4510--Newington Fire Suppression and Steam Leak Repairs

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

241-NETWORK CONTRACT OFFICE 01 (36C241)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24126Q0691

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Classification Code

4510

Additional Details
Set Aside

SDVOSBC

Place of Performance

Newington, Connecticut, UNITED STATES

SourceSAM
Documents4
The Department of Veterans Affairs (VA), through its 241-Network Contract Office 01, is soliciting qualified contractors for the "Newington Fire Suppression and Steam Leak Repairs" project, located in Newington, Connecticut. This procurement is issued as a Combined Synopsis/Solicitation under procurement identifier 36C24126Q0691 and is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), in accordance with federal set-aside requirements. The primary objective of this project is to address critical repairs to the fire suppression and steam distribution systems within the Newington facility. The scope of work encompasses the replacement and repair of leaking steam and sprinkler piping, including the removal of a leaking valve and its replacement with straight pipe, as well as the restoration of affected systems to full operational status. All work must be performed in compliance with the VA’s Technical Information Library (TIL) standards, and the Statement of Work (SOW) outlines that this is a maintenance and operations (M&O) repair, not a design-build project. Key requirements for this procurement include: - The contractor may assign a superintendent to serve concurrently as the Site Safety and Health Officer (SSHO) and Quality Assurance/Quality Control (QA/QC) representative, provided their credentials and relevant VA site experience are submitted for review and approval. - Proposals should exclude sales tax unless otherwise specified in the solicitation. - Compliance with the prevailing wage determination in effect at the time of contract award is mandatory and will remain constant throughout the project duration. - Contractors are responsible for field verification of all system dimensions and conditions, as no as-built drawings or design documents are available. All necessary data should be collected during the pre-bid walkthrough. - The scope is limited to a maximum of six linear feet of piping replacement, with final quantities to be confirmed on site. The leaking valve within the steam line is to be permanently removed and replaced with straight pipe; no new valves are to be installed in its place. - No priming or painting of new or existing piping, valves, or hangers is required as part of this repair. - The use of existing restroom facilities within reasonable proximity to the work area will be authorized for contractor staff; portable toilets are not permitted on site. - If suspect materials (such as asbestos) are encountered, the contractor is responsible for careful removal and containment for facility testing and proper disposal. Work will be paused and only resumed upon authorization if hazardous materials are confirmed. - All work must be scheduled and completed safely and efficiently, with every effort made to minimize disruption to utility services. In the event of unforeseen conditions that prevent completion within the scheduled outage, modifications to the work schedule will be coordinated with the VA. The project falls under NAICS Code 238220 (Plumbing, Heating, and Air-Conditioning Contractors) and Product Service Code 4510. The place of performance is Newington, Connecticut. Interested SDVOSB contractors should direct all inquiries and submit proposals to the primary point of contact, Sheena Carlyle, at [email protected] or (423) 926-1171 Ext. 3359. The solicitation and any amendments, including wage determinations and additional clarifications, are available via the official SAM.gov opportunity listing (Opportunity ID: 0b8806de871547209ec14d0581acada7). This opportunity is well-suited for contractors with demonstrated experience in steam and fire suppression system repairs within healthcare or institutional environments, particularly those familiar with VA facility requirements and SDVOSB set-aside procedures. The project’s requirements for field verification, adherence to prevailing wage rates, and compliance with VA standards are expected to remain constant throughout the contract lifecycle.