NOTICE OF INTENT - Sole Source Johnson Controls Electronic Security System for the Chilled Water Plant Replacement and Utility Upgrades Project at the VA West Haven Campus

Key Dates
Due Date

-

Posted Date

-

Agency & Value
Agency

W2SD ENDIST NEW ENGLAND

Contract Value

Not provided

Codes & Classification
Solicitation Number

W912WJ26X1B68

NAICS

-

Classification Code

-

Additional Details
Set Aside

None

Place of Performance

West Haven, Connecticut, UNITED STATES

SourceSAM
The U.S. Army Corps of Engineers, New England District (W2SD ENDIST NEW ENGLAND), has issued a Special Notice of Intent regarding a sole source procurement for the Johnson Controls Electronic Security System (ESS) as part of the Chilled Water Plant Replacement and Utility Upgrades Project at the VA West Haven Campus in West Haven, Connecticut. This procurement is conducted under the authority of FAR 6.103-1, which allows for brand name requirements when necessary to meet the Government’s needs. The primary objective of this procurement is to ensure the seamless integration and continued operation of the campus-wide security system, which is currently standardized on Johnson Controls equipment. The scope of work includes the provision and installation of access control card readers, door contacts, controllers, motion sensors, video surveillance cameras, digital video recorders (DVRs), and duress buttons. These components are essential for maintaining the security infrastructure, with servers located in the data center and control panels/power supplies distributed throughout local Telecommunications Rooms (TRs). A critical requirement of this project is the full integration of all security system components into the existing Johnson Controls platform. The system is centrally monitored in the Security Control Center, necessitating that all new and replacement devices communicate seamlessly with the current infrastructure to support single-point monitoring. This integration is vital for ensuring the safety and security of patients and staff at the VA West Haven Campus, as the use of disparate or non-compatible systems could compromise the effectiveness of security operations. The notice emphasizes that security systems are proprietary and typically do not interoperate with equipment from other manufacturers. Therefore, to maintain system integrity and avoid risks associated with fragmented security coverage, the Government intends to specify Johnson Controls as the sole acceptable manufacturer for this requirement. This notice is not a solicitation for competitive proposals but serves as a market research tool to identify any other qualified sources capable of meeting the stringent integration requirements inherent to the Johnson Controls system. Interested parties who believe they can fulfill these requirements are invited to submit responses within 15 days of the notice posting. All responses will be considered for the purpose of determining whether to allow alternate system manufacturers; however, the final decision rests solely with the Government. The place of performance for this project is the VA West Haven Campus, located in West Haven, Connecticut. The contracting activity is managed by the U.S. Army Corps of Engineers, New England District, under the Department of Defense, Department of the Army. For further information or to submit a response, interested parties should contact Tyler Maryak ([email protected]) and copy Erin Bradley ([email protected]), referencing “W912WJ26X1B68 – JCI ESS” in the subject line. This procurement is classified as a sole source, brand name requirement, with no set-aside or special considerations indicated. The opportunity remains active, and all relevant details can be found on the official SAM.gov listing (Opportunity ID: 2c358a9a8ca6412785a2a2ab6c5a81bc). Contractors with expertise in Johnson Controls security systems and the ability to deliver fully integrated solutions are encouraged to review the notice and consider responding if their capabilities align with the outlined requirements.