Robotic Arm
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
FDA OFFICE OF ACQ GRANT SVCS
Contract Value
Not provided
Codes & Classification
Solicitation Number
FDA_RFQ_CDRH_2026_133635
NAICS
333998 - All Other Miscellaneous General Purpose Machinery Manufacturing
Classification Code
3695
Additional Details
Documents3
The Food and Drug Administration (FDA), under the Department of Health and Human Services, has issued a combined synopsis/solicitation for the procurement of a collaborative robotic arm system. This acquisition is intended to advance the regulatory science tools development within the Interventional, Radiological Imaging and Visualization regulatory science research program, specifically supporting the Office of Science and Engineering Laboratories (OSEL). The primary objective is to enhance the FDA’s capabilities in developing measurement methodologies for technical performance evaluation, particularly for head mounted displays (HMDs) and image registration in interventional medical procedures.
The robotic arm will serve as a critical instrument for precisely controlling the position and orientation of surgical tools, enabling quantitative characterization of spatial and temporal stability and accuracy in image registration. Additionally, the system will facilitate controlled movement of augmented and virtual reality HMDs or camera systems, allowing for comprehensive evaluation of registration performance as visualized through these devices, including the simulation of user movement. This capability is essential as such technologies are increasingly integrated into medical devices regulated by the FDA’s Office of Product Evaluation and Quality (OPEQ).
The scope of the procurement encompasses the delivery of a complete robotic arm system, including all necessary accessories and software, to be integrated into an existing bench setup. The system must be compatible with custom-developed software for controlling collaborative robotic arms and align with FDA-recognized standards, such as those established by the International Electrotechnical Commission (IEC) for HMDs. The robotic arm’s range of motion and flexibility will enable the development of regulatory science tools for a broader array of device types, accommodating more complex motions than traditional linear translation stages.
Key requirements and deliverables for this procurement include:
1. **Collaborative Robotic Arm**:
- Six rotating joints (degrees of freedom)
- Payload capacity between 5-10 kg
- Reach of 750-950 mm
- Tool Center Point (TCP) movement supporting both z-axis and x-axis locations (100-200 mm from face-plate)
- Minimum TCP movement range: 150 mm in X, Y, and Z axes; yaw and pitch angles of at least ±45°, roll angle of at least ±20°
- Maximum speed per joint: at least 180°/s; maximum TCP velocity: at least 0.5 m/s
- Each joint must have a minimum rotation angle exceeding 220°
- Position detection via encoders; integrated brake mechanism for safety
- Repeatability of less than 0.035 mm; total weight under 30 kg
- Protection rating of IP40 or higher; standard and optional mounting configurations
- Minimum cable length of 2 meters; footprint less than 175 mm x 175 mm
2. **Controller**:
- Power supply: 120V 50-60Hz AC preferred, 220V acceptable
- Maximum dimensions: 500 mm x 500 mm x 500 mm
- I/O ports: minimum 8 digital input, 8 digital output, 2 analog input
- At least 2 USB ports (2.0 or 3.0), 1 Ethernet port, and 1 display port
3. **Teach Pendant (Control Box)**:
- Manual movement and reorientation of the robotic arm
- GUI-based programming via a touch screen (8 inches or larger)
- Emergency stop switch/button
- Connectivity via wireless or cable (minimum 2 meters); weight under 3.5 kg
4. **Software**:
- TCP calibration procedure
- Permanent software license
- Support for third-party software integration (LabVIEW, MATLAB, Visual Basic, C++, C#, Python), including SDKs, APIs, drivers, or ActiveX support
- Compatibility with Windows 10, Windows 11, or Linux operating systems
All deliverables must be provided within 60 days of contract award, packaged and marked per government specifications, and delivered in new, usable, and acceptable condition. The period of performance is 12 consecutive months from the date of award.
The place of delivery and performance is:
US FDA CDRH DIDSR
Attention: Ryan Beams
10903 New Hampshire Avenue, WO62 RM 3126
Silver Spring, Maryland 20993
Phone: 240-402-3216
Fax: 301-796-9925
Email: [email protected]
This procurement is classified under NAICS code 333998 (All Other Miscellaneous General Purpose Machinery Manufacturing) and Product Service Code 3695. There are no set-aside restrictions; the opportunity is open to all qualified vendors.
Interested contractors should note that this is a commercial item acquisition conducted under FAR Part 12. Quotes must be submitted via email to Brandon Rafus ([email protected]) by September 11, 2025, at 4:00 P.M. Eastern Standard Time. The solicitation and all relevant documents are available through the official SAM.gov posting.
This opportunity is managed by the FDA Office of Acquisition and Grant Services, and all inquiries should be directed to the primary contact, Brandon Rafus. Contractors are encouraged to review the attached Statement of Work and ancillary documents for comprehensive technical and contractual requirements.
For further details and to access the solicitation, visit: https://sam.gov/opp/1b24628b21754101a63e6e88e90f58e8/view