J061--SOURCES SOUGHT NOTICE - Triennial Electrical Inspection Testing and Maintenance Services Requirement - Louis A Johnson VA Medical Center 36C24527Q0039

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

245-NETWORK CONTRACT OFFICE 5 (36C245)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24527Q0039

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Classification Code

J061

Additional Details
Set Aside

None

Place of Performance

Clarksburg, West Virginia, UNITED STATES

SourceSAM
Documents1
The Department of Veterans Affairs (VA), through its Veterans Health Administration (VHA) and Network Contracting Office (NCO) 5, has issued a Sources Sought Notice (36C24527Q0039) to identify qualified vendors capable of providing comprehensive triennial electrical system inspection, testing, and maintenance services at the Louis A. Johnson VA Medical Center (LAJ VAMC) in Clarksburg, West Virginia. This procurement is intended to ensure the ongoing safety, reliability, and regulatory compliance of the facility’s electrical infrastructure, supporting the hospital’s mission to deliver uninterrupted, high-quality healthcare services. **Purpose and Scope** The primary objective of this requirement is to achieve and document 100% compliance with all applicable codes and standards for the normal and Essential Electrical System (EES) distribution and support equipment at LAJ VAMC. The scope encompasses visual, mechanical, and electrical testing, preventive maintenance, and minor corrective actions for a wide range of electrical assets, including medium- and low-voltage switchgear, switchboards, panelboards, motor control centers, transformers, busways, feeder cables, automatic transfer switches (ATS), protective relays, grounding systems, uninterruptible power supplies (UPS), and patient care space receptacles. The work is designed to verify system integrity, identify and correct deficiencies, and provide the documentation necessary to satisfy The Joint Commission (TJC), Centers for Medicare & Medicaid Services (CMS), National Fire Protection Association (NFPA), and VA accreditation and inspection requirements. Notably, generator preventive maintenance and load bank testing, arc flash risk assessment and coordination study updates, and campus power quality/harmonics surveys are excluded from this contract and are being procured separately. **Key Requirements and Deliverables** Contractors must provide all labor, supervision, NETA-certified personnel, licensed electricians, professional engineering oversight, calibrated test equipment, materials, transportation, and incidentals necessary to perform the required services. The technical requirements are extensive and include: - Inspection, testing, and cleaning of medium- and low-voltage switchgear, transformers, and associated distribution equipment. - Functional and performance testing of ATSs, including transfer timing and bypass operations. - Protective relay testing and calibration, with settings verified against the current government-furnished coordination study. - Grounding system resistance testing and verification of isolated ground integrity in patient care areas. - Infrared thermographic surveys of all major electrical equipment. - Comprehensive testing of patient care space receptacles for polarity, voltage, grounding, and retention force. - UPS and battery system inspection and testing in accordance with NFPA and IEEE standards. - Documentation reconciliation, including maintenance record review, deficiency reporting, and preparation of a final triennial test report package. - Submittal of a range of deliverables, such as project management plans, safety plans, personnel certifications, calibration certificates, outage schedules, weekly progress reports, field test data, deficiency logs, thermography reports, compliance crosswalks, and project closeout documentation. All work must conform to the latest editions of applicable codes and standards, including but not limited to NFPA 70 (NEC), NFPA 70B, NFPA 70E, NFPA 99, NFPA 101, NFPA 111, ANSI/NETA MTS, VHA Directive 1028, and VA design manuals. **Contractor Qualifications** The prime contractor must be an ANSI/NETA-Accredited Company or hold equivalent third-party accreditation, with a minimum of five years’ continuous experience in comparable electrical testing within occupied healthcare facilities. Demonstrated completion of at least three similar projects at hospitals, VAMCs, or DoD healthcare facilities within the past five years is required. An active ISO 9001:2015 quality management system or equivalent is also mandatory. Key personnel must include a project manager with at least 10 years of relevant experience, a West Virginia-licensed professional engineer, NETA Level IV and III technicians, a WV Master Electrician, a site safety officer, and a certified infrared thermographer. All on-site staff must meet stringent certification, training, and background check requirements, including VA-mandated training and security clearances. **Contract Structure and Performance** The anticipated contract will be a firm-fixed-price (FFP), single-award vehicle, with a period of performance of 180 calendar days from Notice to Proceed (NTP). Mobilization must occur no later than 30 days from award. The work will be structured in phases, including mobilization, field testing, ATS/IRT activities, and final reporting/closeout. De-energized work in clinical areas is generally restricted to weekends, holidays, or after hours to minimize operational impact, and all major shutdowns require advance coordination and approval. **Compliance and Quality Assurance** The contractor is responsible for ensuring all work meets or exceeds the pass/fail criteria of ANSI/NETA MTS and manufacturer specifications. All deficiencies must be documented and addressed per contract terms. A minimum 12-month workmanship warranty is required, and any necessary retesting during the warranty period must be provided at no additional cost. The government will administer a Quality Assurance Surveillance Plan (QASP) to monitor schedule adherence, submittal quality, safety performance, and compliance. **Contracting Entity and Contact Information** - **Contracting Office:** 245-Network Contracting Office 5 (NCO 5), Department of Veterans Affairs - **Place of Performance:** Louis A. Johnson VA Medical Center, 1 Medical Center Drive, Clarksburg, WV 26301 - **NAICS Code:** 238210 (Electrical Contractors and Other Wiring Installation Contractors) - **PSC Code:** J061 (Maintenance, Repair, and Rebuilding of Equipment—Electric Wire and Power Distribution Equipment) - **Primary Contact:** William Pratt, [email protected], 410-642-2411 **Procurement Type and Set-Aside** This is a sources sought notice intended to gauge interest and capability among potential vendors. The final set-aside determination (e.g., SDVOSB) will be made by the Contracting Officer, with Service-Disabled Veteran-Owned Small Business (SDVOSB) priority per VAAR 819.7004. **Response Instructions** Interested firms must submit a detailed capability statement addressing business information, socio-economic status, relevant experience, available contract vehicles, service capabilities, certifications/licenses, and compliance with subcontracting limitations. Responses are due by November 5, 2026, at 10:00 AM ET, and should be sent to [email protected] with the specified subject line. **Summary** This opportunity represents a significant, highly specialized requirement for electrical system inspection, testing, and maintenance at a major VA medical center. Contractors must demonstrate deep technical expertise, robust quality and safety programs, and a proven track record in healthcare environments. The contract’s comprehensive scope, strict compliance requirements, and operational sensitivity make it well-suited for established firms with advanced electrical testing capabilities and experience in complex, mission-critical facilities.