3 Phase Power Supply Test System

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

DCSO-COLUMBUS-DIVISION-2

Contract Value

Not provided

Codes & Classification
Solicitation Number

SP4706-26-Q-00XX

NAICS

334516 - Analytical Laboratory Instrument Manufacturing

Classification Code

6640

Additional Details
Set Aside

NONE

Place of Performance

Columbus, Ohio, UNITED STATES

SourceSAM
The Defense Logistics Agency (DLA), through its DCSO-Columbus Division 2 office, has issued a Sources Sought notice seeking qualified contractors capable of providing two advanced 3 Phase Power Supply Test Systems for the Defense Supply Center Columbus (DSCC) in Columbus, Ohio. This procurement is classified under NAICS code 334516 (Analytical Laboratory Instrument Manufacturing) and Product Service Code 6640, with no set-aside restrictions, making it open to all capable vendors. The primary objective of this acquisition is to furnish, deliver, and support two distinct power supply test systems—one rated at 18kVA and the other at 1kVA—both capable of supplying DC, single-phase (1Φ), and three-phase (3Φ) power from DC up to 5kHz. These systems are intended to enhance the DLA Product Test Center’s capabilities in testing and analyzing power supply equipment, supporting a range of waveform outputs (sinusoidal, square wave, and arbitrary waveform) with high accuracy and low distortion. The systems must be new (not refurbished), and each must be accompanied by a comprehensive operating manual. Key technical requirements include: - The 18kVA system must operate from a single 480V/3Φ delta hard-wired disconnect, while the 1kVA system should require only a standard 120V/1Φ 20A outlet. - Both systems must achieve at least 0.15% accuracy, maintain distortion levels below 0.3% at 50/60Hz and under 1% above these frequencies, and provide a power factor of no less than 0.98. - Voltage resolution must be at least 0.1V. - Each system must be delivered with a NIST Traceable Calibration Certificate and an ISO 17025 accredited calibration certificate, including data and uncertainties. - All necessary cables, sub-equipment, and accessories for reliable operation are to be included. - The systems must be mounted on wheeled frames for mobility and sized to fit through a standard commercial double door (approximately 83”H x 70”W). In addition to the core systems, the contractor must provide: - GPIB, Ethernet, and USB interfaces for system connectivity. - Two Windows 11 PCs, fully equipped with all required peripherals, hardware, ports, and permanently licensed software for system control. - Eight hours of on-site training and setup to ensure proper installation and user proficiency. - An optional extended warranty and multi-year service contract offering. Delivery is required within 30 days from the date of award, with all shipping costs included in the contract price. The contractor must notify the government when the instrument is ready for delivery. The place of performance and delivery is the Defense Supply Center Columbus, specifically to the DLA Product Test Center (Bldg 11-7, TE Lab). This notice is for market research purposes and does not constitute a solicitation. Interested parties are encouraged to review the full notice and respond by the specified deadline. The contracting activity is the Department of Defense, Defense Logistics Agency, with Tyler Merkle as the primary point of contact ([email protected], 614-693-1666). Contractors with experience in manufacturing or supplying advanced laboratory power supply test systems, and who can meet the stringent technical and delivery requirements, are encouraged to consider this opportunity. The procurement is not set aside for small businesses or any other category, and all responsible sources may respond. For further details and to monitor updates, interested vendors should refer to the official notice on SAM.gov (Opportunity ID: 0235a2d7fa2247c89934e54ddfeeeacc).