45--CALCIUM THIOSULPHATE INJECTION SYSTEM

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

OFFICE OF ACQUISITON GRANTS

Contract Value

Not provided

Codes & Classification
Solicitation Number

140G0326Q0190

NAICS

333914 - Measuring, Dispensing, and Other Pumping Equipment Manufacturing

Classification Code

4510

Additional Details
Set Aside

SBA

Place of Performance

-

SourceSAM
Documents3
The U.S. Geological Survey (USGS), under the Department of the Interior, has issued a solicitation (Procurement Identifier: 140G0326Q0190) for the procurement of a Calcium Thiosulphate Injection System. This opportunity, classified under NAICS code 333914 (Measuring, Dispensing, and Other Pumping Equipment Manufacturing), is set aside for SBA-eligible entities and is managed by the Office of Acquisition Grants. The primary point of contact for this procurement is Elizabeth Adam ([email protected], (916) 278-9441). Purpose and Scope: The primary objective of this procurement is to replace an existing sulfur dioxide (SO₂) gas dechlorination system with a modern pump skid capable of injecting liquid calcium thiosulfate (CaTS) into an existing process water carrier line. This system is essential for the dechlorination of laboratory lake process water prior to its discharge, ensuring compliance with environmental and operational standards. The new system will enhance safety and operational efficiency by transitioning from gaseous SO₂ to a liquid dechlorination agent. Key Requirements and Deliverables: - The system must inject NSF-certified liquid calcium thiosulfate (30% w/v, 24% w/w, specific gravity 1.22–1.32, approx. 10.4 lb/gal) into a low-flow carrier line (1/2" Schedule 80 PVC) that feeds into a process water culvert/mixing basin. - The injection system must be capable of precise, low-flow dosing, with an operational range of approximately 0.10–0.23 GPH, consistent with a high-turndown, low-flow peristaltic metering pump as specified in the Statement of Need (SON). - The system must be configured for chemical draw-down from a 275-gallon tote, with all necessary suction and discharge hardware provided. - The offeror is responsible for supplying a complete injection assembly, including diffuser/injection quill, fittings, and all materials compatible with liquid CaTS and the existing PVC carrier line. Existing SO₂ hardware is not to be reused. - The system must interface with facility utilities: 115V/60Hz single-phase power (NEMA 5-15 receptacle) and Siemens Desigo BMS controls, supporting 4–20 mA input/output signals, remote start/stop, alarm, and run/status outputs. - No additional drawings, specifications, or P&IDs will be provided beyond the SON. A site walk is not offered; all scoping and quoting must be based on the SON and supplemental process data provided in the solicitation. Process and Application Details: - The process water flow ranges from 125–250 GPM (typical 150 GPM), with chlorine residuals typically at 2.25 ppm but potentially reaching up to 3 ppm. - The system replaces a dechlorination duty of approximately 9 lb/day SO₂ gas, with estimated CaTS dosing requirements ranging from 2.5 to 5.5 gallons per day, depending on flow and chlorine load. - The injection occurs on a slipstream (carrier line), not the full process flow, ensuring efficient chemical usage and effective dechlorination. Contracting and Administrative Information: - The solicitation is active, with the due date for quotes extended to August 17, 2026, at 10:00am EDT. - All requirements are governed by the Statement of Need; no further questions will be accepted. - The opportunity is posted on SAM.gov (Opportunity ID: 204990be11d743059f006a3d903a293a), with three attachments available for review. Special Considerations: - This procurement is set aside for SBA-eligible contractors. - Offerors must ensure compatibility with existing infrastructure and provide all necessary components for a turnkey installation. - The scope and requirements are fixed as per the SON and will remain constant throughout the contract lifecycle. This opportunity is well-suited for contractors with expertise in chemical injection systems, particularly those experienced with low-flow, high-precision metering pumps and integration with facility management systems. Interested parties should review the Statement of Need and supplemental process data carefully to ensure compliance with all technical and operational requirements.