N045--Boiler 3 Oxygen Analyzer and Steam Flow Meter

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

247-NETWORK CONTRACT OFFICE 7 (36C247)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24727Q0050

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Classification Code

N045

Additional Details
Set Aside

SDVOSBC

Place of Performance

Dublin, Georgia, UNITED STATES

SourceSAM
Documents2
The Department of Veterans Affairs, through its 247-Network Contract Office 7, has issued a combined synopsis/solicitation (Procurement Identifier: 36C24727Q0050) for the provision and installation of a new oxygen analyzer and steam flow meter for Boiler #3 at its facility in Dublin, Georgia. This procurement is classified under NAICS code 238220, which pertains to Plumbing, Heating, and Air-Conditioning Contractors, and is set aside exclusively for Service-Disabled Veteran-Owned Small Business Concerns (SDVOSBC). The primary objective of this procurement is to enhance the operational efficiency and control of Boiler #3 by integrating a new oxygen analyzer and steam flow meter. The intended outcome is to ensure precise monitoring and control of combustion parameters, thereby optimizing fuel efficiency, maintaining regulatory compliance, and supporting safe boiler operation. Key requirements and deliverables for this project include the supply and installation of an oxygen analyzer capable of providing active trim control to the burner fuel/air ratio. The analyzer must transmit signals directly to the combustion controls, enabling real-time adjustments for optimal combustion. Additionally, a steam flow meter with a 4-20 mA analog output is required, which will be wired into the local CB Hawk analog terminal block. Both devices must also provide local display functionality where applicable. The existing boiler stack is a double-walled Selkirk Metalbestos Model P.S., with an inner steel wall and an outer galvanized steel wall, measuring 36 inches in diameter. Boiler #3 operates at a typical pressure of 82 psi (design pressure 200 psi) and a temperature of approximately 330 degrees Fahrenheit. Contractors should ensure compatibility of the proposed equipment with these operational parameters and the existing control infrastructure. The place of performance for this contract is Dublin, Georgia. The contracting activity is managed by the 247-Network Contract Office 7, a federal office under the Department of Veterans Affairs. Interested parties should direct all inquiries and submissions to the primary contact, Sheryl Harris, via email at [email protected], as phone communication is not available. This opportunity is currently active, with a response deadline of October 26, 2026, at 15:10. Contractors are encouraged to review all attachments and details provided in the official notice on SAM.gov (Opportunity ID: fd26eac21a2a43e9afa95a8149c0c136) to ensure a comprehensive understanding of the project scope and requirements. This procurement represents a specialized opportunity for qualified SDVOSBs with expertise in boiler instrumentation, controls integration, and HVAC systems. Contractors should assess their capabilities in delivering, installing, and integrating advanced combustion control and steam measurement solutions within a federal healthcare facility environment.