LAN HVAC Replacement

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

INTERNAT. BOUNDARY AND WATER COMM.

Contract Value

Not provided

Codes & Classification
Solicitation Number

FY261222006

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Classification Code

N041

Additional Details
Set Aside

SBA

Place of Performance

El Paso, Texas, UNITED STATES

SourceSAM
Documents4
The International Boundary and Water Commission, United States Section (IBWC), is soliciting quotes from qualified small businesses for the replacement of the Local Area Network (LAN) HVAC system at its headquarters located at 4191 N. Mesa, El Paso, Texas 79902. This procurement, identified by solicitation number FY261222006, is issued as a combined synopsis/solicitation in accordance with FAR Subpart 12.6 for commercial items, and constitutes the only solicitation for this requirement. No separate written solicitation will be provided. **Purpose and Scope:** The primary objective of this procurement is to replace the existing HVAC system serving the server room at the IBWC El Paso headquarters. The intended outcome is to ensure reliable, efficient cooling for critical IT infrastructure, maintaining optimal environmental conditions for the LAN equipment. The project encompasses the removal of the current system and installation of a new air-cooled HVAC unit with a cooling capacity of 23 kW (approximately 6.5 tons), as clarified in recent modifications to the solicitation. The new system must meet all performance, environmental, and operational criteria specified in the Statement of Work (SOW). **Key Requirements and Deliverables:** - The replacement HVAC system must be equivalent to or exceed the technical specifications outlined in the SOW. While the Liebert PX023UA1A809KM model is referenced, the agency will accept equivalent alternatives, provided they are fully compatible with existing infrastructure and supported by documentation verifying equivalency. - The indoor evaporator unit is located in the server room on the second floor, accessible via elevator (4000 lbs. capacity, 4x7 ft door, 4ft W x 6.5ft L x 7.3ft H) or stairs. The outdoor condenser is situated on the third-floor roof, with crane access available only from the southwest corner of the building. - The existing line sets are operational and may be reused, subject to proper flushing and cleaning. If replacement is required, offerors should reference site visit details for approximate lengths. - Electrical connections: The indoor unit is fed from Panel H1 (Circuit 20,22,24, 480 volts) located in the first-floor supply room near the west exit. The unit is currently connected to a triple 50A breaker, with wiring and conduit installed circa 2018/2019. Offerors must confirm the adequacy of the existing electrical infrastructure and specify any required upgrades. - Integration with building controls: The HVAC unit is managed via a built-in console in the server room and is not part of the Building Automation System (BMS). - All work must comply with the CLIN structure and SOW provided as attachments. Quotes must be submitted on an "all or none" basis. **Evaluation Criteria:** The contract will be awarded to the lowest price technically acceptable (LPTA) offeror whose proposal meets all IBWC requirements. Evaluation factors include: - Technical acceptability: Offerors must demonstrate their technical approach through a narrative detailing their plan of action, equipment selection, key team members, and project schedule. - Past performance: Offerors must provide at least three references for similar projects, including contact information and brief project descriptions. - Price: Only technically acceptable offers will be considered for award. **Procurement Details and Special Considerations:** - This solicitation is a 100% Small Business Set Aside under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors), with a $19.0 million SBA size standard. The Product Service Code is N041 (Installation of Equipment—Refrigeration, Air Conditioning, and Air Circulating Equipment). - Offerors must include their active UEI (Unique Entity Identifier) in their submission. - Quotes must remain valid for 90 days. - The due date for offers is May 6, 2026, at 3:00 pm MST. Questions must be submitted via email to Angelica Baca ([email protected]) by 3:00 pm on May 1, 2026; late questions may not be answered. - A single site visit for all interested vendors is scheduled for April 24th from 9:00 to 10:00 a.m. Attendance is strongly encouraged, as this is the only opportunity for an on-site assessment. The point of contact for site visit logistics is Sebastian Calderon ([email protected]). - Offerors must include a completed copy of FAR provision 52.212-3 (Offeror Representations and Certifications—Commercial Items) with their offer, or complete paragraph (b) if annual representations and certifications are available in SAM.gov. **Contracting Entity and Contact Information:** - Contracting Entity: International Boundary and Water Commission, US-Mexico (Federal Office) - Primary Contact: Angelica Baca ([email protected]) - Secondary Contact: Seone Michael Jones ([email protected]) - Contracting Officer’s Representative (COR): Antonio Almaguer (do not contact directly; all questions to Angelica Baca) **Constant Elements Throughout Contract Lifecycle:** - The place of performance will remain El Paso, Texas. - The requirement is strictly for small businesses under NAICS 238220. - The technical specifications, operational criteria, and compatibility requirements for the HVAC system will remain unchanged. - The evaluation criteria (technical approach, past performance, price) and submission requirements (UEI, representations and certifications) will be constant. **Summary for Contractors:** This opportunity is well-suited for small businesses specializing in HVAC installation and replacement, particularly those with experience in server room cooling systems and commercial air conditioning projects. Contractors must be able to demonstrate technical expertise, provide references for similar work, and ensure compliance with all specified requirements. The project involves logistical challenges such as rooftop condenser placement and integration with existing electrical and mechanical infrastructure, making site visit attendance essential for accurate quoting. All communications and submissions must be directed to the designated contracting officials, and adherence to the solicitation timeline and requirements is critical for consideration. For full details, attachments, and updates, refer to the official notice at [SAM.gov](https://sam.gov/opp/c423f57605814a1d826c29ad1be046c8/view).