6515--RFI EQUIPMENT - Brand Name or Equal to INFUSION DEVICE ANALYZER
Key Dates
Due Date
-
Posted Date
-
Agency & Value
Agency
242-NETWORK CONTRACT OFFICE 02 (36C242)
Contract Value
Not provided
Codes & Classification
Solicitation Number
36C24226Q0535
NAICS
334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
Classification Code
6515
Additional Details
Documents2
The Department of Veterans Affairs (VA), through its VISN 02 Network Contracting Office (NCO 02), is conducting a Sources Sought/Request for Information (RFI) to identify qualified vendors capable of supplying two (2) four-channel Infusion Device Analyzers, brand name or equal to the referenced model, for the Hudson Valley Healthcare System. This RFI is issued strictly for market research and planning purposes in accordance with FAR 12 and does not constitute a solicitation or a commitment to award a contract.
Purpose and Scope:
The primary objective of this procurement is to equip the Castle Point VA Medical Center in Wappingers Falls, New York, with advanced Infusion Device Analyzers. These analyzers are essential for the preventive maintenance and performance verification of infusion pumps used throughout the facility, ensuring compliance with IEC60601-2-24 standards and supporting patient safety. The analyzers will enable biomedical engineers to test multiple infusion devices simultaneously, automate testing workflows, and enhance the efficiency and accuracy of documentation. This acquisition is critical for regulatory compliance and for minimizing downtime of vital infusion equipment.
Key Requirements and Deliverables:
Vendors must be able to provide two (2) four-channel Infusion Device Analyzers that meet or exceed the following salient characteristics:
- Workflow Automation: Integrated OneQA software for automated testing and documentation.
- Multi-Channel Testing: Capability to test up to four infusion pumps simultaneously.
- Measurement Accuracy: Flow range of 0–3000 mL/h (steady), 0–1500 mL/h (peristaltic); flow accuracy of ±(1% + 0.005 mL/h) at <500 mL/h, otherwise ±2%; volume range of 0–100,000 mL with 0.001 mL resolution.
- Occlusion Testing: Peak pressure range from -200 to +2600 mmHg with accuracy of ±(1% + 5 mmHg).
- Bolus & PCA Verification: Support for bolus flow and volume testing.
- Compliance: Must meet IEC60601-2-24 and IEC61010-1 standards.
- User Interface: Large 10-inch touchscreen with intuitive controls.
- Connectivity: USB-C for PC communication and wireless capability for field testing.
- Data Storage: Capacity for over 10,000 measurements, with the ability to upload pictures and instructions.
- Physical Specifications: Approximate dimensions of 95 mm × 210 mm × 260 mm and weight of ~3.8 kg.
- Power Requirements: 19 V DC, 3 A.
- Safety: Compliance with IEC and EMC standards; no additional VA security accreditation required.
No optional items are required with these analyzers. Delivery is expected within one week of award to the Castle Point Campus, 41 Castle Point Road, Wappingers Falls, NY 12590. Upon delivery, the VA Contracting Officer’s Representative (COR) will inspect the items.
Contracting Entity and Classification:
- Contracting Office: 242-Network Contract Office 02 (NCO 02), Department of Veterans Affairs
- Place of Performance: Wappingers Falls, New York, USA
- NAICS Code: 334510 – Electromedical and Electrotherapeutic Apparatus Manufacturing (size standard: 1,250 employees)
- Product Service Code: 6515 – Medical and Surgical Instruments, Equipment, and Supplies
Procurement Type and Special Considerations:
This notice is a Sources Sought/RFI and not a solicitation. The VA is seeking information from all business sizes and types, including Service Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), HUBZone, Woman Owned Small Businesses (WOSB), and large businesses. The VA expresses a preference for domestically manufactured equipment where available. Respondents are encouraged to provide information regarding their business size, manufacturing or distribution capabilities, and whether the proposed solution is available on any federal supply schedules (e.g., GSA, NASA SEWP).
Privacy and Security:
Contractors must comply with all applicable VA privacy and confidentiality statutes and regulations. While no VA security accreditation is required for this equipment, all personnel must be aware of their responsibilities regarding the protection of VA sensitive information and incidental disclosures.
Response Instructions:
Interested parties should submit their responses via email to Sanchez Reid at [email protected] by April 27, 2026, at 4:00 PM EST. Telephone inquiries will not be accepted. Responses should include company information, business size and status, manufacturing or distribution details, capabilities relative to the salient characteristics, and any relevant federal contract numbers. General pricing information is encouraged for market research purposes only.
This RFI is for information gathering only; it does not obligate the government to issue a solicitation or award a contract. If a solicitation is issued, it will be announced separately, and interested parties must respond to that solicitation independently.
For further details, refer to the official notice at: https://sam.gov/opp/330b8546b91c4408b05f1b3abab201c2/view