Replace Substation Alpha Relay B11912 Amendment 0002

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

FA4661 7 CONS CD

Contract Value

Not provided

Codes & Classification
Solicitation Number

FA466126R0010

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Classification Code

J039

Additional Details
Set Aside

SBA

Place of Performance

Dyess AFB, Texas, UNITED STATES

SourceSAM
The Department of the Air Force, through the 7th Contracting Squadron (7 CONS CD) at Dyess Air Force Base (AFB), Texas, has issued a solicitation (Procurement Identifier: FA466126R0010) for the replacement of Substation Alpha Feeder Protection Relays at Building 11912. This procurement, classified under NAICS code 811310 (Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance), is set aside for Small Business Administration (SBA) eligible contractors. The primary objective of this project is to ensure the reliable and compliant replacement of two feeder protection relays within Substation Alpha. The scope of work requires the contractor to install two new Government-furnished GE 850 Feeder Protection Relays, replacing the existing GE 760 relays. Installation and wiring must adhere to current National Electrical Code (NEC) and National Electrical Testing Association (NETA) standards, ensuring both safety and operational integrity. A critical component of the contract involves programming the new relays to replicate the settings of the previous units, utilizing configuration data provided by the Dyess AFB Electrical Shop. The contractor is responsible for initial functionality testing without load, followed by coordination with the Electrical Shop prior to energizing the system for further testing and commissioning. Final commissioning and full base load testing must be conducted in the presence of representatives from the Electrical Shop, Contracting, and R&O (Repair & Overhaul) to verify proper installation and operation. Any required power outages for acceptance testing must be coordinated in advance with the Electrical Shop to minimize operational disruptions. This solicitation amendment (Amendment 0002) includes the attachment of several key documents addressing contractor questions from the mandatory site visit, as well as technical references such as the Dyess AFB Electrical Study, relay settings, and feeder relay diagrams. All other terms and conditions of the original solicitation remain unchanged. The place of performance is Dyess AFB, Texas. The contracting office is the 7 CONS CD, a federal entity under the Department of Defense. Interested contractors should direct inquiries to the primary point of contact, Robert Albrightson ([email protected], 325-396-3864), or the secondary contact, Jesse T. Wisowaty ([email protected], 325-696-6043). This opportunity is currently active, with a response deadline of September 18, 2026, at 17:09. Contractors are encouraged to review all attached documents for detailed technical requirements and to ensure alignment with their capabilities in electrical relay installation, programming, and commissioning within a secure federal facility environment. For further details and to access solicitation documents, visit the official notice at: https://sam.gov/opp/4f509db3132e4b52b27d0744dd60ca39/view.
Documents10