Homestead Air Reserve Base B121 - B122 Hallway Connection
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
FA6648 482 LSS LGC
Contract Value
Not provided
Codes & Classification
Solicitation Number
FA664826SS0002
NAICS
236220 - Commercial and Institutional Building Construction
Classification Code
Z2AA
Additional Details
Documents1
The Department of the Air Force, through the 482nd Logistics Support Squadron (LSS) Contracting Office at Homestead Air Reserve Base (HARB), Florida, is conducting market research via a Sources Sought Synopsis for a significant design-build construction project titled "KYJM 17-9010 Repair and Connect B-121 to B-122 for EOD." This notice, identified by procurement number FA664826SS0002, is intended solely to assess the capabilities and interest of qualified firms and does not constitute a solicitation or request for proposals.
The primary objective of this procurement is to engage a design-build contractor capable of delivering comprehensive design and construction services to connect two existing buildings (B-121 and B-122) at HARB. The project encompasses a broad scope of work, including demolition, restoration, alterations, additions, and interior and exterior finishes, all tailored to meet the mission requirements of the Explosive Ordnance Disposal (EOD) unit.
Key deliverables and requirements include:
- **Design-Build Documentation:** Preparation and submission of 65%, 100%, and final certified design packages, adhering to Unified Facilities Guide Specifications (UFGS) and signed/sealed by Florida-registered Professional Engineers and Architects.
- **New Hallway Addition:** Construction of an enclosed hallway linking B-121 and B-122, featuring interior office finishes (carpet, lighting, electrical, fire sprinkler, and lightning protection systems), a standing seam metal roof, and insulated/painted walls.
- **Site Work and Canopy:** Extension of the asphalt area and installation of a 35' x 28' x 16' clear-span canopy (without columns) to accommodate three mobility vehicles. This includes a professional geotechnical study, grading/drainage plans (maximum 2% slope), and installation of heavy-duty black polyethylene bird netting.
- **Perimeter Security:** Installation of a chain link fence with one double vehicle gate, two single personnel gates, and specialized security lock hardware.
- **Complex HVAC Systems:** Installation of a new, highly efficient Carrier air-cooled chiller (ACCH-1) with copper/copper coils (8,000-hour salt spray resistance), multi-zone variable airflow chilled water systems, DX mini-splits for communications closets, and a Bacnet DDC control system compatible with HARB’s WebCTRL 7.0 AutomatedLogic license.
- **Roof Replacement:** Design and installation of a new standing seam metal roof system (R-30 insulation) for warehouse and administrative buildings 121 and 122, compliant with Miami-Dade County high-velocity wind zone standards (minimum 150 mph wind speed/150 psf uplift pressure) and a 20-year single-source water-tightness warranty.
- **Specialized Security and Administrative Spaces:**
- Construction of a secure open storage space in B-122 with reinforced walls, no windows, GSA-approved security locks, and hardened utility openings.
- Creation of a secure briefing and training room in B-122 for up to 35 personnel, meeting military security, access control, and acoustic shielding standards.
- Development of a 2,400 sq/ft climate-controlled equipment bay in B-121 for specialized mobility packages, with strict environmental controls and physical separation from administrative areas.
- Maintenance and integration of secure communications infrastructure throughout the facility.
- **Operational Constraints:** Continuous, uninterrupted electrical power must be maintained for all high-security storage areas and associated alarm systems throughout the project duration.
The estimated magnitude of construction is between $1,000,000 and $5,000,000. The applicable NAICS code is 236220 (Commercial and Institutional Building Construction), with a small business size standard of $45.0 million. The Product Service Code is Z2AA (Repair or Alteration of Office Buildings). The period of performance is set at 540 calendar days from the Notice to Proceed.
Interested firms are invited to submit a capability statement (maximum five pages) demonstrating their ability to fulfill the requirements. Submissions should include company profile details (name, address, point of contact, CAGE code, UEI, business size and socio-economic status), bonding capacity, and summaries of up to three relevant past projects of similar size, scope, and complexity—particularly those involving design-build work on military installations, secure administrative spaces, high-velocity wind zone roofing, and complex chilled-water HVAC systems.
All responses must be submitted electronically to Contract Specialist Tahj Guilford at [email protected] by 4:00 PM EST on August 7, 2026. The subject line should read "Sources Sought Response: KYJM 17-9010 Repair and Connect B-121 to B-122." Questions should be directed to the provided email address; telephone inquiries will not be accepted.
This opportunity is an important market research effort for the Air Force and may inform future procurement strategies. Contractors with relevant experience and capacity are encouraged to respond to help shape the requirements and potential set-aside determinations for this project.
For further details, refer to the official notice at: https://sam.gov/opp/67ecad93b7c14eddb80eb80879f7ccd7/view