Routine Fire Safety Systems inspection and testing. (Detectors and Dampers)
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
260-NETWORK CONTRACT OFFICE 20 (36C260)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C26026Q0684
NAICS
541350 - Building Inspection Services
Classification Code
H999
Additional Details
Documents3
The Department of Veterans Affairs, through its 260-Network Contract Office 20 (36C260), has issued a solicitation (Procurement Identifier: 36C26026Q0684) for a non-personal services contract to provide comprehensive fire life safety inspection and testing services at the VA Southern Oregon Rehabilitation Center and Clinics (VA SORCC), located at 8495 Crater Lake Highway, White City, Oregon. This procurement is classified under NAICS code 541350 (Building Inspection Services) and Product Service Code H999, with the place of performance specified as Oregon, United States.
**Purpose and Scope**
The primary objective of this contract is to fulfill VA SORCC’s requirement for a one-time, facility-wide inspection and testing of fire safety systems, specifically focusing on detectors and dampers. This initiative is critical to ensuring the ongoing safety of patients, visitors, and staff by maintaining compliance with National Fire Protection Association (NFPA) standards and other relevant codes. The contract addresses the facility’s need for specialized manpower, equipment, and certifications that are not available in-house, thereby supporting the VA’s commitment to a safe healthcare environment.
**Key Requirements and Deliverables**
The contractor will be responsible for the following core activities:
- **Inspection and Testing:** Conduct thorough inspections and functional testing of all fire detection and damper systems as listed in the “Dampers and Detectors List FY25 [12.5.2025]” (see solicitation attachments). All work must adhere to the latest editions of applicable NFPA codes, manufacturer recommendations, and Joint Commission standards.
- **Documentation:** Maintain detailed records of all inspections, tests, and any discrepancies found. Test results must be provided in a format compliant with NFPA, VHA, and Joint Commission requirements. Any critical discrepancies must be reported immediately to Facility Management Service (FMS).
- **Preventative Maintenance:** Perform preventative maintenance inspections to ensure continued operability and compliance of fire alarm systems and components.
- **Performance Verification:** Within 30 days of contract award, submit a comprehensive inspection, testing, and maintenance program outlining the scope and methodology for all fire suppression, extinguisher, alarm, and signaling systems. This program must be documented and updated with testing records.
- **Notification and Coordination:** Prior to any testing, notify all relevant parties, including monitoring companies, building occupants, VA Police, and FMS safety personnel, to prevent unnecessary emergency responses. Upon completion, notify all parties that testing has concluded.
- **Security and Access:** Contractors and subcontractors must check in with VA Police and FMS before commencing work. Work outside regular hours requires three days’ advance notice to the Contracting Officer for escort arrangements. No photography is permitted without written authorization.
- **System Integrity:** At no time should automatic suppression, smoke, heat detection, or fire alarm systems be impaired without prior coordination with FMS and Facility Safety.
- **Reporting Impairments:** If any device is found to be impaired, the contractor must immediately notify VA safety personnel and the Contracting Officer’s Representative (COR). Repairs are not to be performed without prior written approval; separate repair quotes must be provided as needed.
**Contractor Qualifications**
All work must be performed by factory-trained, qualified personnel who are certified, licensed, or registered by a state or local authority, or by a nationally recognized certification organization. Personnel must demonstrate competence through training and experience acceptable to the authority having jurisdiction. The government reserves the right to reject any personnel deemed unqualified.
**Operational and Security Considerations**
- **Hours of Operation:** Work is to be conducted during normal business hours (Monday through Friday, 8:00 a.m. to 4:30 p.m.), excluding federal holidays. The period of performance is 300 calendar days from the notice to proceed.
- **Security:** Contractor employees will have intermittent, escorted access to VA facilities and will not require access to sensitive or computer information. No background investigation is required.
- **Site Regulations:** Smoking is prohibited on VA property. The VA reserves the right to close the site in the event of a national emergency.
**Contracting Entity and Contact Information**
- **Contracting Office:** 260-NETWORK CONTRACT OFFICE 20 (36C260), Department of Veterans Affairs
- **Primary Contact:** Brian Stephen ([email protected])
- **Notice Status:** Active
- **Response Deadline:** August 14, 2026, 19:08
- **Notice URL:** [https://sam.gov/opp/96fff9dc3b574fa5b9e410eca205de90/view](https://sam.gov/opp/96fff9dc3b574fa5b9e410eca205de90)
**Summary for Contractors**
This opportunity is well-suited for firms with demonstrated expertise in fire safety system inspection, testing, and maintenance, particularly those with experience in healthcare or government facilities. Contractors must be able to provide qualified, certified personnel and adhere to stringent regulatory, security, and operational requirements. The contract’s scope is clearly defined, with a focus on compliance, documentation, and coordination with VA facility staff. Interested parties should review all solicitation attachments for detailed requirements and ensure their capabilities align with the outlined expectations before responding.