6515--SURGICAL EQUIPMENT 36C25526Q0629 ROLLA CBOC
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
255-NETWORK CONTRACT OFFICE 15 (36C255)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C25526Q0629
NAICS
339112 - Surgical and Medical Instrument Manufacturing
Classification Code
6515
Additional Details
Documents1
The Department of Veterans Affairs, through its 255-Network Contract Office 15, has issued a solicitation (Procurement Identifier: 36C25526Q0629) for the supply and installation of advanced surgical equipment at the Harry S Truman VA Medical Center - Multi-Specialty Community-Based Outpatient Clinic (CBOC) in Rolla, Missouri. This procurement is specifically set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC), under NAICS code 339112 (Surgical and Medical Instrument Manufacturing), with Product Service Code 6515.
**Purpose and Scope**
The primary objective of this procurement is to outfit the new Rolla Multi-Specialty CBOC with state-of-the-art electrosurgical units and surgical smoke evacuation systems. These systems are essential for supporting a wide range of surgical procedures and ensuring a safe, compliant, and efficient operating environment for both patients and clinical staff. The contract encompasses the supply, delivery, white glove installation, and performance verification of the specified equipment, as well as comprehensive warranty and support services.
**Key Requirements and Deliverables**
Contractors are required to provide the following equipment and services:
- **Electrosurgical Unit (M3175):** A dual-output, microprocessor-controlled generator capable of delivering both monopolar and bipolar energy, supporting advanced vessel sealing for vessels up to 7 mm, and featuring automatic tissue sensing technology. The unit must be suitable for both open and laparoscopic procedures, comply with all relevant FDA and UL safety standards, and offer multiple energy modalities and waveform options. The system must include a digital user interface, programmable presets, real-time status display, and robust safety features such as return electrode monitoring and automatic fault detection. Compatibility with standard surgical instruments and accessories is required, and the package must include all necessary cables, adapters, footswitches, and both reusable and disposable handpieces, as well as a mobile cart.
- **Surgical Smoke Evacuation System (M8523):** A portable, high-efficiency unit designed to capture and filter surgical smoke generated during electrosurgical and laser procedures. The system must provide a minimum flow rate of 25-35 CFM, utilize a multi-stage filtration system (including ULPA/HEPA and activated carbon filters), and offer adjustable suction levels, automatic and manual activation, filter life monitoring, and low-noise operation (≤60 dBA). The unit should be compact, mobile, compatible with standard tubing and accessories, and operate on standard U.S. electrical power.
- **White Glove Delivery and Installation:** Delivery is FOB Destination, initially to an offsite warehouse (location to be determined), with subsequent installation at the Rolla CBOC (13063 Old Wire Rd, Rolla, MO 65401-000). The contractor is responsible for coordinating delivery and installation with the VA Activation team, adhering to the construction schedule, and ensuring all work is performed with minimal disruption to ongoing operations and in compliance with all safety requirements.
- **Documentation and Inventory:** Vendors must provide detailed packing slips with line-by-line inventory, including descriptions and serial numbers for each item, to facilitate property book entry upon receipt.
- **Warranty and Support:** A manufacturer’s two-year, free replacement warranty is required for all units, covering normal wear and tear and including free return shipping.
**Contract Administration and Performance**
The period of performance is from November 2, 2026, to January 31, 2027, allowing for delivery and installation in alignment with the facility’s construction and activation timeline. The contractor is responsible for the installation, performance verification, and validation of all equipment, in coordination with VA personnel. All work must be conducted during normal business hours (8:00 AM to 4:30 PM, Monday through Friday, excluding Federal Holidays), unless otherwise coordinated.
The contractor must preserve and protect all existing structures, equipment, and utilities during installation, and is liable for any damage incurred. Coordination with the VA point of contact and the general construction contractor is mandatory to ensure safety and minimize interference with other ongoing activities.
**Contracting Entity and Contact Information**
- **Contracting Office:** 255-NETWORK CONTRACT OFFICE 15 (36C255), Department of Veterans Affairs
- **Place of Performance:** Columbia, Missouri (with delivery and installation at Rolla, MO)
- **Primary Contact:** Ashley N Schmitt ([email protected])
- **Solicitation Status:** Active
- **Response Deadline:** September 3, 2026
**Special Considerations**
- This procurement is a SDVOSBC set-aside, restricting competition to eligible Service-Disabled Veteran-Owned Small Businesses.
- All equipment must be the latest standard production models from manufacturers of record, with full compliance to the VA’s Electronic Health Record Modernization Standardization requirements (per memorandum dated March 6, 2025).
- The government reserves the right to modify locations and requirements as operational needs evolve, with any necessary contractual adjustments handled through formal modification processes.
**Summary**
This opportunity represents a significant contract for qualified SDVOSBs specializing in surgical and medical instrument manufacturing and integration. The successful contractor will play a critical role in equipping a new VA outpatient facility with advanced surgical technology, ensuring compliance with stringent clinical, safety, and operational standards. Interested parties should carefully review the detailed technical specifications, delivery and installation requirements, and warranty obligations to assess alignment with their capabilities and experience.
For full solicitation details and attachments, contractors should refer to the official notice on SAM.gov (Opportunity ID: 5754c3ad0a9e456b9d1dcfa7522c03e2).