Buckley SFB - BDOC Chiller Replacement

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

FA2543 460 CONS

Contract Value

Not provided

Codes & Classification
Solicitation Number

FA254326Q0027

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Classification Code

N041

Additional Details
Set Aside

SBA

Place of Performance

Aurora, Colorado, UNITED STATES

SourceSAM
The Department of the Air Force, through the 460th Contracting Squadron (460 CONS), has issued a combined synopsis/solicitation for the replacement of the existing chilled water system and two computer room air handlers (CRAHs) at Buckley Space Force Base (SFB) in Aurora, Colorado. This procurement, identified under FA254326Q0027, is classified under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors) and Product Service Code N041, and is set aside for SBA-eligible contractors. The primary objective of this project is to furnish and install two (2) MTA TAEevoTECH 121 air-cooled scroll chillers, each equipped with an integrated pump, on-board buffer tank with immersed evaporator, closed expansion tank, and a factory-installed modularity kit. All equipment must comply with the performance, construction, and accessory requirements specified in the MTA Guide Specifications and Product Literature, as referenced in the updated Statement of Work (SOW). The replacement system is intended to ensure reliable, efficient cooling for critical base operations, in accordance with Air Force Civil Engineering installation standardization guidance. Key deliverables include the complete removal of the existing chilled water system and CRAHs, and the installation and commissioning of the new chiller system. The contractor is responsible for ensuring all work meets the technical specifications and standards outlined in the solicitation documents and attachments. Compliance with all applicable codes, safety regulations, and Air Force requirements is mandatory. A formal site visit is scheduled for Tuesday, 1 September 2026 at 1330 MDT at Buckley SFB. Prospective offerors are strongly encouraged to attend to assess site conditions and clarify any project-specific requirements. Attendance is limited to three representatives per company, and advance notification to the Contracting Officer and Contract Specialist is required by 1000 MDT on 31 August 2026. This will be the only site visit for this solicitation. Questions arising from the site visit must be submitted to both the Contracting Officer and Contract Specialist by 1000 MDT on 3 September 2026. The final deadline for quote submissions, as extended by Amendment 4, is 28 September 2026 at 1600 MDT. Offerors who submitted quotes prior to the latest amendment are required to resubmit their final proposals to ensure compliance with the updated requirements. The contracting activity is the 460 CONS, operating under the Department of the Air Force, with the place of performance at Buckley SFB, Aurora, Colorado. The primary point of contact for this solicitation is Maurice Epps ([email protected]), with TSgt Matt Kennedy ([email protected]) as the secondary contact. This opportunity is particularly suited for contractors with demonstrated experience in the installation and commissioning of large-scale HVAC and chilled water systems, especially within secure or mission-critical environments. Contractors must be SBA-eligible and capable of meeting all technical, administrative, and security requirements as outlined in the solicitation and its amendments. Interested parties are encouraged to review all solicitation documents and amendments available on SAM.gov (Opportunity ID: 0fb79f0f98244b0583ec195081ad6639) and to ensure timely and compliant submission of all required materials.
Documents10