Percutaneous Coronary Intervention (PCI) Intra - Aortic Balloon Pumps

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

W40M MRC0 WEST

Contract Value

Not provided

Codes & Classification
Solicitation Number

W81K0026QA153

NAICS

339112 - Surgical and Medical Instrument Manufacturing

Classification Code

6515

Additional Details
Set Aside

SDVOSBC

Place of Performance

Fort Bliss, Texas, UNITED STATES

SourceSAM
Documents2
The Department of Cardiology at William Beaumont Army Medical Center (WBAMC), located at Fort Bliss, Texas, is soliciting offers for the procurement of two (2) Intra-Aortic Balloon Circulatory Assist Units to support high-risk Percutaneous Coronary Intervention (PCI) procedures. This acquisition is critical to ensuring that WBAMC’s CATH LAB is equipped with state-of-the-art mechanical support devices, which are essential for adult cardiovascular interventions requiring immediate circulatory assistance. Historically, the facility performs approximately six high-risk PCI cases per month that necessitate such devices. The scope of this procurement encompasses the delivery, installation, and training associated with the latest FDA-approved intra-aortic balloon pump (IABP) systems. The selected contractor must provide devices that are free from unresolved FDA recalls and represent the most current model available. Key technical requirements include a portable, stand-alone system designed exclusively for adult use, with both automatic and manual operational modes. The system must feature a high-resolution, color touchscreen monitor (up to 14 inches) capable of displaying multiple parameters, including ECG, arterial and balloon pressures, trigger and operational modes, and pressure values. Additional specifications include balloon volume adjustment in 0.5cc increments, timing adjustments in 1-second increments, and comprehensive signal outputs (ECG, arterial pressure, fluid-filled transducer, fiberoptic sensor). The system must also support auto condensation removal, robust alarm notifications for a range of operational issues, multiple disposable and refillable helium cylinders, backup battery capability, print functionality, and a history log for up to 100 alarms. A maximum pump rate of 200 beats per minute is required. Contractors must be authorized dealers, distributors, or resellers of the proposed system and are expected to provide a warranty in accordance with the Original Equipment Manufacturer (OEM) standards. The initial provision of Test, Measurement, and Diagnostic Equipment (TMDE) necessary for servicing the units is also required. Two copies of the operator/user manual must be supplied. Comprehensive training is a mandatory deliverable. The contractor will conduct onsite clinical staff training at WBAMC, offering both morning and afternoon sessions, and must provide a signed attendance roster upon completion. Training will cover proper IABP placement and monitoring, troubleshooting, patient care specific to IABP use, and hands-on console practice. Additionally, onsite training for two clinical engineers is required, with tuition provided for any offsite training. Installation must be coordinated with the Healthcare Technology Management section at WBAMC within five business days of contract award. The installer must be an authorized OEM representative and is responsible for all tools, equipment, and materials necessary for installation, as well as the removal and disposal of packaging and waste. Access to Fort Bliss and WBAMC requires adherence to specific security and safety protocols, including providing company identification, obtaining a safety briefing, and submitting a copy of the company safety program. Delivery of the equipment is required within 45 calendar days from contract award, with no partial deliveries permitted. The contractor must ensure all shipments are properly marked and must notify the contracting officer representative three business days prior to delivery, providing tracking information. Deliveries are to be made during standard business hours, and the contractor is responsible for offloading and inside delivery to the designated location. This procurement is classified under NAICS code 339112 (Surgical and Medical Instrument Manufacturing) and Product Service Code 6515. It is set aside for Service-Disabled Veteran-Owned Small Business Concerns (SDVOSBC), reflecting the government’s commitment to supporting veteran-owned enterprises. The contracting activity is managed by W40M MRC0 WEST, a federal office under the Department of the Army, Department of Defense. Interested parties should direct inquiries to the primary contact, Elizabeth Orloski, at [email protected]. The solicitation is active, with responses due by May 29, 2026, at 11:05. Full details and attachments are available via the official SAM.gov opportunity listing (Opportunity ID: a0c6131dd1bb402581c01c7e724b303a). This opportunity is well-suited for contractors with experience in supplying advanced cardiovascular support equipment, who can meet stringent regulatory, training, and installation requirements, and who qualify under the SDVOSBC set-aside.