Laminar Flow Animal Cage Changing Stations

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

NATIONAL INSTITUTES OF HEALTH NHLBI

Contract Value

Not provided

Codes & Classification
Solicitation Number

PCA-ORS-09466

NAICS

339112 - Surgical and Medical Instrument Manufacturing

Classification Code

6640

Additional Details
Set Aside

None

Place of Performance

Maryland, UNITED STATES

SourceSAM
The National Institutes of Health (NIH), Office of Research Services (ORS), Division of Veterinary Resources (DVR), has issued a combined synopsis/solicitation (RFQ PCA-ORS-09466) for the procurement of laminar flow animal cage changing stations. This requirement is intended to support rodent husbandry operations at the NIH’s Bethesda, Maryland campus, specifically within Building 10A. The procurement seeks to enhance the safety, efficiency, and ergonomic standards of animal care environments by acquiring advanced cage changing workstations that provide high-level particulate containment and operator protection. Scope and Purpose: The NIH DVR requires a total of thirteen (13) laminar flow animal cage changing stations, divided into two configurations: seven (7) units of 48-inch (120 cm) width and six (6) units of 60-inch (150 cm) width. These stations are critical for maintaining sterile conditions and protecting both laboratory animals and personnel from airborne contaminants and allergens during cage changing procedures. The procurement is structured as a brand-name-or-equal requirement, referencing the Tecniplast ARIA CS48 and CS60 models as benchmarks for capability and configuration. However, any product that meets or exceeds the specified salient characteristics will be considered. Key Requirements and Deliverables: All proposed units must be laminar-flow, ISO Class 3 (per ISO 14644-1) cage changing workstations, featuring robust two-stage filtration systems. This includes both incoming and outgoing air filtered through a particulate pre-filter (minimum ISO Coarse ≥ 60–70% per ISO 16890 / G4 per EN 779) and an H14 HEPA filter, with each HEPA filter individually integrity/DOP scan tested. The workstations must maintain an average laminar air flow velocity of at least 0.30 m/s across the internal chamber, with no measurement point (minimum 8 points) outside the 0.25–0.50 m/s range. Barrier airflow must be sufficient to protect operators from allergens and particulates, with a nominal barrier flow rate of at least 1300 m³/h, verified by smoke test. Additional required features include: - TFT touch-screen control panel (minimum 4.3”) at operator eye level, displaying key operational metrics. - Audible and visual alarms compliant with EN 12469 for out-of-range conditions, filter clogging, and blower faults. - EC motor blowers for energy efficiency and reduced noise/vibration. - Microprocessor-driven, automatically compensating electronic airflow control. - Dual-configuration work surface (flat or recessed) suitable for both mouse and rat cages. - TRESPA® or equivalent autoclavable, scratch-resistant, sound-absorbent work surface. - LED light bar with electronic dimmer for light-sensitive strains. - Electrically height-adjustable, mobile support stand (castered, nominal 125 mm/5”). - Two external, drip-proof power sockets. - Cleanability features such as removable trays, protective nets, and high chemical resistance. - Ergonomic enhancements including a transparent hinged viewing screen, knee-rest panel, and maneuvering bar. Specific dimensional and weight requirements are outlined for each configuration: - 48-inch class: Surface width 120 cm, overall dimensions approx. 1414 × 790 × 1954–2278 mm, weight ≤ 185 kg. - 60-inch class: Surface width 150 cm, overall dimensions approx. 1590 × 790 × 1954–2278 mm, weight ≤ 196 kg. Each unit must be delivered with comprehensive factory test documentation, including noise and light intensity tests, electrical safety, HEPA integrity, alarm functionality, and airflow testing. Units must be CE-compliant and certified by UL/CSA or an equivalent NRTL for electrical safety. The manufacturer must hold ISO 9001 and ISO 14001 certifications. Contracting and Submission Details: This solicitation is issued as a Request for Quotation (RFQ) under FAR Subpart 12.6 for commercial products and services. The acquisition is full and open, with no set-aside restrictions. The applicable NAICS code is 339112 (Surgical and Medical Instrument Manufacturing), and the Product Service Code is 6640. Quotations must include: 1. Completed pricing for both CLINs, including freight (F.O.B. Destination). 2. Product literature/specifications demonstrating compliance with all salient characteristics. 3. Quoted delivery lead time after receipt of order (reference lead time is 12–14 weeks ARO). 4. Current SAM registration. Award will be made on a lowest-priced technically acceptable (LPTA) basis, with technical acceptability determined by compliance with all salient characteristics. Price evaluation will consider the total of both CLINs, including freight. Delivery is to NIH Building 10A, Bethesda, MD 20892, with specific receiving details to be provided at award. The contractor must coordinate delivery at least two weeks in advance. All questions must be submitted in writing by September 15, 2026, 2:00 PM ET. Quotations are due by September 18, 2026, 2:00 PM ET, and should be submitted via email to Travis Brown, Contract Specialist, at [email protected]. The primary point of contact for this procurement is R. Travis Brown, reachable at 301-402-4586. This opportunity is well-suited for manufacturers and suppliers of advanced laboratory containment equipment who can demonstrate compliance with stringent technical, safety, and quality standards, and who have experience delivering to federal biomedical research facilities.