Galveston HVAC Repair/Replacement
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
DEPT OF COMMERCE NOAA
Contract Value
Not provided
Codes & Classification
Solicitation Number
1333MF26Q0110
NAICS
238220 - Plumbing, Heating, and Air-Conditioning Contractors
Classification Code
J041
Additional Details
Documents3
The Galveston HVAC Repair/Replacement procurement, originally issued under Solicitation No. 1333MF26Q0110 by the Department of Commerce’s National Oceanic and Atmospheric Administration (NOAA), was intended to address critical HVAC system repairs and replacements at NOAA’s Galveston facility in Texas. Although the solicitation has been officially cancelled via Amendment 0002 and will be recompeted in Fiscal Year 2027, the details provided offer valuable insight into the scope and requirements that will likely remain constant in future iterations.
Purpose and Scope:
The primary objective of this procurement was to replace and repair five HVAC systems across three key areas within the Galveston facility: the Turtle Hospital, Wet Lab Observers Area, and Turtle Barn Aquaculture Area. The project aimed to ensure reliable climate control for animal care and research operations, with a focus on both heating and cooling capabilities. The work included installation of new systems, preventive maintenance, and compliance with coastal corrosion protection standards due to the facility’s proximity to the ocean.
Key Requirements and Expected Deliverables:
- **Equipment Configuration:** The final equipment list, as clarified in the solicitation amendments, included:
- Turtle Hospital: Three ductless mini-split systems (two at 2.5-ton nominal capacity, one at 2-ton).
- Wet Lab Observers Area: One 3-ton conventional split system utilizing existing ductwork (with coil replacement).
- Turtle Barn Aquaculture Area: One new 2-ton ductless mini-split system with two 1-ton indoor heads, each serving a separate room.
- **Dual Use:** All systems were required to provide both heating and cooling.
- **Coastal Corrosion Protection:** Both indoor and outdoor units must feature manufacturer-approved marine-grade corrosion protection suitable for Galveston’s salt-air environment, without voiding warranties.
- **Electrical Work:** Contractors were responsible for providing new electrical disconnects, circuit protection, wiring, conduit, and associated components. Existing branch circuits could be reused if adequate, except for the Turtle Barn installation, where NOAA would provide a new 208V breaker and connection.
- **Installation Materials:** New refrigerant line sets with UV-resistant insulation and new galvanized or stainless steel brackets/supports were required; reuse of existing lines, brackets, or pads was prohibited.
- **Preventive Maintenance:** The contract included a base year for installation and repairs, followed by four option years for quarterly preventive maintenance, resulting in a potential five-year contract period. Preventive maintenance was to be priced as a fixed annual amount, with invoicing in arrears after each quarterly visit.
- **Disposal:** Contractors were to recover refrigerant per EPA regulations, remove old equipment, and turn it over to NOAA for disposal. All other construction debris and excess materials were to be legally disposed of off-site by the contractor.
- **Working Hours:** Standard working hours were 8am–5pm Central Time, Monday through Friday, excluding federal holidays. Work outside these hours required prior written approval, especially in animal care areas.
Contracting Entity and Location:
The procurement was managed by the Department of Commerce, NOAA, with the place of performance at the Galveston facility in Galveston, Texas (TX), United States. The primary point of contact was Suzanne Johnston ([email protected]).
Classification and Procurement Details:
- **NAICS Code:** 238220 (Plumbing, Heating, and Air-Conditioning Contractors)
- **Product Service Code:** J041
- **Set-Aside:** SBA (Small Business Administration)
- **Procurement Type:** Combined Synopsis/Solicitation
- **Inspection and Acceptance:** Final inspection and acceptance were to occur at the Galveston facility.
Special Considerations:
- The solicitation emphasized the importance of site visits for accurate measurements and assessment of field conditions.
- Technical alternatives were permitted if they met the corrected requirements outlined in the amendments, but any deviations had to be clearly identified as exceptions in the technical proposal.
- The contract was tax-exempt as per federal regulations, but NOAA would not issue tax-exempt purchasing documentation for materials.
Constant Elements for Future Opportunities:
Contractors considering future recompetes should expect similar requirements regarding equipment configuration, coastal corrosion protection, preventive maintenance structure, electrical and installation standards, and working hour restrictions. The focus on animal care and research operations, as well as the need for robust, corrosion-resistant HVAC solutions, will remain central to the project’s objectives.
For further information or to monitor future opportunities, contractors may refer to the original solicitation page on SAM.gov (https://sam.gov/opp/5f88a5416f76419ea48028f93f444daf/view) and contact Suzanne Johnston at NOAA.
In summary, this procurement sought qualified contractors capable of delivering turnkey HVAC solutions tailored to the demanding coastal environment and operational needs of NOAA’s Galveston facility, with a strong emphasis on reliability, preventive maintenance, and compliance with federal and environmental standards.