B100 Child Development Center Repairs

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

DCSO RICHMOND DIVISION #1

Contract Value

Not provided

Codes & Classification
Solicitation Number

SP470326Q0050

NAICS

236220 - Commercial and Institutional Building Construction

Classification Code

Z2AA

Additional Details
Set Aside

SBA

Place of Performance

Richmond, Virginia, UNITED STATES

SourceSAM
Documents5
The Defense Logistics Agency (DLA), under the Department of Defense, has issued a combined synopsis/solicitation for the B100 Child Development Center (CDC) Repairs at Defense Supply Center Richmond (DSCR), located in Richmond, Virginia. This procurement, identified by solicitation number SP4703-26-Q-0050, seeks qualified small business contractors to perform commercial and institutional building construction services, specifically targeting exterior improvements to the CDC facility. Purpose and Scope: The primary objective of this project is to enhance the safety, accessibility, and functionality of the Child Development Center’s exterior areas. Over time, the existing concrete slabs in the playground and certain walkway sections have deteriorated and become uneven, presenting significant trip hazards for children and staff. Additionally, the parking lot striping has faded, leading to confusion and improper use of designated spaces. The scope of work includes replacing approximately 1,800 square feet of concrete slabs in the playground, removing and replacing a wooden grate section in the walkway with concrete, and re-striping the parking lot. All concrete work must adhere to American Concrete Institute (ACI) standards. Key Requirements and Deliverables: - Replacement of deteriorated playground concrete slabs (approx. 1,800 SF). - Removal and replacement of the wooden grate section in the walkway with concrete. - Saw cutting the perimeter of existing 4" thick WWF-reinforced concrete using a wet concrete saw; contractor may use the exterior hose bibb for water supply, but must install an approved vacuum breaker (backflow prevention device). - Parking lot blacking out and re-striping to be performed on weekends to avoid facility traffic. - All work within the CDC must be completed during operating hours (Monday–Friday, 6:00 AM–6:00 PM). - Compliance with Department of Labor Wage Determination for Chesterfield County, VA. - Adherence to site security and accountability measures: the sidewalk by the main gate must remain open and free of hazards throughout the project, and all contractor personnel must sign in and out daily due to the active nature of the CDC. Contracting Entity and Location: The contracting entity is DCSO Richmond Division #1, a federal office under the Defense Logistics Agency. The place of performance is Richmond, Virginia (VA), United States. The NAICS code for this procurement is 236220 (Commercial and Institutional Building Construction), with a small business size standard of $45 million. The Product Service Code is Z2AA. Procurement Type and Set-Aside: This solicitation is issued as a Request for Quotes (RFQ) in accordance with FAR Part 12 for commercially available services. The contract will be awarded as a firm-fixed price agreement with a 90-day period of performance from the issuance of the Notice to Proceed. The acquisition is set aside 100% for small businesses under SBA guidelines. Partial proposals will not be accepted. Special Considerations: - Contractors must own, possess, or control a bona fide place of business within 120 miles of DSCR, with at least one full-time employee. The address must be included in the bid. - Past performance will be evaluated as part of technical acceptability, with data pulled from CPARS and SPRS. - Contractors must be registered in the System for Award Management (SAM) prior to award. - Limitations on subcontracting apply as per SBA regulations, with specific percentages outlined for services and construction. - Security and access to DSCR require pre-enrollment in the Defense Biometric Identification System (DBIDS), with QR codes provided to the project manager for site visit access. Timeline and Points of Contact: - Site visit scheduled for June 11, 2026, at 10:00 AM at Building 100. Contact Luis Ramos Martinez at (804) 807-5612 or [email protected] for site access coordination. - Questions are due by end of day June 15, 2026, via email to [email protected]. - Quotes are due by end of day June 19, 2026. - Primary point of contact for this requirement is Justin Jones ([email protected], 445-737-8626). Reference Documents: - Attachment 1: Statement of Work (SOW) for detailed scope and requirements. - Attachment 2: Wage Determination. - Attachment 3: Addendum to RFP – Offer Requirements. Contractors interested in this opportunity should review the full solicitation and attachments via the SAM.gov link provided (https://sam.gov/opp/7b5384dbfc8f412f89371f9f2711f8f3/view), ensure compliance with all requirements, and confirm their eligibility as a small business with a qualifying place of business within the specified radius. The project is designed to deliver lasting improvements to the CDC’s exterior, prioritizing safety, accessibility, and operational efficiency for the facility’s users.