Bulk Oil/Coolant Storage & Dispenser System

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

FA4528 5 CONS

Contract Value

Not provided

Codes & Classification
Solicitation Number

FA452826QSP03

NAICS

332420 - Metal Tank (Heavy Gauge) Manufacturing

Classification Code

5430

Additional Details
Set Aside

SBA

Place of Performance

Minot AFB, North Dakota, UNITED STATES

SourceSAM
The Department of the Air Force, through the 5th Contracting Squadron (5 CONS) at Minot Air Force Base, North Dakota, is seeking quotes for the delivery of a modular bulk oil and coolant storage and dispensing system. This procurement, identified under FA452826QSP03, is issued as a combined synopsis/solicitation and is set aside for Small Business Administration (SBA) participants, in accordance with the applicable set-aside requirements. The primary objective of this procurement is to acquire a turnkey fluid storage and dispensing solution that will enhance the facility’s capability to safely and efficiently store and dispense multiple types of oil and coolant. The system must be modular in design and delivered ready for installation, with all components meeting the essential characteristics detailed in the solicitation attachments. Key requirements for the system include: - **Footprint and Construction**: The system must fit within a 12-foot wide by 9-foot deep by 10-foot high space and utilize four 120-gallon aluminized steel tanks (three designated for oil, one for coolant). The tanks must be color-coded (three black for oil, one blue for coolant) for clear identification and safety. - **Operation**: The entire system must operate solely on facility-supplied compressed air, eliminating the need for electrical power and ensuring compatibility with existing infrastructure. - **Fluid Handling**: The system must accommodate three distinct oil types and one coolant, with dedicated storage and dispensing lines for each. - **Pumping and Dispensing**: Two pneumatic pumps are required—an air-operated double diaphragm (AODD) pump for the coolant line and a gear or piston pump for the oil line. The oil pump must draw from a selector manifold that connects the three oil tanks, utilizing three two-way isolation ball valves to select the desired oil and prevent cross-contamination. - **Hose Reels**: Two 50-foot hose reels are specified—one dedicated to coolant and one shared among the three oil types. - **Line Purge/Flush Capability**: The oil hose reel system must include a purge or return line, equal in diameter to the dispensing hose, to clear residual fluid when switching between oil types, thereby maintaining product integrity. - **Filtration**: Both oil and coolant lines must be equipped with independent, inline 10-micron filters, each with isolation valves to ensure effective filtration and ease of maintenance. - **Safety and Environmental Controls**: The system must incorporate color-change desiccant breathers, isolated sight gauges for fluid level monitoring, drip pans, and a spill containment pallet with a minimum capacity of 130 gallons to mitigate environmental risks and ensure compliance with safety standards. The government will consider “or equal” products, provided all specified characteristics and performance requirements are met. Contractors are encouraged to review the seven attachments available on the SAM.gov opportunity page for detailed technical specifications and compliance criteria. This opportunity is classified under NAICS code 332420 (Metal Tank [Heavy Gauge] Manufacturing), with a Product Service Code of 5430. The place of performance is Minot Air Force Base, North Dakota. Interested vendors should direct all inquiries to the primary point of contact, Sherry L. Platt ([email protected], 701-723-2139), or the secondary contact, Ted Arneson ([email protected], 701-723-3949). The solicitation is active, with a response deadline of July 30, 2026, at 16:07. This procurement represents a critical infrastructure enhancement for Minot AFB, supporting safe, efficient, and environmentally responsible fluid management. Contractors with experience in modular fluid storage systems, pneumatic dispensing technology, and compliance with federal safety and environmental standards are encouraged to review the full solicitation and attachments to determine alignment with their capabilities.
Documents7