J061--Sources Sought Emergency Switchgear Repairs 539
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
250-NETWORK CONTRACT OFFICE 10 (36C250)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C25027Q0019
NAICS
811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Classification Code
J061
Additional Details
Documents1
The Cincinnati Veterans Administration Medical Center (VAMC) is seeking information from qualified firms regarding emergency switchgear repairs under the contract title "Repair Emergency Power Phase 2." This Sources Sought notice, issued by the 250-Network Contract Office 10 (36C250) of the Department of Veterans Affairs, is intended solely for acquisition planning and market research; no proposals are being solicited at this time.
Purpose and Scope:
The primary objective of this procurement is to restore full emergency backup generator functionality at the Cincinnati VAMC, specifically within Building #1. Currently, the facility is operating with only one functional generator, which poses a significant risk in the event of a power failure. The scope encompasses comprehensive repairs to both generators and their associated paralleling switchgear, as identified in a diagnostic report by ABB. The contractor will be responsible for testing, repairing, and replacing equipment as necessary to ensure reliable emergency power for the medical center.
Key Requirements and Deliverables:
- Repair and upgrade both generators and paralleling switchgear, including replacement of two damaged MFR13 and reverse power relays with new protective relays.
- Perform programming changes to the new relays to guarantee proper system functionality.
- Modify doors and wiring to accommodate the upgraded relays.
- Update ABB system drawings to reflect the relay replacements.
- Maintain emergency generator availability and security of the generator/switchgear room throughout the project.
- Coordinate all generator work with the VA, with repairs scheduled over two separate weekends (one per generator), including Saturday work.
- Provide and utilize a load bank rated at 125% for testing both generators (each 1500kW, 3 PH, 4W, 480Y/277V).
- Test the paralleling of both generators and verify system operation under load.
- Change generator priority and verify proper online/shed functionality.
- Conduct complete testing of the emergency power system post-repair to ensure intended operation.
- Coordinate with the VA COR for testing and verification of generator control panels, including newly installed panels.
- Provide a one-year warranty covering all materials and labor.
Performance Monitoring and Acceptance:
The Engineering Service Project Section at Cincinnati VAMC will supervise contract performance, with inspections conducted throughout the project. Final acceptance will be determined by the Project COR upon satisfactory installation and operation.
Security and Records Management:
While C&A requirements and a Security Accreditation Package are not applicable, strict adherence to federal records management laws and VA policies is required. Contractors must ensure the safeguarding, proper handling, and timely return of all records and data generated under the contract. All contractor personnel must complete VA-provided records management training, and these requirements must be flowed down to all subcontractors.
Contracting Entity and Contact Information:
- Contracting Office: 250-NETWORK CONTRACT OFFICE 10 (36C250), Department of Veterans Affairs
- Location: Cincinnati VAMC, generator and electrical rooms
- NAICS Code: 811310 (Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance)
- Product Service Code: J061
- Primary Contact: Ronald T. Heidemann ([email protected], 513-559-3708)
- Notice URL: https://sam.gov/opp/e1f940bd648b453989708e48a9d4370a/view
Procurement Type and Special Considerations:
This is a Sources Sought notice, not a solicitation. The VA is gathering information from capable and interested firms to inform future acquisition strategy. Firms are requested to provide their name, socio-economic status, contract vehicle availability, suggestions for alternative NAICS codes, and any questions to the point of contact via email. No set-aside requirements or follow-on work are identified at this stage. There are no conflicts of interest, non-disclosure requirements, or special packaging/shipping instructions.
Period of Performance:
The anticipated period of performance is 90 calendar days, inclusive of equipment and material lead time. The delivery schedule will be determined.
Constant Elements:
Throughout the contract lifecycle, the place of performance will remain the Cincinnati VAMC, and the scope will consistently focus on restoring and verifying emergency power system functionality. Compliance with VA specifications, records management, and warranty requirements will be maintained.
This opportunity is well-suited for contractors with expertise in commercial and industrial generator and switchgear repair, particularly those familiar with ABB systems and VA facility requirements. Interested firms should review the detailed scope and requirements to assess alignment with their capabilities and respond accordingly for consideration in future procurement actions.