6135--UPS Battery Replacement

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

262-NETWORK CONTRACT OFFICE 22 (36C262)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C26227Q0041

NAICS

335910 - Battery Manufacturing

Classification Code

6135

Additional Details
Set Aside

None

Place of Performance

San Diego, CA

SourceSAM
Documents1
The Department of Veterans Affairs, through its Network Contract Office 22 (NCO 22), has issued a Sources Sought Notice (Procurement Identifier: 36C26227Q0041) to gather information and identify qualified vendors capable of providing a one-time UPS battery replacement service at the VA San Diego Healthcare System, located at 3350 La Jolla Village Drive, San Diego, CA 92161. This request is strictly for market research and planning purposes and does not constitute a solicitation or a commitment to contract. **Purpose and Scope** The primary objective of this procurement is to ensure the continued reliability and operational integrity of the main server Uninterrupted Power Supply (UPS) system at the VA San Diego Medical Center. The UPS, which supports critical information technology infrastructure, is powered by two battery cabinets (30 batteries per cabinet) that provide essential backup power during outages. The batteries currently in use have exceeded the manufacturer’s recommended lifespan of five years, posing a risk to data integrity, equipment safety, and uninterrupted facility operations. The intended outcome is to replace all 60 batteries with new units, thereby restoring the UPS to optimal performance and safeguarding the facility’s IT systems against power disruptions. **Key Requirements and Deliverables** The contractor will be responsible for the following tasks: - Verifying the operational status of the UPS prior to battery replacement. - Transitioning the UPS from Inverter to Maintenance Bypass mode. - Performing Lock Out/Tag Out (LOTO) procedures on the primary feed (Panel EDM) and confirming the absence of power at the UPS. - Removing and replacing all 60 UPS batteries with the specified model (UPS12-545PLP). - Ensuring all battery terminals are connected and torqued according to manufacturer specifications, with proper documentation. - Restoring the UPS from Maintenance Bypass to Inverter mode and clearing all LOTO procedures. - Verifying post-replacement UPS functionality and submitting both a hard copy and electronic copy of the service report. - Disposing of all removed batteries at an approved hazardous waste collection facility. **Salient Characteristics of Required Batteries** - Manufacturer: C&D Technologies - Battery Type: UPS12-545PLP (also referenced as UPS12-540MR) - String Voltage: 360V; Float Voltage: 410V - Batteries per String: 30 (per cabinet) - Total Number of Cells: 180 - Rated Amp Hour: 123 - Watts per Cell: 506 - Baseline Milliohm Value: 2.5; Warning Value: 3.1; Replacement Value: 3.2 - Parent Equipment Manufacturer: Mitsubishi; Model #: UP9833A-A154SU-4; Serial #: 02-GGF3Q1-02 - Annual Torque Specification: 60 In-Lbs **Contracting Entity and Classification** - Contracting Office: 262-NETWORK CONTRACT OFFICE 22 (36C262), Department of Veterans Affairs - Place of Performance: San Diego, CA - NAICS Code: 335910 (Battery Manufacturing), Size Standard: 1,250 employees - Product Service Code: 6135 - Primary Contact: Victor Oliveros ([email protected]) **Procurement Type and Special Considerations** This notice is a Sources Sought/RFI and not a solicitation. The government is seeking information from all business sizes and types, including small businesses, SDVOSBs, VOSBs, HUBZone, WOSB, and large businesses. Respondents are encouraged to provide detailed capability statements addressing their ability to meet the salient characteristics and requirements, as well as feedback on the draft specifications. Additional information requested includes business size status, manufacturer/distributor status, compliance with subcontracting limitations, COTS status, Buy American Act compliance, lead times, product lifespan, support services, FDA clearance (if applicable), leasing options, and federal contract vehicles. **Submission Instructions** Interested parties should submit their responses via email to Victor Oliveros at [email protected] by October 21, 2026, 15:00 Pacific Time. Responses should address all requested information and will be used solely for planning and market research purposes. No telephone responses will be accepted, and submission does not guarantee inclusion in any future solicitation. **Summary** This opportunity is ideal for contractors with expertise in UPS battery replacement, hazardous material disposal, and experience working within federal healthcare environments. The scope is clearly defined, with a focus on restoring critical backup power infrastructure to manufacturer standards. Contractors should carefully review the salient characteristics and ensure their solutions align with the specified requirements and federal procurement regulations.