6632--Automated Osmolality Testing

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

248-NETWORK CONTRACT OFFICE 8 (36C248)

Contract Value

Not provided

Codes & Classification
Solicitation Number

36C24826Q0407

NAICS

334516 - Analytical Laboratory Instrument Manufacturing

Classification Code

6632

Additional Details
Set Aside

None

Place of Performance

-

SourceSAM
Documents1
The Department of Veterans Affairs (VA), through its 248-Network Contract Office 8, has issued an award notice for the procurement of fully automated osmolality testing systems to support the Tampa VA Healthcare Network (TVAHCN), specifically the Department of Pathology and Laboratory Medicine Service (P&LMS) located at 13,000 Bruce B. Downs Blvd., Tampa, Florida 33612. This procurement, classified under NAICS code 334516 (Analytical Laboratory Instrument Manufacturing) and Product Service Code 6632, is designed to enhance the laboratory’s capacity for precise, efficient, and compliant osmolality testing. **Purpose and Scope** The primary objective of this procurement is to furnish, install, and support two state-of-the-art, fully automated osmometer systems—one Advanced Instruments OsmoPRO® MAX Automated Osmometer and one Advanced Instruments Osmo1® Single-Sample Micro-Osmometer. The contractor is responsible for the complete delivery, installation, and validation of these systems, as well as comprehensive user training, ongoing maintenance, and the continuous supply of all necessary reagents, consumables, and replacement parts. The systems must be capable of interfacing with the VA’s Laboratory Information System (Vista) and/or middleware (Data Innovations), ensuring seamless data management and integration into existing laboratory workflows. **Key Requirements and Deliverables** - **Equipment and Installation:** The contractor must provide new, current-production models of the specified osmometers, ensuring all equipment meets or exceeds detailed technical specifications for accuracy, precision, capacity, and operational reliability. Installation includes in-house delivery, positioning, mounting, and connection of all equipment and associated hardware/software. - **Reagents and Consumables:** All reagents, calibrators, controls, and consumables required for operation must be supplied, with inventory sufficient for at least 30 days of testing at each location. The quality of reagents must meet proficiency standards set by the College of American Pathologists (CAP) and The Joint Commission. - **Validation and Performance Studies:** The contractor is responsible for conducting comprehensive validation studies, including assay correlations, linearity, precision, accuracy, reference range, and carryover studies, in accordance with CLSI guidelines. Statistical analysis and documentation are required to ensure the new systems meet all performance criteria. - **Training:** On-site and/or off-site training must be provided for at least two key operators per instrument at installation, with additional training slots available annually and upon hardware/software upgrades. Training covers system operation, maintenance, troubleshooting, and data management. - **Maintenance and Support:** Full preventive and corrective maintenance is included, with all labor, parts, and travel at the contractor’s expense. On-site technical support is available Monday through Friday, 8am–5pm (excluding federal holidays), with a maximum three-day response time. Telephone support is available 24/7, with one-hour callback and three-day on-site response for service calls. - **Data Management:** The systems must support robust data management, including record storage, result reporting, calibration, and quality control documentation. All necessary software, licenses, and hardware (servers, printers, UPS, etc.) are to be provided. - **Regulatory Compliance:** All equipment and materials must comply with FDA regulations and industry standards. Only FDA-approved instruments are acceptable, and all products must have a minimum one-year shelf life unless otherwise specified by the FDA. - **Emergency Supply Handling:** The contractor must provide expedited (within 24 hours) delivery of reagents and consumables in the event of defective supplies or supply chain failures, at no additional cost to the government. - **Ownership and Removal:** Equipment remains the property of the contractor and must be removed at contract end or upon replacement, with all associated costs borne by the contractor. The VA retains the hard drive to ensure data security. **Contracting Entity and Contact Information** - **Contracting Office:** 248-NETWORK CONTRACT OFFICE 8 (36C248), Department of Veterans Affairs - **Location:** Tampa, Florida - **Primary Contact:** David Griganavicius - Email: [email protected] - Phone: 813-631-2812 **Procurement Type and Special Considerations** This is an award notice for a federal procurement, with no explicit set-aside requirements or small business preferences indicated in the notice. The contract emphasizes turnkey delivery, ongoing compliance with technical and regulatory standards, and a high level of contractor accountability for equipment performance, supply continuity, and user support throughout the contract lifecycle. **Summary for Contractors** This opportunity is suited for contractors with proven expertise in analytical laboratory instrument manufacturing, particularly those with experience supplying, installing, and supporting advanced osmolality testing systems in clinical environments. The contract demands robust logistical capabilities for reagent and consumable supply, technical proficiency in system validation and integration, and a strong track record in regulatory compliance and customer support. Contractors must be prepared to deliver comprehensive, uninterrupted service and support, ensuring the VA laboratory’s operational continuity and compliance with all applicable standards. For further details or to review the full award documentation, interested parties may refer to the official notice at [SAM.gov Opportunity ID 0800787480284ad59fea612f6c67b0fc](https://sam.gov/opp/0800787480284ad59fea612f6c67b0fc/view).