MAINTENANCE & REPAIR (M&R) FOR BUILDING 205 SSO LOCKER AT U.S. COAST GUARD SECTOR NEW YORK

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

CEU PROVIDENCE(000G1)

Contract Value

Not provided

Codes & Classification
Solicitation Number

70Z0G126SNY0002NP

NAICS

236220 - Commercial and Institutional Building Construction

Classification Code

Z2NZ

Additional Details
Set Aside

SBA

Place of Performance

Staten Island, New York, UNITED STATES

SourceSAM
This presolicitation notice, issued under procurement identifier 70Z0G126SNY0002NP, pertains to the planned maintenance and repair (M&R) project for Building 205’s Safety & Security Operations (SSO) Locker at the U.S. Coast Guard Sector New York, located in Staten Island, New York. The contracting entity is CEU Providence, operating under the Department of Homeland Security, U.S. Coast Guard. The primary points of contact for this opportunity are Nadine Provost (Contract Specialist, [email protected], 206-820-5607) and Simon W. Leung (Contracting Officer, [email protected], 571-610-2795). **Purpose and Scope:** The project is a design/build requirement aimed at addressing significant water intrusion and structural issues affecting the 3,200 square foot SSO locker, which serves as the sole ready gear locker and wet room facility at Fort Wadsworth Coast Guard Facility, Building 205. The intended outcome is to restore the facility to a watertight, energy-efficient, and fully functional state, ensuring the safety and operational readiness of Coast Guard personnel. **Key Requirements and Objectives:** The scope of work encompasses both design and construction services. Design services include the development of construction documents, stamped and approved by registered professionals in New York, covering the repair and replacement of the building envelope (roof membrane and flashing), demolition and replacement of the faux brick façade down to the metal stud framing, and replacement of entry stairs, doors, and railings. The design must address water intrusion through roof and wall surfaces, specify exterior wall assemblies (including vinyl siding systems and insulation), and ensure maximum energy efficiency through proper sealing of windows, penetrations, and sills. Construction requirements involve incidental interior and exterior general construction, including demolition and reconstruction of wall and flooring assemblies, painting, and finish work. The contractor must restore all disturbed surfaces to pre-construction condition. Temporary facilities are required: two trailers providing equivalent space to the current locker room, with full utility services (natural gas, electricity, water, sanitary waste), and temporary power service. Trailer T-1 must include full bathroom facilities, while Trailer T-2 serves as a locker room without water service. The design/build firm is responsible for engaging qualified architectural and engineering professionals, conducting site visits and field investigations, answering all design and construction questions, approving technical submittals, and performing final inspections and punch list generation. **Contracting and Procurement Details:** - **Procurement Type:** Sealed bidding procedures in accordance with FAR Part 14. - **Set-Aside:** 100% set-aside for small businesses under SBA guidelines. - **NAICS Code:** 236220 (Commercial and Institutional Building Construction), with a small business size standard of $45.0 million. - **Product Service Code:** Z2AZ (Repair or Alteration of Other Administration Facilities and Service Buildings). - **Estimated Price Range:** $1,000,000 to $5,000,000. - **Bid Guarantee:** 20% required; performance and payment bonds will be mandatory. - **Period of Performance:** 147 days for design, 120 days for construction, totaling 267 calendar days. - **Place of Performance:** Staten Island, New York, USA. **Solicitation and Submission Information:** The solicitation, including specifications and drawings, will be posted to SAM.gov on or about June 10, 2026. The bid opening is tentatively scheduled for July 14, 2026, at 2:00 p.m. local time in Warwick, RI. Bids must remain valid for at least 90 days. All documents and amendments will be available electronically; paper copies will not be issued. Vendors must register in the System for Award Management (SAM.gov) to be eligible for contract award. Interested parties are encouraged to register for notifications and as interested vendors on SAM.gov. **Special Considerations:** This notice is for informational purposes only and does not constitute an invitation for bid. Bids submitted in response to this presolicitation notice will not be accepted or evaluated. The government reserves the right to cancel the solicitation at any time, and no reimbursement will be made for costs associated with responding to this notice. **Constant Elements:** Throughout the contract lifecycle, the project will remain focused on the repair and restoration of Building 205’s SSO locker, adherence to federal procurement and small business set-aside requirements, compliance with specified NAICS and PSC codes, and the necessity for qualified, registered design professionals. The place of performance, contracting entity, and core objectives will not change. For further information, contractors should refer to the official SAM.gov posting (Opportunity ID: 91840be9e63a4618a125ca5350e6b1aa) and direct inquiries to the listed contacts.