is classified under NAICS code 237120 (Oil and Gas Pipeline and Related Structures Construction), with a small business size standard of $45 million. The opportunity is set aside exclusively for small businesses. The primary objective of this contract is to ensure the continued safe and reliable operation of the station’s fuel system, which is critical for supporting Coast Guard vessel operations. The scope of work encompasses a comprehensive suite of tasks, including the repair and remediation of diesel (DSL) and regular unleaded (RUL) fuel lines and tanks, treatment and removal of corrosion on spill containment units, labeling and calibration of tank gauges with high-level alarms, and the application of environmentally safe coatings to all relevant components. The contractor will also be responsible for investigating and repairing fuel dispensers to correct flow rates, conducting integrity tests on under dispenser containment (UDC) units and transition sumps, and ensuring the proper operation of leak detection panels and sensors. Replacement of non-compliant copper fuel piping supplying the emergency generator tank is also required. A critical requirement is the maintenance of operational continuity; the contractor must coordinate closely with station personnel to ensure that fuel availability for operational vessels is not interrupted during the execution of repairs. All work must be scheduled to minimize interference with the station’s normal operations, which run from 0700 to 1700, Monday through Friday, excluding federal holidays. Any work outside these hours requires prior written approval from the Contracting Officer’s Representative (COR). Contractors must adhere to stringent safety and security protocols. Compliance with OSHA Construction Standards (29 CFR Part 1926) is mandatory, and a written site safety plan naming a designated safety supervisor must be submitted prior to commencement of work. All personnel must be U.S. citizens or lawful permanent residents; foreign nationals are strictly prohibited from accessing the site. A roster of all personnel, including subcontractors, with valid government-issued identification, must be provided before or on the Notice to Proceed date. All vehicles, equipment, and packages are subject to search at any time by Coast Guard security. Site-specific regulations include observance of military customs such as morning and evening colors, adherence to a 15 mph speed limit, prohibition of cell phone use while driving or operating equipment, and restriction of smoking to a designated area. Firearms and weapons are strictly forbidden on the premises. The contractor is responsible for the protection of all materials and equipment, as well as for the cleanup and proper disposal of all refuse in accordance with federal, state, and local regulations. The Government intends to award a single Firm-Fixed-Price (FFP) contract to the offeror whose proposal represents the best value, considering technical capability, past performance on similar projects, and price reasonableness. Technical capability will be evaluated based on compliance with all statement of work requirements and the demonstrated ability to maintain fuel availability during the project. Past performance will be assessed based on records of satisfactory completion of comparable commercial or government fuel infrastructure projects. A pre-proposal site visit is scheduled for November 4, 2026, at 10:00 AM EST at the project location. Interested offerors are encouraged to attend to gain a comprehensive understanding of the site conditions and project requirements. The contracting entity for this opportunity is BASE MIAMI BEACH, and the primary point of contact is MKC Zachery Little, who can be reached at [email protected] or (417) 612-3258. The solicitation is active, with responses due by November 13, 2026, at 8:11 PM. All applicable FAR and Homeland Security Acquisition Regulation (HSAR) clauses are incorporated by reference. This opportunity is well-suited for small businesses with demonstrated experience in fuel system infrastructure repair, corrosion remediation, and compliance with federal safety and security standards. Contractors must be prepared to operate within an active military environment, maintain strict adherence to operational and security protocols, and deliver high-quality, compliant work within the specified timeframe.