Single-Axis Linear Motion Calibration System (Shake Table) with Control Software
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
FDA OFFICE OF ACQ GRANT SVCS
Contract Value
Not provided
Codes & Classification
Solicitation Number
SSN-CDRH-2026-133952
NAICS
334519 - Other Measuring and Controlling Device Manufacturing
Classification Code
6625
Additional Details
Documents2
The U.S. Food and Drug Administration (FDA), under the Department of Health and Human Services, has issued a Sources Sought Notice (Procurement Identifier: SSN-CDRH-2026-133952) to identify potential suppliers for a Single-Axis Linear Motion Calibration System (Shake Table) with integrated control software. This market research effort is intended to inform the FDA’s acquisition strategy and assess the availability of domestic sources capable of meeting the agency’s technical and regulatory requirements, as well as to determine whether a small business set-aside is feasible.
**Purpose and Scope**
The FDA seeks to procure a turnkey, single-axis (one degree-of-freedom) linear motion calibration system, commonly referred to as a shake table, for laboratory calibration, verification, and validation testing of inertial measurement devices. The system must be delivered fully assembled, factory-tested, and factory-calibrated, requiring only minimal setup by the end user (unpacking, cable connection, and software installation). The anticipated quantity is one (1) unit, with delivery expected within approximately 90 days after award to the FDA White Oak campus in Silver Spring, Maryland.
**Key Requirements and Expected Deliverables**
The system must meet the following salient performance characteristics:
- **Programmable Motion:** Single-axis linear motion under closed-loop position control with real-time feedback, capable of arbitrary user-defined waveforms, including multi-frequency superposition of at least three simultaneous components. Pre-programmed, fixed-routine-only calibrators are not acceptable.
- **Motion Envelope:** Frequency range of approximately 0.1 to 10 Hz, displacement from sub-millimeter up to about twenty millimeters, and acceleration up to approximately one g. The system must demonstrate small-amplitude positioning accuracy at the sub-millimeter level.
- **Integrated Sensors:** Factory-calibrated position sensor and reference accelerometer, each with NIST-traceable calibration certificates.
- **Safety Features:** Hard-wired emergency stop, motion limits, over-current protection, and fault detection with automatic safe shutdown.
- **Form Factor and Power:** Benchtop design suitable for standard laboratory power (110 to 120V or universal input), with no requirement for special power conditioning or floor reinforcement.
- **Control Software:** Standalone operation (no internet/cloud/subscription required), programmable interface compatible with MATLAB, Python, or equivalent industry-standard environments, and non-proprietary data import/export capabilities.
- **Accessibility:** Software and electronic content must conform to Section 508 accessibility standards, supported by a Voluntary Product Accessibility Template or equivalent.
- **Additional Deliverables:** Installation, user training, technical documentation, and a commercial warranty are included in the anticipated requirement.
**Contracting Entity and Location**
The procurement is managed by the FDA Office of Acquisition and Grant Services, located at the FDA White Oak campus in Silver Spring, Maryland (NAICS Code: 334519 – Other Measuring and Controlling Device Manufacturing; PSC: 6635 – Physical Properties Testing and Inspection). The primary point of contact is Reagan Davis ([email protected], 301-796-0910).
**Procurement Type and Special Considerations**
This notice is strictly for market research purposes and does not constitute a solicitation or a commitment to issue one. The FDA is seeking responses from all business sizes, with particular interest in identifying capable small business concerns (including manufacturers, OEMs, authorized distributors, or resellers) to support potential set-aside decisions under FAR Part 19. The notice also supports the Government’s obligations under the Buy American statute and FAR Part 25, with an emphasis on domestic end products.
Respondents are instructed to submit a completed Vendor Response Form (in native Microsoft Excel format) and a capability statement (up to five pages in PDF), detailing their ability to meet the requirements, relevant experience, manufacturing location(s), and compliance with domestic content thresholds. Responses must be submitted via email to the designated contact by the specified deadline. Telephone inquiries will not be accepted.
**Constant Elements Over Contract Lifecycle**
Throughout the contract lifecycle, the requirement for a fully functional, factory-calibrated, and NIST-traceable single-axis shake table with robust safety features, accessible control software, and compliance with Section 508 standards will remain unchanged. The place of performance will consistently be the FDA White Oak campus in Silver Spring, Maryland, and the procurement will be governed by the applicable federal standards and statutes, including those related to domestic sourcing and accessibility.
**Summary for Contractors**
Contractors evaluating this opportunity should ensure their offerings align with the technical specifications, regulatory requirements, and delivery expectations outlined above. The FDA is seeking a reliable, high-precision calibration system suitable for laboratory use, with comprehensive support and documentation. Interested parties should be prepared to demonstrate their manufacturing capabilities, supply chain integrity, and compliance with federal accessibility and domestic content standards. This notice represents a valuable opportunity for qualified firms in the measuring and controlling device manufacturing sector to engage with the FDA and potentially support its critical laboratory calibration needs.