J065--FY26 Elekta

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

257-NETWORK CONTRACT OFFICE 17 (36C257)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C25726Q0841

NAICS

811210 - Electronic and Precision Equipment Repair and Maintenance

Classification Code

J065

Additional Details
Set Aside

None

Place of Performance

San Antonio, Texas, UNITED STATES

SourceSAM
Documents2
The Department of Veterans Affairs (VA), through its South Texas Healthcare System in San Antonio, Texas, is conducting market research to identify qualified sources for a comprehensive maintenance and support agreement for Elekta Versa HD and associated systems. This Sources Sought Notice (Procurement Identifier: 36C25726Q0841) is issued strictly for informational and planning purposes and does not constitute a solicitation or a commitment by the Government. The intent is to assess the availability and technical capability of potential contractors, particularly those classified as service-disabled veteran-owned small businesses (SDVOSB), veteran-owned small businesses (VOSB), small businesses, HUBZone, 8(a), women-owned, or large businesses, in accordance with NAICS code 811210 (Electronic and Precision Equipment Repair and Maintenance). **Purpose and Scope** The primary objective of this procurement is to secure a firm-fixed price contract for preventive and corrective maintenance services for the Elekta Versa HD linear accelerator and related systems, including Monaco, HexaPOD, ABC, and Mosaiq, located at the South Texas Veterans Healthcare System (Site ID 30000079_CMS). The contract will encompass a base year with four option years, ensuring continuity of high-quality maintenance and support services to sustain optimal system performance and patient care delivery. **Key Requirements and Deliverables** Contractors will be responsible for providing all necessary materials, tools, labor, travel, and equipment to deliver both preventive and corrective maintenance. The scope of services includes: - **Gold Level Service** for Versa HD, TPS (Treatment Planning System), OIS (Oncology Information System), and ABC (Active Breathing Coordinator), with each system requiring 12 months of coverage per contract year. - **Preventive Maintenance (PM):** Annual PM visits scheduled during normal business hours (Monday through Friday, excluding federal holidays), in accordance with manufacturer and regulatory standards. - **Corrective Maintenance (Emergency Support):** On-site technical support by vendor-certified engineers for urgent technical issues, with all travel and parts included. - **Hardware/Software Support:** Installation of all mandatory software and hardware safety releases, updates, and upgrades as declared by Elekta, to maintain safe and effective operation. - **Spare Parts and Unique Components Coverage:** Provision and installation of genuine Elekta parts, including unique components such as imaging panels, X-ray tubes, ion chambers, MLC cameras, magnetrons, thyratrons, image intensifiers, and electron guns. - **System Uptime Guarantee:** Annual uptime targets for the linear accelerator, with a defined discount structure if uptime falls below specified thresholds. - **Remote and Application Support:** Secure remote access for technical and application support, including proactive alerts, notifications, and access to the Elekta Care Community for training and documentation. - **Documentation and Reporting:** Submission of detailed field service reports within three working days of service, including descriptions of work performed and parts replaced. - **Compliance and Safety:** All services must conform to applicable federal regulations (CFR Part 21), NFPA, OSHA, and OEM standards. Contractors must adhere to VA badging, sign-in, and security protocols. **Contractor Qualifications** Personnel assigned to this contract must be fully qualified, with formal training and at least one year of experience servicing the specific make and model of equipment. All test equipment used must have current calibration certification traceable to OEM standards. Contractors must comply with VA information security, privacy, and records management requirements, ensuring no unauthorized access to VA IT systems or patient health information. **Contracting Entity and Contact Information** - **Contracting Office:** 257-NETWORK CONTRACT OFFICE 17 (36C257), Department of Veterans Affairs - **Place of Performance:** San Antonio, Texas, United States - **NAICS Code:** 811210 (Electronic and Precision Equipment Repair and Maintenance) - **Product Service Code:** J065 - **Primary Contact:** Oneka Robertson, Email: [email protected], Phone: 210-694-6318 **Procurement Type and Special Considerations** This notice is for market research only and is not a solicitation. The Government is considering both open market and Federal Supply Schedule sources and is particularly interested in responses from small business concerns, including SDVOSB, VOSB, HUBZone, and 8(a) firms. If a solicitation is issued, it will be posted separately on SAM.gov or GSA E-Buy. Contractors who are authorized distributors or resellers must provide a letter of authorization from the OEM. **Response Instructions** Interested parties are requested to submit capability statements and relevant information to Oneka Robertson at [email protected] by June 13, 2026, 12:00 PM CT. Responses will inform the Government’s acquisition strategy, including potential set-aside determinations. **Summary** This opportunity represents a significant, multi-year requirement for specialized maintenance and support of advanced radiation therapy equipment within a major VA healthcare facility. Contractors with demonstrated expertise in Elekta systems, robust compliance with federal standards, and the ability to provide comprehensive, responsive service are encouraged to respond. The contract will require a high level of technical proficiency, reliability, and adherence to VA protocols to ensure uninterrupted clinical operations and patient safety.