Wilmington VAMC Hood and Duct Cleaning

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

244-NETWORK CONTRACT OFFICE 4 (36C244)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24426Q0777

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Classification Code

J041

Additional Details
Set Aside

SDVOSBS

Place of Performance

Wilmington, Delaware, UNITED STATES

SourceSAM
Documents5
The Department of Veterans Affairs, through its Network Contract Office 4 (NCO 4), has issued a solicitation for professional hood and duct cleaning services at the Wilmington VA Medical Center, located at 1601 Kirkwood Hwy, Wilmington, Delaware. This procurement, identified under Solicitation Number 36C24426Q0777, is specifically set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), reflecting the VA’s commitment to supporting veteran entrepreneurs. The primary objective of this contract is to ensure the thorough cleaning and maintenance of cooking equipment exhaust systems throughout the medical center. The scope of work encompasses quarterly cleaning services for a variety of exhaust hoods, ducts, and associated fans, with all work to be performed in strict accordance with NFPA 96, Chapter I standards. These standards govern the procedures for the use and maintenance of commercial kitchen ventilation control and fire protection systems, ensuring both operational efficiency and safety. Key requirements include the provision of all necessary materials, tools, equipment, supervision, and qualified personnel to perform comprehensive cleaning of the listed systems. The contractor will be responsible for servicing several specific units, including but not limited to: - A 6-foot up-draft grill stand with approximately 75 feet of exhaust duct and a centrifugal exhaust fan mounted on the ICU roof. - A 16-foot wall-mounted canopy hood with approximately 20 feet of exhaust duct and a general-purpose centrifugal exhaust fan above the canteen. - A 16-foot island canopy hood and its auto wash system in the dietetics area, including the roof-mounted exhaust fan. - The dietetics machine in Room 1120, including dish machine exhaust ducts, grills, hoods, and roof-mounted exhaust fan. - Two canopy grill hoods, each with 8-foot ducts and exhaust fans, serving the Community Living Center (CLC). For each cleaning, the contractor must affix certification to each hood and system serviced, demonstrating compliance with applicable standards. Additionally, all exposed kitchen and floor areas must be adequately protected during cleaning, and any dust or debris generated must be thoroughly cleaned up upon completion of the work. Environmental, Occupational Safety, and Health (EOSH) compliance is a critical aspect of this contract. All work must adhere to relevant federal and state regulations, including but not limited to 29 CFR Parts 1910 and 1926 (Occupational Safety for General and Construction Industries), 40 CFR (Protection of the Environment), 49 CFR Part 397 (Transportation of Hazardous Materials), and applicable sections of the Delaware Code related to conservation and health and safety. The procurement is classified under NAICS Code 811310, which covers Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance, and Product Service Code J041. The place of performance is exclusively at the Wilmington VA Medical Center in Delaware. Interested SDVOSB contractors should note that the solicitation has been amended to remove the canteen requirement, and all services must be delivered as specified in the revised scope. The solicitation remains active, with responses due by July 22, 2026, at 2:07 PM. For further information or to submit inquiries, contractors may contact Chris Clements at [email protected] (205-349-9891) or Stephanie Luniewski at [email protected] (412-680-6879). This opportunity represents a recurring, compliance-driven requirement to maintain the safety and operational integrity of the Wilmington VA Medical Center’s kitchen exhaust systems, making it well-suited for contractors with demonstrated expertise in NFPA 96-compliant hood and duct cleaning, strong safety practices, and experience working in healthcare environments.