Y1DA--630A4-26-401 MRI AHU Modification

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

242-NETWORK CONTRACT OFFICE 02 (36C242)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24226R0060

NAICS

236220 - Commercial and Institutional Building Construction

Classification Code

Y1DA

Additional Details
Set Aside

None

Place of Performance

-

SourceSAM
The Department of Veterans Affairs, through its Network Contract Office 02 (NCO 02), has issued a solicitation for the modification of the MRI Air Handling Unit (AHU) at facility 630A4, under project number 26-401. This procurement, identified by solicitation number 36C24226R0060 and classified under NAICS code 236220 (Commercial and Institutional Building Construction), seeks qualified contractors to undertake HVAC modifications specifically tailored to the MRI suite’s requirements. The scope of work centers on the installation and configuration of fan coil units within the corridor adjacent to the MRI area. The contract documents originally specified six surface-mounted, 18,000 BTU/h chilled water fan coil units. However, concerns were raised regarding the protrusion of these units into the hallway, which could pose both aesthetic challenges and potential safety hazards for pedestrian traffic. In response, the VA has provided two acceptable alternatives for contractors to consider: Option A: Installation of six ceiling-mounted fan coil units, each rated at 18,000 BTU/h. This option maintains the desired equipment redundancy and distributed airflow, equivalent to the original wall-mounted design. Contractors should note that due to ceiling constraints, these units may not be equally spaced along the corridor. Clearance requirements are specified: a minimum of 6 inches below the ceiling for airflow, with the evaporator fan coil unit height at approximately 12-14 inches. In an 8-foot-high corridor, this would leave at least 76 inches (6 feet 3 inches) of clearance beneath the units, with greater clearance possible in taller corridors. Option B: Installation of three ceiling-mounted fan coil units of higher capacity, spaced evenly along the corridor, to provide equivalent total cooling capacity as the original six-unit design. The intended outcome of this project is to ensure optimal climate control and air distribution in the MRI suite, while addressing safety and aesthetic concerns in the corridor. Contractors are expected to deliver a solution that meets the VA’s technical requirements, adheres to specified clearance and spacing guidelines, and does not incur additional costs to the VA for the proposed alternatives. This solicitation is active and open for responses, with a posting date of August 26, 2026, and a response deadline of August 28, 2026. Interested parties should direct inquiries and submissions to the primary contact, Kimberly A Gomez, at [email protected]. The opportunity is listed on SAM.gov under Opportunity ID b1097a4265794540b53e23fffb553541, where additional attachments may be available for review. Contractors evaluating this opportunity should ensure their capabilities align with commercial and institutional building construction, particularly HVAC modifications in healthcare environments. The procurement is managed by a federal contracting office, and all work must comply with VA standards and requirements. No set-aside or special considerations are specified in the provided information. The project’s core elements—fan coil unit installation, corridor clearance, and adherence to VA-approved alternatives—will remain constant throughout the contract lifecycle.
Documents22