Elevator Replacement - JBSA-Randolph
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
FA3016 502 CONS CL
Contract Value
Not provided
Codes & Classification
Solicitation Number
FA301627Q7005
NAICS
-
Classification Code
-
Additional Details
The Department of the Air Force, through the 502d Contracting Squadron (502 CONS CL), has issued a Sources Sought Notice (FA301627Q7005) to conduct market research for the modernization and environmental investigation of an elevator at Joint Base San Antonio (JBSA) Randolph, specifically in Building B663, located at 10257 East St W, Randolph AFB, San Antonio, Texas. This notice is intended solely for information and planning purposes and does not constitute a Request for Proposal (RFP) or Invitation for Bid (IFB). The government seeks to identify qualified businesses with the technical expertise, experience, and interest to undertake this specialized project.
**Purpose and Scope**
The primary objective of this procurement is to modernize and replace the existing elevator system in Building B663, ensuring compliance with current safety, accessibility, and environmental standards. The project encompasses two major components: (1) comprehensive elevator modernization using non-proprietary, open-architecture equipment, and (2) environmental investigation and, if necessary, remediation related to the elevator’s hydraulic system.
**Key Requirements and Deliverables**
*Elevator Modernization:*
- Complete replacement of all mechanical, control, and hydraulic components with non-proprietary, open-architecture systems. The new equipment must allow any licensed elevator mechanic to access onboard diagnostics without the need for proprietary software, factory passwords, or specialized tools.
- Installation of a new double-bottom hydraulic jack with a protective PVC liner, a new door operator, electronic safety edges, a microprocessor-based controller, ADA-compliant car operating panels, hall stations, an emergency two-way communication system, and energy-efficient pump unit components.
- All work must be performed by a Texas Licensed Elevator Contractor, ensuring adherence to state licensing requirements.
- The upgraded system must fully comply with the Americans with Disabilities Act (ADA), ASME A17.1-2016/CSA B44-16, and Texas Health & Safety Code Chapter 754 (TAC Ch. 74).
- The contractor is responsible for conducting operational and load testing, and for certifying the elevator upon completion.
*Environmental Investigation and Remediation:*
- Execution of soil borings and collection of samples at various depths around the elevator hydraulic jack to test for hydraulic fluid contamination, following EPA-approved procedures.
- Delivery of a comprehensive laboratory analysis report within 20 days of inspection, including field activities, boring logs, mapping, and leak determination.
- If no contamination is found, preparation of a report to support a Texas Commission on Environmental Quality (TCEQ) “No Further Action” (NFA) letter under the Texas Risk Reduction Program (TRRP - 30 TAC 350).
- If contamination is detected, development of a Remedial Action Plan (RAP) within the 30-day period of performance for submission to TCEQ, Civil Engineering, and Contracting.
- If required, execution of environmental remediation, including excavation, containerization/disposal of hydraulic fluid and contaminated soil, and clean backfill.
**Contracting Entity and Classification**
- Contracting Entity: 502d Contracting Squadron (502 CONS CL), Department of the Air Force, Department of Defense
- Place of Performance: JBSA-Randolph, Building B663, San Antonio, Texas, USA
- Primary NAICS Code: 238290 – Other Building Equipment Contractors (Elevator Installation, Modernization, and Repair)
- Alternative NAICS Code: 236220 – Commercial and Institutional Building Construction
- Product Service Code (PSC): J039 – Maintenance, Repair, and Rebuilding of Equipment: Elevators
**Submission and Contact Information**
Interested firms are required to submit a Capability Statement that addresses their corporate profile, technical experience, and capabilities relevant to the project. This includes confirmation of Texas elevator contractor licensing, recent experience with non-proprietary elevator modernization, environmental investigation and remediation expertise, and experience working on active military installations.
Responses must be submitted electronically via email to the following contacts:
- Primary: Benjamin Windham ([email protected], 210-652-9106)
- Secondary: Kathryn Morkin ([email protected], 210-652-5047)
The subject line should read: “Response to Sources Sought: FA301627Q7005 - B663 Elevator Modernization.” The response deadline is November 5, 2026, at 10:00 AM Central Time.
**Procurement Type and Special Considerations**
This is a market research (Sources Sought) notice; no set-aside is currently specified, and the government is open to responses from all qualified entities. There are no attachments or additional documents provided at this stage. Contractors should note the requirement for Texas elevator contractor licensing and demonstrated experience with both elevator modernization and environmental compliance in accordance with state and federal regulations. Experience working on Department of Defense installations, including familiarity with access control and coordination with base civil engineering, is highly desirable.
**Constant Elements**
The project location, compliance requirements, and the need for non-proprietary, open-architecture elevator systems will remain constant throughout the contract lifecycle. The expectation for environmental due diligence and, if necessary, remediation in accordance with TCEQ and TRRP standards is also a fixed requirement.