H312--Fire Alarm and Testing Inspection FY 2027 Services Procurement - 541 Engineering - VAMC CLEVELAND
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
250-NETWORK CONTRACT OFFICE 10 (36C250)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C25027Q0066
NAICS
561621 - Security Systems Services (except Locksmiths)
Classification Code
H312
Additional Details
Documents1
The Department of Veterans Affairs (VA), through its 250-Network Contract Office 10, is conducting market research via a Sources Sought Notice (Procurement Identifier: 36C25027Q0066) to identify qualified contractors capable of providing comprehensive fire alarm testing and inspection services at the Louis Stokes VA Medical Center (VAMC) in Cleveland, Ohio. This notice is not a solicitation and does not constitute a commitment by the Government to issue a solicitation or award a contract. Rather, it is intended to gather information to inform the VA’s acquisition strategy for these critical services.
**Purpose and Scope**
The primary objective of this procurement is to ensure the ongoing safety and regulatory compliance of the Cleveland VAMC’s fire alarm and fire suppression systems. The selected contractor will be responsible for the on-site testing, inspection, and preventative maintenance of government-owned Notifier fire alarm and suppression components. All work must adhere to the latest standards set forth by the National Fire Protection Association (NFPA 72, 2022 edition), Occupational Safety and Health Administration (OSHA), The Joint Commission (TJC), and original equipment manufacturer specifications. The scope of services encompasses annual, semi-annual, quarterly, and specialized testing (including elevator devices and kitchen hoods), as well as the submission of detailed inspection reports and safety plans.
**Key Requirements and Deliverables**
Contractors must provide all labor, materials, equipment, transportation, and supervision necessary to perform the required services. Specific tasks include:
- **Annual Testing:** All devices (except elevator-associated) must be tested in January, with comprehensive reporting.
- **Semi-Annual Testing:** Conducted in July, with similar reporting requirements.
- **Quarterly Testing:** Scheduled for January, April, July, and October.
- **Elevator Device Testing:** Performed in February, coordinated with the elevator contractor and VA electronics shop.
- **Kitchen Hood Testing:** Conducted twice yearly (June and December) after 7pm on weekdays.
- **Live Testing, HVAC Duct Detector Testing, Atrium Smoke Detector Testing, Tamper and Water Flow Testing:** Each with specific scheduling, coordination, and reporting requirements.
Deliverables include a site-specific safety plan, testing schedules for each service type, and detailed test reports (in both PDF and Excel formats) within 14 days of testing completion. Reports must clearly identify any devices or systems that fail and require corrective action, and must be organized by device type and address.
**Contractor Qualifications and Responsibilities**
Prospective contractors must demonstrate at least five years of recent experience (within the last seven years) in testing and maintaining Notifier fire alarm systems of similar size and complexity. Proof of access to Notifier parts, programming capabilities, and technical support is required. Contractors must also provide references and designate a Contract Manager and onsite Project Manager, both of whom must be available for coordination and oversight throughout the contract period.
Prior to bidding, contractors are expected to visit the Cleveland VAMC to assess the condition of the fire alarm systems and facility. The equipment is offered “as-is,” and no claims for pre-existing deficiencies will be entertained post-award. The contract will be a firm-fixed-price service agreement, with the contractor assuming full responsibility for performance costs and outcomes.
**Facility and System Details**
The Louis Stokes VAMC encompasses approximately 2 million square feet across multiple buildings, including the Cares Tower, Main Facility, Atrium, Women’s Health Annex, Learning Exchange, and Parking Garage. The fire alarm system is currently undergoing an upgrade to a new Notifier system, and the contract will cover both legacy and new equipment as it is brought online. Coordination with ongoing upgrade projects will be essential to ensure seamless service delivery.
**Special Considerations**
- Testing may require after-hours or weekend work to minimize disruption to patient care.
- Contractors must supply all necessary tools and equipment, including ladders, scissor lifts, Notifier keys, and access to the CLSS Gateway network.
- VA personnel will assist with access to secure or hard-to-find areas.
- Onsite parking is not available; contractors must secure street parking.
- All work must be performed in accordance with VA security and information protection requirements, including the use of FIPS 140-2 validated encryption for sensitive information.
- Contractors may be subject to basic background investigations.
**Contract Administration and Oversight**
Quarterly meetings between the contractor, Contracting Officer (CO), and Contracting Officer’s Representative (COR) will be held to review performance and address any issues. The COR will utilize a Quality Assurance Surveillance Plan to ensure compliance with all deliverable requirements.
**Contracting Entity and Contact Information**
- **Contracting Office:** 250-NETWORK CONTRACT OFFICE 10 (36C250), Department of Veterans Affairs
- **Place of Performance:** Louis Stokes VA Medical Center, 10701 East Blvd, Cleveland, OH 44106
- **NAICS Code:** 561621 – Security Systems Services (except Locksmiths)
- **PSC:** H312 – Inspection of Fire Control Equipment
- **Small Business Size Standard:** $25,000,000
- **Primary Contact:** Lakeisha Jackson, [email protected], (216) 447-8300 ext. 49622
**Response Instructions**
Interested parties should submit their responses via email to Lakeisha Jackson by 12:00 p.m. EDT on Friday, October 30, 2026. No pricing or offers are requested at this stage; all information is to be provided voluntarily and at no cost to the Government.
**Summary**
This Sources Sought Notice represents an opportunity for experienced fire alarm service providers to support the safety and compliance mission of the Cleveland VAMC. Contractors with proven expertise in Notifier fire alarm systems, robust reporting capabilities, and the ability to coordinate complex testing schedules in a large healthcare environment are encouraged to respond. The information gathered will inform the VA’s acquisition strategy and may lead to a future solicitation for these services.