6515--Patient Transfer Chairs FSS Pre-Solicitation Sources Saught Brand Name or Equal
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
248-NETWORK CONTRACT OFFICE 8 (36C248)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C24826Q0930
NAICS
334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
Classification Code
6515
Additional Details
Documents2
The Department of Veterans Affairs, through its 248-Network Contract Office 8, has issued a Sources Sought notice (Procurement Identifier: 36C24826Q0930) to conduct market research for the anticipated procurement of patient transfer chairs—specifically, the Raizer II Battery Mobile Lifting Chair or an equivalent product—along with associated slings for patient lifts. This notice is intended solely for informational and planning purposes and does not constitute a solicitation or a commitment to issue a solicitation in the future.
The primary objective of this procurement is to enhance patient safety and staff well-being at the C.W. Bill Young VA Medical Center, located at 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, and its associated Community-Based Outpatient Clinics (CBOCs), including Lee County. The facility has identified a critical need for compact, mobile lifting chairs to assist in the safe recovery of patients who have experienced falls but are otherwise medically stable. Currently, staff rely on manual lifting techniques, which pose significant risks of injury and do not comply with Safe Patient Handling and Mobility (SPHM) principles. The introduction of mechanical lifting chairs will provide a controlled, efficient, and safe method for raising fallen patients from the floor to a seated position, thereby reducing the risk of injury to both patients and staff and ensuring compliance with VA Directive 1611, which mandates the availability of fall recovery equipment.
The equipment sought must meet specific physical and functional requirements, including:
- Brand name Raizer II Battery Mobile Lifting Chair or an equivalent product
- Lithium Ion battery-powered operation
- Usable by a single caregiver
- Lifting time of 20-30 seconds
- Minimum lift capacity of 300 lbs (Safe Working Load up to 150 kg)
- Rechargeable with a 12V charger and battery indicator on the panel
- Sound and light indicators for assembly
- Seat width between 25.7 cm and 27 inches
- No foam seats
- Minimum of 75 lifts per single charge
- Aluminum frame construction
- Includes a transport bag for portability
The contractor will be responsible for providing initial training at the time of equipment installation, with additional support for training as needed. The VA’s Safe Patient Handling and Mobility Program Manager will subsequently train staff at each CBOC location. A maintenance warranty of 1-5 years on the equipment is also required.
This notice is classified under NAICS Code 334510 (Electromedical and Electrotherapeutic Apparatus Manufacturing) and Product Service Code 6515. The procurement may be set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), Veteran-Owned Small Businesses (VOSBs), or other small businesses, depending on the responses received. If insufficient responses are received from SDVOSBs or VOSBs, the opportunity may be opened to all eligible businesses.
Interested parties are invited to respond by submitting a capability statement, a letter of authorized supply and distribution, and any other relevant supporting documentation. Responses must be submitted via email to the primary contact, Michael A. Shook ([email protected], 813-927-7566), by 14:00 on August 16, 2026. The information gathered will inform the VA’s acquisition strategy and potential set-aside determination.
This is an active notice, and all interested and qualified vendors are encouraged to review the full opportunity details and attachments available at https://sam.gov/opp/339ab2b88d2a4892bef41c598a0fbde6/view.
Contractors evaluating this opportunity should consider their ability to meet the specified technical requirements, provide timely training and warranty support, and comply with potential set-aside restrictions. The procurement is expected to remain consistent in its focus on patient safety, staff injury prevention, and compliance with VA directives throughout the contract lifecycle.