H912--Sources Sought Fire Damper Testing POP 12/31/2026-12/30/2027

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

256-NETWORK CONTRACT OFFICE 16 (36C256)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C25626Q1365

NAICS

541350 - Building Inspection Services

Classification Code

-

Additional Details
Set Aside

None

Place of Performance

BILOXI, MS

SourceSAM
Documents1
This Sources Sought notice, issued under procurement identifier 36C25626Q1365, seeks qualified contractors to perform comprehensive fire damper inspection and testing services at the Biloxi VA Medical Center (VAMC) Campus in Biloxi, Mississippi. The procurement is managed by the 256-Network Contract Office 16 (NCO 16) of the Department of Veterans Affairs, with Jacqueline Ambala as the primary point of contact ([email protected], 757-251-4054). **Purpose and Scope:** The primary objective of this one-time service is to ensure the regulatory compliance, operational integrity, and safety of 247 fire dampers located across both patient and non-patient buildings on the Biloxi VAMC Campus. The work is to be completed within 90 days following the Notice to Proceed, with the overall period of performance spanning from December 31, 2026, to December 30, 2027. The fire dampers are critical components of the facility’s fire prevention infrastructure, interfacing with the existing fire alarm system to prevent the spread of fire and smoke through building ductwork and walls. **Key Requirements and Deliverables:** Contractors are expected to provide all necessary labor, tools, and equipment to inspect, test, and document the condition of each fire damper. The scope of work includes: - Locating and verifying the position of each damper and access panel, updating facility drawings in accordance with NFPA guidelines. - Physically inspecting each damper, including removal and replacement of painted or damaged fusible links with appropriately rated components. - Labeling each damper with a unique identifier, inspection date, condition, and inspector information. - Providing photographic documentation (minimum two photos per damper) and comprehensive inspection reports for each building. - Testing damper operation, including manual activation of actuators, lubrication of moving parts, and verification of closure mechanisms. - Cleaning all work areas using HEPA filtration systems and ensuring no debris impedes damper operation. - Documenting all findings, including pass/fail status, deficiencies, and recommendations for repairs. - Furnishing red-lined AutoCAD 2000/Adobe PDF drawings and organized photographic records on CD, as well as formal inspection reports signed by the inspector. - Coordinating with the Contracting Officer’s Representative (COR), facility maintenance staff, and local fire department to ensure proper notification and system status during testing. Repairs are limited to adjustments and replacement of fusible links and minor components; any additional repairs must be documented with a cost estimate and receive prior written approval from the Contracting Officer. **Applicable Standards:** All work must comply with current National Fire Protection Association (NFPA) codes, The Joint Commission standards, and Occupational Safety and Health Administration (OSHA) regulations. Specific NFPA standards referenced include NFPA 80, 90A, 101, 105, and 5000, with testing aligned to the four-year frequency requirements for fire/smoke dampers. **Location and Classification:** The place of performance is the Biloxi VA Medical Center, 400 Veterans Ave, Biloxi, MS 39531. The applicable NAICS code is 541350 (Building Inspection Services), indicating the requirement for specialized expertise in building safety and regulatory compliance. **Procurement Type and Considerations:** This notice is a Sources Sought, intended to identify capable and interested vendors for potential future solicitation. No set-aside requirements or special considerations are specified in the notice. Contractors should demonstrate experience with large-scale fire damper inspection projects, familiarity with VA and NFPA standards, and the ability to deliver thorough documentation and reporting. **Constant Elements:** Throughout the contract lifecycle, the core requirements—comprehensive inspection, testing, documentation, and compliance with all applicable codes—will remain unchanged. The focus on safety, regulatory adherence, and detailed reporting is central to the project’s success. Interested parties are encouraged to review the full notice and respond by the stated deadline of October 6, 2026, at 16:10. Additional details and the official notice can be accessed via the SAM.gov opportunity listing (https://sam.gov/opp/c241dc02517e4f109bc3c8ef29ca4cf6/view).