The U.S. Army Corps of Engineers, Pittsburgh District, is soliciting qualified small business contractors for the repair of a deteriorated concrete section within the stairwell of the Intake Tower at Tionesta Creek Lake. This procurement, titled "Tionesta Dam Control Tower Concrete Repair," is issued under Solicitation Number W911WN26QA043 and is classified under NAICS Code 237990 – Other Heavy and Civil Engineering Construction. The opportunity is a 100% Small Business Set-Aside, with a small business size standard of $45,000,000.
The primary objective of this project is to restore the watertight integrity of the Intake Tower stairwell, thereby preventing water intrusion during high-water events and ensuring safe access for project personnel. The scope of work focuses on a specific area of concrete deterioration located at elevation 1116.5, measuring approximately 8 feet in height, 7 feet in width from the right wall, and at least 8 inches in depth, or until sound concrete is reached.
Key requirements for the contractor include:
- Sounding the concrete to identify and mark the limits of demolition.
- Removing all unsound concrete material.
- Installing a non-shrink, low-pressure injection grout around the full perimeter of the existing concrete to reduce seepage from the gatewell into the stairwell.
- Installing reinforcement, including horizontal, vertical, and bent-hook bars, doweled and epoxied into the existing structure, with a minimum clear cover of three inches.
- Applying a concrete bonding agent to all existing surfaces.
- Installing a hydrophilic waterstop along all vertical and horizontal joints to minimize future leakage.
- Setting formwork flush with the existing wall face and placing new concrete, ensuring full consolidation and a uniform finish through vibration.
The contracting entity for this opportunity is the U.S. Army Corps of Engineers, Pittsburgh District (W072 ENDIST PITTSBURGH), operating under the Department of Defense, Department of the Army. The primary point of contact for this solicitation is Mario Taormina ([email protected], 412-395-7256), with Connie L. Ferguson ([email protected], 412-395-7551) as the secondary contact.
This procurement is governed by the Product Service Code Y1QA and is subject to the updated Wage Determination PA20260002 (effective 07/30/2026). Contractors are encouraged to review the U.S. Army Corps of Engineers’ guidance on equitable adjustments and contract changes, accessible via the provided link in the solicitation.
Interested and capable small business offerors are invited to submit their quotes by the response deadline of October 8, 2026. The solicitation and any associated documents can be accessed through the official SAM.gov opportunity listing (Opportunity ID: 6b3c7bb0281b4d6eb7b39aadad521b8c).
This opportunity is ideal for contractors with demonstrated experience in heavy and civil engineering construction, particularly those with expertise in concrete repair, structural reinforcement, and water intrusion mitigation in critical infrastructure settings. The project’s requirements and deliverables are clearly defined, and the work will contribute to the long-term operational safety and resilience of the Tionesta Creek Lake Intake Tower.