J041--Converter 1 Repairs HVAC Deficiencies - NWI (VA-26-00071465)
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
NETWORK CONTRACT OFFICE 23 (36C263)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C26326Q0992
NAICS
238220 - Plumbing, Heating, and Air-Conditioning Contractors
Classification Code
J041
Additional Details
Documents3
The Department of Veterans Affairs (VA), through its Network Contracting Office 23 (NCO 23), has issued a combined synopsis/solicitation for the repair of HVAC deficiencies associated with Converter 1 at the VA Nebraska-Western Iowa (NWI) Health Care System, located in Omaha, Nebraska. This procurement, identified under solicitation number 36C26326Q0992, is classified under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors), and is set aside for small business concerns in accordance with SBA guidelines.
The primary objective of this procurement is to address and remediate specific HVAC deficiencies to ensure optimal environmental control and compliance with healthcare facility standards. The scope of work includes, but may not be limited to, the repair and possible replacement of HVAC components associated with Converter 1, with a focus on maintaining critical air quality and infection control standards within sensitive areas of the medical facility.
Key requirements and deliverables for this project include:
- Execution of all necessary repairs to restore HVAC functionality and address identified deficiencies.
- Strict adherence to infection control protocols, including the use of appropriate containment measures such as stark walls, poly sheeting, or blue adhesive mats to demarcate work areas. The contractor is responsible for providing all necessary materials and equipment for these measures, with the exception that the VA can provide a HEPA cart if required.
- Specific areas requiring enhanced containment (either stark wall or poly) include Operating Rooms 5 and 7, the PACU #4064 lobby, and Building 9 Dialysis.
- Coordination with VA Engineering for completion of Pre-Construction Risk Assessment (PCRA) and Infection Control Risk Assessment (ICRA) paperwork prior to commencement of work. The VA will handle the paperwork, but the contractor must notify the VA in advance to ensure timely completion.
- Flexibility in containment methods, as the VA has confirmed that poly sheeting at the door or the use of HEPA carts within the room are acceptable alternatives to working exclusively from an ICRA cabinet.
The place of performance for this contract is Omaha, Nebraska, at the VA NWI Health Care System. The anticipated outcomes of this project are the restoration of compliant HVAC operations, improved environmental safety, and minimized disruption to ongoing healthcare services.
The contracting entity for this opportunity is the Department of Veterans Affairs, Network Contracting Office 23, located at 1303 5th Street, Suite 300, Coralville, IA 52241. The primary point of contact for this solicitation is Amanda Patterson-Elliott, who can be reached at [email protected] or by phone at 319-688-2578.
This procurement is currently active, with a response deadline of August 18, 2026, at 3:08 PM. Interested contractors should review all solicitation documents and amendments, including the government’s responses to technical questions, to ensure full compliance with submission requirements and project specifications.
Contractors considering this opportunity should have demonstrated experience in healthcare facility HVAC repair, a strong understanding of infection control protocols, and the ability to coordinate effectively with VA engineering and administrative staff. The project’s requirements for specialized containment and infection control measures are critical and will remain constant throughout the contract lifecycle.
For further details and access to solicitation attachments, interested parties should refer to the official notice on SAM.gov at https://sam.gov/opp/5a095019c4ba443b8a8e502f69c2a512/view.