J065--Bayer Medrad Injector Preventive Maintenance Service
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
247-NETWORK CONTRACT OFFICE 7 (36C247)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C24727Q0009
NAICS
811210 - Electronic and Precision Equipment Repair and Maintenance
Classification Code
J065
Additional Details
Documents3
The Department of Veterans Affairs, Veterans Health Administration, through its Network Contracting Office (NCO) 7, is soliciting quotations for preventive maintenance and repair services for Bayer MEDRAD injector systems at the Central Alabama Veterans Health Care System, with locations in Montgomery and Tuskegee, Alabama. This procurement, identified by solicitation number 36C24727Q0009, is classified under NAICS code 811210 (Electronic and Precision Equipment Repair and Maintenance) and Product Service Code J065. The opportunity is set aside for SBA-qualified vendors.
Purpose and Scope:
The primary objective of this contract is to ensure the continued safe, reliable, and compliant operation of Bayer MEDRAD injector equipment used in medical imaging and treatment at VA facilities. The scope encompasses both scheduled preventive maintenance and unscheduled repair services for four specific Bayer MEDRAD injector units, including MARK 7 ARTERION and STELLANT FLEX models. The contractor is responsible for maintaining these devices in accordance with manufacturer specifications and applicable regulatory standards (NFPA-99, OSHA, CDRH, Joint Commission, FDA, ISO 9001).
Intended Outcomes:
The contract aims to minimize equipment downtime, ensure patient and staff safety, and support the VA’s accreditation and compliance requirements. Deliverables include annual preventive maintenance (PM) inspections, timely response to repair requests, comprehensive documentation of all service activities, and provision of OEM parts and software updates. The contractor must guarantee that all work restores equipment to full operational status and meets conformance standards.
Key Requirements and Deliverables:
- Annual PM services scheduled in November, including cleaning, calibration, diagnostics, software/cybersecurity updates, and replacement of worn or faulty parts.
- Unscheduled maintenance with a one-hour phone response and eight-hour on-site response during normal business hours (Monday–Friday, 8:00 a.m.–4:30 p.m., excluding federal holidays).
- All parts, software, and components must be OEM and new; rebuilt or used parts require prior written approval.
- Comprehensive service documentation, including engineering service reports (ESRs) detailing work performed, parts used, and equipment downtime.
- Contractor must provide preventive maintenance/certification inspection procedures for each device model, supporting the facility’s Joint Commission accreditation.
- Personnel must be “fully qualified” Field Service Engineers (FSEs), with recent manufacturer training and at least two years of relevant experience. Subcontractors are not permitted.
- Test equipment used must meet ISO 9001 standards and have current calibration certification traceable to national standards.
- Contractor must comply with VA regulations regarding identification, parking, and conduct while on site.
- Insurance requirements include worker compensation, general liability ($500,000 per occurrence), property damage ($500,000), and medical liability ($1,000,000).
Contract Structure and Evaluation:
The contract is structured as a base year (10/01/2026–09/30/2027) with two one-year options, and payment is made quarterly in arrears. The government will evaluate quotations based on technical capability, OEM authorization and support, personnel qualifications, compliance with the Statement of Work (SOW), past performance, and price. Award will be made to the lowest-priced technically acceptable (LPTA) offeror.
Special Considerations:
- Offerors must demonstrate access to Bayer OEM support, either directly or through documented teaming/subcontracting arrangements with authorized firms.
- All preventive maintenance, repair, and documentation requirements must be met to avoid payment deductions for late or incomplete performance.
- The contractor must accept equipment in “as is” condition and is responsible for all maintenance and repairs unless otherwise specified.
- The government reserves the right to discontinue service on devices meeting replacement criteria with 30 days’ notice.
Contracting Entity and Contact Information:
The procurement is administered by Network Contracting Office 7, located at 2957 Clairmont Road NE, Suite 1200, Atlanta, GA 30329. The primary point of contact is Jessica Cummings, Contracting Officer, reachable at [email protected] or (803) 776-4000 x7801.
Submission Details:
Quotations must be submitted electronically by September 4, 2026, at 12:00 PM Eastern Time. Offerors are responsible for ensuring timely and complete submission, including acknowledgment of all amendments and provision of required technical, pricing, and past performance information.
Summary:
This opportunity represents a comprehensive preventive maintenance and repair contract for Bayer MEDRAD injector systems at VA medical facilities in Alabama. It requires specialized technical expertise, access to OEM support, and strict adherence to regulatory and documentation standards. Contractors with proven experience in medical device maintenance, qualified personnel, and the ability to meet VA requirements are encouraged to review the full solicitation and consider submitting a quotation.
For further details and access to solicitation documents, visit the SAM.gov opportunity page at https://sam.gov/opp/5a478aa5bab3481186e46cce9dc02851/view.