J012--Fire Alarm & Fire Protection System Maintenance
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
241-NETWORK CONTRACT OFFICE 01 (36C241)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C24126Q0831
NAICS
561621 - Security Systems Services (except Locksmiths)
Classification Code
J012
Additional Details
Documents1
The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1), has issued a Sources Sought Notice (Procurement Identifier: 36C24126Q0831) to conduct market research for the provision of comprehensive Fire Alarm and Fire Protection System Maintenance services at the Providence VA Medical Center (VAMC) and its associated facilities. This notice is not a solicitation for quotes or proposals, nor will a contract be awarded based on responses; rather, it is intended to identify qualified vendors and inform future acquisition planning.
**Purpose and Scope**
The primary objective of this procurement is to ensure the continuous, reliable operation and compliance of all fire alarm, fire hydrant, fire pump, fire suppression, and sprinkler system components across the Providence VAMC campus (830 Chalkstone Avenue and 20 Regent Avenue, Providence, RI 02908-4799) and the CBOC New Bedford facility (175 Elm Street, New Bedford, MA 02740-6006). The scope encompasses full-service maintenance, installation, modification, repair, quarterly inspection, and testing of these systems, adhering strictly to current National Fire Protection Association (NFPA) codes and relevant healthcare and life safety standards.
**Key Requirements and Deliverables**
- **Fire Alarm Systems:** Maintenance personnel must be factory-trained, qualified, and certified Notifier/ONYX Works fire alarm technicians with at least five years of experience. Technicians must be certified to operate and test Notifier NFS2-3030/NFS2-640 Fire Alarm Control Panels, ONYX Works First Vision Graphics Display, and Digital Voice Command (DVC) systems. Similar qualifications are required for servicing the Simplex 4100U fire alarm control panel at the New Bedford facility. All personnel must hold current licenses for the State of Rhode Island and undergo background investigations due to access to sensitive areas.
- **Fire Hydrants and Pumps:** Annual inspection and flow testing of 13 fire hydrants and main fire pumps are required, typically scheduled on Saturdays to minimize disruption. Documentation of test results must be provided to the VA.
- **Fire Suppression Systems:** Maintenance personnel must have at least five years of experience with systems such as Kidde Fenwal and Pyro Chem, and hold appropriate state licenses. Semi-annual inspections and maintenance are required, with specific scheduling considerations for kitchen and hazardous waste areas to avoid operational disruption.
- **Sprinkler Systems:** Qualified, licensed electricians or fire alarm/sprinkler technicians must perform quarterly preventive maintenance, including inspection and testing of all system components. Personnel must have at least two years of relevant experience and provide evidence of qualifications and prior work.
- **System Components:** The contract covers all components—cabling, control panels, detectors, enunciators, sensors, wiring, etc.—regardless of location, installation date, or brand. Maintenance must follow manufacturer specifications and NFPA 25, 72, and 101, as well as VA and Joint Commission standards. OEM manuals and schematics must be available onsite.
- **Reporting and Documentation:** Contractors must submit quarterly, semi-annual, and annual test reports in NFPA and Joint Commission formats within 14 days of completion. All system data must be backed up and maintained by the contractor.
- **Response and Coverage:** The contract requires 24/7/365 coverage, with a guaranteed uptime of 95%. Emergency service calls must be responded to within one hour by phone and two hours onsite. The contractor’s place of business must be within 40 miles of the Providence VAMC.
- **Compliance and Coordination:** All shutdowns and maintenance activities must be coordinated with the VA COTR, Engineering, Operators, Providence Fire Department, and VA Police, with at least 48 hours’ notice. Contractors must sign in/out, wear badges, and provide detailed field service reports after each visit.
**Contracting Entity and Classification**
- **Contracting Office:** 241-Network Contract Office 01 (36C241), Department of Veterans Affairs
- **NAICS Code:** 561621 – Security Systems Services (except Locksmiths), size standard $25.0M
- **Product Service Code:** J012
- **Place of Performance:** United States (Providence, RI and New Bedford, MA)
- **Primary Contact:** Rosangela Pereira ([email protected], 401-273-7100)
**Procurement Type and Special Considerations**
This is a Sources Sought Notice for market research purposes. Based on responses, the requirement may be set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), Veteran-Owned Small Businesses (VOSB), small businesses, or procured through full and open competition. Interested vendors must complete the attached worksheet and submit a capability statement (maximum 8 pages) electronically in Word or PDF format by September 22, 2026, at 3:00 PM EST. No telephone inquiries will be accepted.
**Constant Elements Over Contract Lifecycle**
Throughout the contract, the following elements will remain constant:
- Adherence to NFPA, VA, and Joint Commission standards
- Full-service maintenance and emergency response requirements
- Comprehensive coverage of all fire protection system components
- Rigorous qualification and licensing requirements for personnel
- Detailed reporting and compliance procedures
- Coordination with VA and local authorities for all shutdowns and maintenance activities
**Summary for Contractors**
Contractors considering this opportunity should possess extensive experience and certifications in fire alarm, suppression, and sprinkler systems, particularly with Notifier, ONYX Works, Simplex, Kidde Fenwal, and Pyro Chem systems. The ability to provide 24/7 coverage, rapid emergency response, and thorough documentation is essential. All work must be performed by licensed professionals, with strict adherence to regulatory standards and VA protocols. The contract offers a one-year base term with four option years, ensuring long-term engagement for qualified vendors.
For further details and to access the full notice, visit [SAM.gov Opportunity ID 433eeef279cc4c168dbb2cf93a38526c](https://sam.gov/opp/433eeef279cc4c168dbb2cf93a38526c/view).