Pad-Mounted Transformer

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

W6QM MICC-FT DRUM

Contract Value

Not provided

Codes & Classification
Solicitation Number

W911S226U3773

NAICS

335311 - Power, Distribution, and Specialty Transformer Manufacturing

Classification Code

6120

Additional Details
Set Aside

SBA

Place of Performance

-

SourceSAM
The Department of the Army, through the Mission and Installation Contracting Command at Fort Drum (W6QM MICC-FT DRUM), has issued a combined synopsis/solicitation for the procurement of a pad-mounted transformer to be delivered to Fort Buchanan, Puerto Rico (ZIP code 00934). This opportunity, identified by procurement number W911S226U3773, is classified under NAICS code 335311 (Power, Distribution, and Specialty Transformer Manufacturing), with a Product Service Code of 6120. The solicitation is set aside for SBA-eligible contractors. The primary objective of this procurement is to furnish and deliver one (1) pad-mounted, dead front, radial transformer with a capacity of 750 kVA. The transformer must be three-phase, with a primary voltage of 13,200 V (15 kV class) and a secondary voltage of 208Y/120 V, operating at 60 Hz. The unit must utilize ONAN cooling and be filled with mineral oil. The transformer is required to arrive fully assembled and ready for installation, with a minimum one-year manufacturer warranty covering equipment defects. Key requirements and deliverables include: - **Physical Dimensions:** The transformer must have a height of 63½ inches (up to 64½ inches) and a width of 65 inches. The depth may vary, but the existing installation is 41 inches. Contractors must confirm manufacturing dimensions in their proposal, either in writing or via shop drawings, for government approval. - **Mechanical and Construction Features:** The transformer must feature a stainless steel tank, cabinet, and hardware (304 grade), dead front construction, pentahead security hardware, ANSI 61 grey color, welded and pressure-tested tank, a 1-inch oil drain valve with a 3/8-inch water sampler on the primary side, arc-flash and safety labeling, lifting lugs, jacking pads, and a nameplate per ANSI C57.12.00. - **Electrical Specifications:** The unit must include six (6) 200A load break wells with inserts for three (3) low voltage and three (3) 10kV arresters on the primary side, NEMA spade with support terminals (10 holes: three LV and one neutral) on the secondary side, radial feed configuration, standard ANSI impedance values for 750 kVA, and a standard five-position no-load tap changer (±2 x 2.5%). - **Protection and Monitoring:** Required features include a bayonet fuse with isolation link, current limiting fuses, a minimum two-position load break switch, nitrogen pressure gauge with test port and blanket, temperature gauge, pressure vacuum gauge, liquid level indicator, and Schrader valve. All gauges must be visible. - **Compliance:** The transformer must comply with ANSI/IEEE C57.12 series, DOE 2016 efficiency standards, National Electrical Safety Code (NESC), National Electrical Code (NEC/NFPA 70), UFGS 26 12 19, the American Buy Act, and must be PCB-free and UL Listed. - **Testing and Documentation:** The contractor must provide factory routine test reports and documentation, including insulation resistance, winding resistance, turns ratio, polarity and phase-relation, no-load and load-loss, dielectric, excitation, impedance, applied and induced potential, leak, and oil quality tests. Certified as-built drawings, a certified test report signed by the manufacturer, installation and O&M manuals, and warranty documentation are also required. - **Delivery and Packaging:** The transformer must be delivered to Fort Buchanan, Puerto Rico, within 40 weeks of contract award. The packing slip must include the contract number, purchase order number, and serial number. The contracting office is seeking proposals from qualified SBA-eligible vendors capable of meeting these stringent technical and compliance requirements. Interested parties should note the mandatory physical dimensions, compliance standards, and documentation deliverables, as these elements are critical and non-negotiable throughout the contract lifecycle. The point of contact for this solicitation is Diana Ruiz, who can be reached at [email protected]. The notice was posted on July 22, 2026, with responses due by July 29, 2026, at 20:07. Further details and updates can be accessed via the official SAM.gov opportunity page: https://sam.gov/opp/6d4854cba1ee4d9b97f4c3b948aee2ca/view. This procurement represents a significant opportunity for manufacturers and suppliers specializing in medium voltage, pad-mounted transformers who can demonstrate compliance with federal standards and deliver robust, high-quality equipment within the specified timeframe.