N063--QUESTIONS & ANSWERS. NURSE CALL SYSTEM FOR DC VAMC. "BRAND NAME OR EQUAL TO IAW SOW". OEM LETTER FROM THE MANUFACTURER IS REQUIRED. IF NO OEM LETTER VENDOR WILL BE CONSIDERED NON-RESPONSIVE.

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

245-NETWORK CONTRACT OFFICE 5 (36C245)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24526Q0598

NAICS

334290 - Other Communications Equipment Manufacturing

Classification Code

N063

Additional Details
Set Aside

SBA

Place of Performance

-

SourceSAM
This procurement opportunity, issued by the 245-Network Contract Office 5 (36C245) under the Department of Veterans Affairs, seeks qualified vendors to provide and install a nurse call system at the Washington, DC VA Medical Center (DC VAMC). The solicitation, identified as 36C24526Q0598, is a combined synopsis/solicitation for a "brand name or equal" nurse call system in accordance with the Statement of Work (SOW). The procurement is classified under NAICS code 334290 (Other Communications Equipment Manufacturing) and Product Service Code N063. **Purpose and Scope** The primary objective of this contract is to replace and expand the existing nurse call system within the DC VAMC’s behavioral health unit. The current system, identified as Rauland 4 nurse call hardware or older, is partially functional due to water damage at call button locations and has been inoperable for over five years. The new system will serve as a standalone solution, not integrated with the facility’s existing nurse call infrastructure, and will provide localized notification through alarm panels. The scope of work includes: - Removal of all existing nurse call cables and equipment. - Installation of a new nurse call system covering four bathrooms, with a total of 20 call buttons (expanding from 14 in three bathrooms to 20 in four bathrooms). - Installation of four dome lights (an increase from the three currently in place). - Provision of high and low push buttons in each location to ensure patient accessibility in the event of a fall, as required for behavioral health units. - All necessary materials, labor, and equipment to complete the installation, including rough-ins and cable runs to the panel. - Installation of all system components in conduit, per VA TIL Section 27-52-23, as nurse call systems are considered critical life safety systems. - Reuse of existing conduit/penetrations where suitable, with the option to install J-hooks as needed. **Key Requirements and Deliverables** - The system must be "brand name or equal" to the specified solution, and an OEM letter from the manufacturer is required with the proposal. Vendors failing to provide this letter will be deemed non-responsive. - The contractor is responsible for determining the location of existing devices, head end equipment, and panels, as no government mark-ups are available. - The contractor must provide a manufacturer’s parts warranty for a minimum of one year and a workmanship warranty for a minimum of three years, covering all deliverables (existing and new devices). - The contractor must coordinate with the facility’s Infection Control to determine the Infection Control Risk Assessment (ICRA) level, which is likely to be Level 2 but may escalate to Level 4 depending on the scope of work. - Delivery and completion of the entire project must occur within 90 days of contract award. - The contractor must submit three past performance references, preferably projects of similar size and scope completed within the last five years. - A completed Buy American Certificate is required for the primary line item to demonstrate compliance with country-of-origin requirements. **Contracting Entity and Submission Details** This opportunity is set aside for SBA-eligible vendors. The contracting entity is the 245-Network Contract Office 5, a federal office under the Department of Veterans Affairs. All quotations must be submitted electronically via email to Mohsin Abbas, Contract Specialist, at [email protected], no later than 3:00 PM EST on June 30, 2026. Late submissions will not be accepted, and it is the vendor’s responsibility to ensure timely receipt. **Special Considerations** - No site visits will be permitted during the RFQ phase; vendors must prepare their proposals based on the SOW and provided documentation. - The system must not include pull cords, as these are not permitted in behavioral health units; only push buttons are acceptable. - The government does not require the inclusion of UPS or backup power supplies as part of this contract. - The warranty requirements are as stated in the SOW and will not be extended to five years unless otherwise amended. - The contractor is responsible for all aspects of installation, including assessment of water damage and ensuring compliance with all applicable VA and federal standards. **Contact Information** - Contract Specialist: Mohsin Abbas - Email: [email protected] **Reference Materials** - The solicitation and all related attachments are available on SAM.gov under Opportunity ID ab27992a1499438f8fa693fa2dcc25fa. This procurement represents a critical infrastructure upgrade to ensure patient safety and operational reliability within the DC VAMC’s behavioral health unit. Contractors with experience in nurse call system installation, particularly in healthcare and behavioral health environments, and the ability to meet the outlined technical and compliance requirements, are encouraged to respond.
Documents8