FPC Yankton - Above Ground Storage Tanks Project 26Z4AH3

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

FPC YANKTON

Contract Value

Not provided

Codes & Classification
Solicitation Number

15B41626Q00000010

NAICS

237120 - Oil and Gas Pipeline and Related Structures Construction

Classification Code

Y1NA

Additional Details
Set Aside

NONE

Place of Performance

Yankton, South Dakota, UNITED STATES

SourceSAM
The Federal Bureau of Prisons, FPC Yankton, has issued a combined synopsis/solicitation (Solicitation No. 15B41626Q00000010) for the Above Ground Storage Tanks Project 26Z4AH3. This procurement seeks a qualified contractor to provide all necessary equipment, labor, materials, and incidentals to replace an existing underground fuel tank with a new aboveground storage tank and fuel dispensing system at the Federal Prison Camp in Yankton, South Dakota. The scope of work encompasses both the decommissioning of the current underground fuel storage infrastructure and the installation of a modern, compliant aboveground system. Key tasks include notifying the Department of Agriculture and Natural Resources (DANR) 30 days prior to tank removal, decommissioning and safely isolating the existing fuel dispenser system, and disconnecting all electrical wiring in accordance with NFPA 70 standards. The contractor is responsible for pumping out and disposing of all remaining fuel and residues per API RP 1604, rendering the 2,500-gallon underground tank vapor-free, and excavating and removing the old tank, piping, and Gasboy pump. A certified site assessment with soil sampling is required, with results submitted to DANR to obtain a closure letter. Following demolition, the contractor will backfill the excavation to 95% standard proctor density, grade for a new tank pad, and install a 6-inch compacted stone base. The new installation includes pouring an elevated, reinforced 6-inch thick, 4000 psi concrete pad with #4 rebar to support a horizontal, 3,000-gallon split compartment double-wall aboveground storage tank (500 gallons diesel, 2,500 gallons unleaded), UL 142 listed. The tank must be anchored and equipped with atmospheric and emergency vents, a level gauge, anti-siphon valve, ground-level fill with spill containment, continuous leak detection, overfill prevention valve, electronic tank gauge with high-level alarm, field-mounted driver gauge, and a graduated gauging rod. Additionally, the contractor will construct a raised concrete fuel island pad and install two new Gasboy 9823K-F Astra (or equal) fuel dispensers with pulse output functionality, including all associated UL-listed hoses, breakaways, nozzles, dispenser sumps, and entry boots. The dispensers must be calibrated, tested, and certified by Weights & Measures. The system will be integrated with a new automated fuel tracking system, featuring a key fob reader and data entry terminal at the island, connected to a controller in the Garage Office and backed up by a generator. The contractor must provide 30 unique vehicle key fobs and 2 general key fobs. Final steps include pressure/leak testing and installation of protective concrete-filled steel bollards around the tank and dispensing area. The performance period for this project is 161 calendar days from the issuance of the notice to proceed. The applicable NAICS code is 237120 (Oil and Gas Pipeline and Related Structures Construction), with a small business size standard of $45 million. There is no set-aside for this procurement; it is open to all responsible entities. All solicitation documents and future amendments will be available exclusively through the Contract Opportunity website at https://www.sam.gov. Access to secure documents requires active SAM registration and a valid MPIN. Contractors must ensure their SAM registration is current and that the relevant NAICS code is included in their profile. Questions regarding access should be directed to the Federal Service Desk at 866-606-8220. Interested vendors are encouraged to attend a site visit at FPC Yankton, with attendance contingent upon submission and approval of NCIC background check forms for all proposed attendees. The site visit is scheduled for Thursday, August 20, 2026, at 9:00 AM CDT. All questions must be submitted in writing to the Contracting Officer; no questions will be answered during the site visit. Quotations are due by Monday, August 31, 2026, at 9:00 AM CDT. Offerors must include a specification sheet and all relevant submittal information with their quotation. Faxed and hand-delivered quotes will not be accepted. Payment will be processed via Electronic Funds Transfer (EFT) in accordance with FAR 52.232-33. The contracting entity is FPC Yankton, under the Federal Bureau of Prisons, Department of Justice. The primary point of contact is Michael Peitz ([email protected], 605-665-3262 ext. 1133), with secondary contact Karen Miller ([email protected], 605-665-3262 ext. 1114). This opportunity is ideal for contractors with experience in fuel storage tank removal and installation, site remediation, and integration of automated fuel management systems, particularly those familiar with federal, state, and industry standards for environmental safety and compliance. Interested parties should review the full Statement of Work and solicitation documents on SAM.gov for complete requirements and submission instructions.
Documents6