Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
250-NETWORK CONTRACT OFFICE 10 (36C250)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C25026B0042
NAICS
238220 - Plumbing, Heating, and Air-Conditioning Contractors
Classification Code
Z2DA
Additional Details
The Department of Veterans Affairs (VA), through its Network Contract Office 10, has issued a solicitation for the replacement of dual duct boxes on the second floor of the Cincinnati VA Medical Center, under project number 539-21-201. This procurement, identified by IFB number 36C25026B0042, seeks qualified contractors specializing in plumbing, heating, and air-conditioning (NAICS 238220) to undertake a comprehensive mechanical upgrade within an active healthcare environment.
The primary objective of this project is to replace existing dual duct boxes on the second floor, ensuring improved HVAC performance and compliance with current standards. The scope of work encompasses not only the mechanical replacement but also associated tasks such as asbestos and lead-based paint abatement, coordination of life safety requirements, and restoration of affected finishes. Contractors are expected to adhere strictly to VA specifications and OSHA regulations, particularly regarding hazardous material handling and abatement procedures.
Key requirements and deliverables include:
- Replacement of dual duct boxes as detailed in the project drawings and specifications.
- Abatement of asbestos-containing materials (ACM) and lead-based paint (LBP) where impacted by the work, with specific attention to white-painted plaster walls containing 480 ppm lead and ACM associated with mechanical demolition.
- Coordination of all abatement activities to occur during weekends (Friday 8PM to Monday 6AM), with corridors reopened for normal operations outside these hours. Full closure of both sides of corridors during abatement is permissible with proper coordination.
- Restoration of wall finishes to a level 5 standard, with paint as an acceptable finish if matching attic stock is unavailable.
- Compliance with all life safety requirements, as existing smoke and fire walls are indicated on the provided drawings.
- Use of Procore construction management software is acceptable for project administration.
Contractors should note several logistical considerations:
- There is no guaranteed laydown space for materials; contractors must plan accordingly.
- Power is available on site, but dumpster locations must be coordinated with the Contracting Officer’s Representative (COR).
- No contractor parking is permitted on the VA campus.
- The superintendent may serve in a dual capacity as the Site Safety and Health Officer (SSHO).
The solicitation is classified under Product Service Code Z2DA (Repair or Alteration of Hospitals and Infirmaries) and is managed by the federal office of the Department of Veterans Affairs. The primary point of contact for this opportunity is Ronald T. Heidemann ([email protected]).
Interested contractors should review all solicitation documents and attachments (19 available via SAM.gov) for detailed requirements and submit their responses by June 16, 2026, at 17:06. The opportunity remains active and is accessible through the official SAM.gov portal at https://sam.gov/opp/ffad897dbe654dc3ad38419120845d10/view.
This procurement represents a significant opportunity for contractors with expertise in mechanical systems replacement, hazardous material abatement, and healthcare facility renovations. Firms must be prepared to operate within the constraints of an occupied medical center, coordinate closely with VA representatives, and maintain strict adherence to safety and regulatory standards throughout the project lifecycle.