H259-- ELECTRICAL 5-YEAR ARC FLASH STUDY (VA-27-00002938)

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

252-NETWORK CONTRACT OFFICE 12 (36C252)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C25227Q0050

NAICS

541350 - Building Inspection Services

Classification Code

H259

Additional Details
Set Aside

None

Place of Performance

-

SourceSAM
Documents1
The Department of Veterans Affairs, through its 252-Network Contract Office 12, has issued a Special Notice (Procurement Identifier: 36C25227Q0050) for a comprehensive five-year Arc Flash Hazard Analysis, classified under NAICS Code 541350 (Building Inspection Services). This procurement seeks a qualified contractor to conduct a detailed Arc Flash Hazard Study in accordance with the latest editions of NFPA 70E, NFPA 70, and IEEE Std 1584, ensuring compliance with all relevant electrical safety standards and codes. The primary objective of this engagement is to enhance electrical safety within the facility by systematically analyzing arc flash hazards across the entire electrical distribution system—from the incoming utility equipment down to 208V systems. The scope encompasses all significant electrical locations, including switchboards, switchgear, motor control centers, panelboards, busways, and related components. The contractor will be responsible for field-verifying and updating existing single-line drawings, or developing new ones if necessary, to accurately reflect the facility’s as-built electrical configuration. Key requirements include thorough data gathering and field verification, which necessitates the physical inspection and documentation of each piece of equipment covered by the study. This process involves recording equipment details such as manufacturer, model, ratings, configuration, overcurrent protection, relaying types, fuse information, cable specifications, and motor load data for motors 25 HP and above. Coordination with facility engineering staff is essential to obtain utility data, including minimum and maximum fault currents and X/R ratios, with all correspondence documented in the final report. The contractor will perform a three-phase bolted fault short-circuit study, protective device coordination study, and arc flash hazard analysis. These studies must adhere to ANSI, IEEE, NEMA, and NEC standards, and include calculations, time-current curves, and tabulated device settings. The analysis will identify equipment duty ratings, verify compliance, and highlight any deficiencies or violations. Incident energy and flash protection boundary calculations will be conducted for all significant locations, considering multiple system scenarios to establish worst-case conditions and ensure personnel safety. A critical deliverable is the installation of machine-printed arc flash warning labels on all evaluated electrical devices, compliant with NFPA 70E requirements. The contractor will also address missing or deficient labels and hardware as discovered during fieldwork. Upon completion, an exit briefing will be conducted for facility engineering staff, summarizing study phases, notable hazard areas, recommended mitigation strategies, NEC violations, and other safety concerns. Final submittals will include four bound copies and an electronic version (CD/DVD) of the comprehensive report, containing executive summaries, detailed study descriptions, tabulated device ratings, coordination curves, fault current calculations, incident energy results, recommendations, and one-line diagrams in both AutoCAD and PDF formats. SKM-compatible data import files and a supplemental report documenting equipment conditions and corrective actions are also required. All work must be supervised and approved by a Registered Professional Electrical Engineer (PE) with a minimum of five years’ experience in power systems studies. The project duration is set at 180 days from notice to proceed, with onsite work scheduled during normal operating hours (Monday–Friday, 7:30 AM–4:30 PM). Any work outside these hours or requiring power outages must be coordinated in advance with the Contracting Officer’s Representative (COR). This opportunity is managed by the Department of Veterans Affairs, with primary contact Derrick Paquette ([email protected], 414-844-4800). Contractors interested in this active notice should review the full solicitation and attachments via SAM.gov (Opportunity ID: b864f528787c4677abc236ae17bf44a9) and respond by November 2, 2026, at 14:11. This procurement represents a significant opportunity for firms specializing in electrical safety studies, power system analysis, and compliance with federal and industry standards. The requirements for professional engineering oversight, comprehensive reporting, and strict adherence to safety protocols will remain constant throughout the contract lifecycle.